Tuning of weighting factors is a very complex task in the implementation of conventional finite set predictive torque control (FS-PTC) for 3L-NPC inverter fed IM drive. The choice of these weighting factors strongly influences the control objectives such as flux, torque and neutral point voltage (NPV). Moreover, the computational burden is high as all 27 switching states are enumerated for the evaluation of a cost function involving multiple objectives. To reduce the complexity of the conventional FS-PTC, this paper proposes a high-efficient single-vector-based predictive flux control (PFC) for an IM drive fed by a three-level NPC inverter. The proposed cascaded predictive flux and NPV control evaluates 13 vectors for outer predictive flux control and 2 switching states for the inner predictive NPV control. It significantly reduces the computational load as the number of enumerations is reduced by more than 50%. The nontrivial process of weighting factor calculation is no longer required. The complexity reduction and the elimination of weighting factors are achieved without sacrificing the transient and steady-state performances in terms of torque and stator flux responses, total harmonic distortion of stator currents, NPV variation and average switching frequency, compared to the conventional method as verified by experimental results.
4 February 2020 in IEEE Transactions on Industry Applications
Conventional finite control set (FCS) predictive load-voltage control for four-leg inverters features simplification in digital implementation compared to its complex counterpart, 3D-SVM. However, the FCS approach is typically characterized by a variable switching frequency, low steady-state performance, and a higher average switching frequency in the neutral leg than other three legs. To overcome these shortcomings, an online duty-cycle optimization based modulated model predictive control technique is proposed in this paper. The performance of the inverter is evaluated experimentally in terms of load voltage tracking in different operating conditions such as non-linear loads and balanced/unbalanced references. The proposed technique fulfills the requirement of a high performance converter, constant switching frequency and enhanced load voltage tracking at a lower sampling rate and thus solves the drawbacks of the conventional FCS-MPC for a four-leg inverter. Furthermore, the proposed approach can facilitate the over-modulation operation which is desirable for this type of power converters under nonlinear and unbalanced loading conditions.
8 December 2023 in IEEE Transactions on Industry Applications
This paper proposes a new framework for the deadbeat direct torque control for IPMSM. Unlike the conventional deadbeat direct torque and stator flux control (DB-DTFC), the active flux, instead of stator flux, is used as a control variable along with the torque. In the new framework of torque-active flux control, an active flux weakening (AFW) approach is proposed, which enhances the accuracy of flux weakening (FW) operation while reducing computational complexity. The accuracy in AFW operation stems from the inclusion of stator resistance voltage drop. This paper also proposes a unique solution for the intersection torque of voltage and current constraints in flux weakening operation. The complexity of solving higher-order nonlinear equations for intersection torque is overcome by the proposed solution. In addition, maximum torque per active flux (MTPAF) control up to the base speed is derived in the new control plane. The proposed MTPAF control is inherently simplified than the conventional MTPA control. Theoretical analysis and extensive experimental results demonstrate the effectiveness of the proposed method