Dominik Oberthür

Dominik Oberthür

Auto-generated profile, based on publicly available information

Dominik Oberthür

Center for Free-Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestraße 85, 22607 Hamburg, Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2021 in Science
Verified
Journal Article
Open access
PDF file
SGSebastian Guenther
Sebastian Guenther
PRPatrick Y. A. Reinke
Patrick Y. A. Reinke
YFYaiza Fernández-García
Yaiza Fernández-García
JLJulia Lieske
Julia Lieske
TLThomas J. Lane
Thomas J. Lane
AMAlke Meents
Alke Meents
A large-scale screen to target SARS-CoV-2: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) genome is initially expressed as two large polyproteins. Its main protease, M pro , is essential to yield functional viral proteins, making it a key drug target. Günther et al. used x-ray crystallography to screen more than 5000 compounds that are either approved drugs or drugs in clinical trials. The screen identified 37 compounds that bind to M pro . High-resolution structures showed that most compounds bind at the active site but also revealed two allosteric sites where binding of a drug causes conformational changes that affect the active site. In cell-based assays, seven compounds had antiviral activity without toxicity. The most potent, calpeptin, binds covalently in the active site, whereas the second most potent, pelitinib, binds at an allosteric site. Science , this issue p. 642

9 October 2017 in IUCrJ
Verified
Journal Article
Open access
PDF file
KBKenneth R. Beyerlein
Kenneth R. Beyerlein
DDDennis Dierksmeyer
Dennis Dierksmeyer
VMValerio Mariani
Valerio Mariani
MKManuela Kuhn
Manuela Kuhn
ISIosifina Sarrou
Iosifina Sarrou
DODominik Oberthuer
Dominik Oberthuer
Unravelling the interaction of biological macromolecules with ligands and substrates at high spatial and temporal resolution remains a major challenge in structural biology. The development of serial crystallography methods at X-ray free-electron lasers and subsequently at synchrotron light sources allows new approaches to tackle this challenge. Here, a new polyimide tape drive designed for mix-and-diffuse serial crystallography experiments is reported. The structure of lysozyme bound by the competitive inhibitor chitotriose was determined using this device in combination with microfluidic mixers. The electron densities obtained from mixing times of 2 and 50 s show clear binding of chitotriose to the enzyme at a high level of detail. The success of this approach shows the potential for high-throughput drug screening and even structural enzymology on short timescales at bright synchrotron light sources.

1 December 2023 in Science
Verified
Journal Article
Closed access
NCNina-Eleni Christou
Nina-Eleni Christou
VAVirginia Apostolopoulou
Virginia Apostolopoulou
DMDiogo V. M. Melo
Diogo V. M. Melo
MRMatthias Ruppert
Matthias Ruppert
AFAlisia Fadini
Alisia Fadini
TLThomas J. Lane
Thomas J. Lane
Photolyase is an enzyme that uses light to catalyze DNA repair. To capture the reaction intermediates involved in the enzyme’s catalytic cycle, we conducted a time-resolved crystallography experiment. We found that photolyase traps the excited state of the active cofactor, flavin adenine dinucleotide (FAD), in a highly bent geometry. This excited state performs electron transfer to damaged DNA, inducing repair. We show that the repair reaction, which involves the lysis of two covalent bonds, occurs through a single-bond intermediate. The transformation of the substrate into product crowds the active site and disrupts hydrogen bonds with the enzyme, resulting in stepwise product release, with the 3′ thymine ejected first, followed by the 5′ base.

1 May 2025 in Nature Methods
Verified
Journal Article
Closed access
PDF file
ABAmir Banari
Amir Banari
ASAmit K. Samanta
Amit K. Samanta
Anna MunkeAnna Munke
Anna Munke
TLTim Laugks
Tim Laugks
SBSasa Bajt
Sasa Bajt
CSCarolin Seuring
Carolin Seuring

17 August 2019 in IUCrJ
Verified
Journal Article
Open access
PDF file
ATA. Tolstikova
A. Tolstikova
MLM. Levantino
M. Levantino
OYOleksandr M. Yefanov
Oleksandr M. Yefanov
VHVincent Hennicke
Vincent Hennicke
PFP. Fischer
P. Fischer
AMA. Meents
A. Meents
Reliable sample delivery and efficient use of limited beam time have remained bottlenecks for serial crystallography (SX). Using a high-intensity polychromatic X-ray beam in combination with a newly developed charge-integrating JUNGFRAU detector, we have applied the method of fixed-target SX to collect data at a rate of 1 kHz at a synchrotron-radiation facility. According to our data analysis for the given experimental conditions, only about 3 000 diffraction patterns are required for a high-quality diffraction dataset. With indexing rates of up to 25%, recording of such a dataset takes less than 30 s.

31 October 2022 in IUCrJ
Verified
Journal Article
Open access
PDF file
KZKara A Zielinski
Kara A Zielinski
APAndreas Prester
Andreas Prester
Hina AndaleebHina Andaleeb
Hina Andaleeb
SBSoi Bui
Soi Bui
OYOleksandr M. Yefanov
Oleksandr M. Yefanov
DODominik Oberthuer
Dominik Oberthuer
Serial crystallography at conventional synchrotron light sources (SSX) offers the possibility to routinely collect data at room temperature using micrometre-sized crystals of biological macromolecules. However, SSX data collection is not yet as routine and currently takes significantly longer than the standard rotation series cryo-crystallography. Thus, its use for high-throughput approaches, such as fragment-based drug screening, where the possibility to measure at physiological temperatures would be a great benefit, is impaired. On the way to high-throughput SSX using a conveyor belt based sample delivery system – the CFEL TapeDrive – with three different proteins of biological relevance (Klebsiella pneumoniae CTX-M-14 β-lactamase, Nectria haematococca xylanase GH11 and Aspergillus flavus urate oxidase), it is shown here that complete datasets can be collected in less than a minute and only minimal amounts of sample are required.