1 July 2026 in Arteriosclerosis, Thrombosis, and Vascular Biology
MBMireia Bragulat-Arévalo
+6
BACKGROUND: Most abdominal aortic aneurysms (AAA) present intraluminal thrombus (ILT). Whether its role is detrimental or protective for AAA evolution and patients outcomes is debated. 18 F-fluorodeoxyglucose positron emission tomography analysis in patients with AAA has shown contradictory results and has not widely explored ILT. The aim of this cross-sectional study was to investigate the colocalized association between 18 F-fluorodeoxyglucose and ILT presence and characteristics in AAA. METHODS: Consecutive patients with infrarenal AAA were prospectively enrolled and underwent positron emission tomography/magnetic resonance imaging. From the abdominal aorta segmentation, an aortic wall volume was defined and discretized into 28 standardized aortic patches, permitting colocalized interpatient and intrapatient analyses. The target-to-background ratio (TBR) was extracted in each patch, and extremely low (coldspots) and high (hotspots) absorption areas were computed. Local AAA diameters and ILT characteristics were computed in each patch. Linear mixed-effect models were used to test the association between AAA and ILT characteristics and 18 F-fluorodeoxyglucose uptake. RESULTS: Thirty-six patients (median age, 73 [interquartile range, 68–77] years, 31 [86.1%] men) completed the protocol. The AAA maximum diameter was 49.6 (45.0–56.2) mm, and most patients (28 [77.8%]) presented ILT. Patients with thrombus presented higher coldspot area and lower hotspot area ( P <0.001). Patches in nondilated regions presented higher TBR compared with AAA patches ( P <0.001), which showed a negative association of TBR with local diameter ( β =−0.006) and thrombus presence ( β =−0.003). TBR decreased with increased ILT coverage ( β =−0.002), while coldspot area increased ( β =0.046). In both the ILT and thrombus-covered wall, TBR decreased with increasing ILT thickness. CONCLUSIONS: Decreased metabolic activity as per 18-fluorodeoxyglucose positron emission tomography is observed in the AAA wall compared with the nondilated abdominal region. This effect is exacerbated by local thrombus presence and thickness, suggesting that ILT contributes to the further degradation of the aortic wall in the diseased region.
29 December 2025 in medRxiv
Background: Aortic valve calcification (AVC), as measured by gold-standard computed tomography (CT) Agatston score, provides an anatomic assessment of aortic stenosis (AS) severity and is a key predictor of AS progression and need for valve replacement. AVC detection and quantification from transthoracic echocardiography (TTE) could expand AS early diagnosis and risk stratification, currently limited by CT availability and radiation exposure. Methods: A multi-view video-based deep learning framework was developed using 1166 TTE aortic valve videos from 187 TTE studies acquired in 110 patients with available AVC score by CT. EchoAVC architecture includes a feature extraction model followed by a quality-aware model that aggregates video-level information to obtain patient-level predictions for AVC detection and quantification (score). The framework was validated internally with 173 TTE studies from 86 patients across seven centres, and externally using 430 TTE studies from 280 patients across four different centres. The associations between EchoAVC estimations and AS severity, progression, and need for aortic valve replacement were examined. Results: EchoAVC demonstrated excellent performance in AVC detection (AUROC 0.98, accuracy 94.4%), and quantification (R = 0.64) in the external multi-centre testing set. EchoAVC score was correlated with echocardiographic AS severity descriptors, including aortic valve mean pressure gradient (ρ = 0.749) and peak velocity (ρ = 0.757), and predicted future increase in mean pressure gradient (ρ = 0.382), peak velocity (ρ = 0.433) and calcium score by CT (ρ = 0.650). In 361 patients followed for a median of 3.8 years, 139 underwent aortic valve replacement. Baseline presence and extent of AVC as predicted by EchoAVC showed strong risk-stratification power for aortic valve replacement, remarkably in line with those obtained by CT, and incremental over TTE AS descriptors. EchoAVC was further tested in routine clinical practice images, confirming strong associations with AS severity and progression, including stratification for incident AS in previously unaffected individuals (p<0.001). Conclusions: EchoAVC enables accurate and non-invasive detection and quantification of AVC, offering substantial diagnostic and prognostic value for aortic stenosis progression and need for valve replacement. This technique holds promise as a scalable tool for early detection and clinical management of aortic valve stenosis. Clinical Perspective: What Is New?: * Aortic valve calcification can be detected and quantified on standard, two-dimensional transthoracic echocardiography * EchoAVC score is associated with echocardiographic metrics of aortic stenosis severity * EchoAVC predicts progressive increase in aortic stenosis severity and need for aortic valve replacement What Are the Clinical Implications?: * This openly available deep learning framework can be used to estimate aortic valve calcium in patients at risk of or presenting aortic stenosis to predict aortic stenosis progression * EchoAVC may help identify patients likely to have high aortic valve calcium and prioritize them for confirmatory CT assessment, thereby supporting earlier identification of calcific aortic valve disease in clinical pathways.