Oleksandr M. Yefanov

Dr. Oleksandr M. Yefanov

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2015 in Nature
Verified
Journal Article
Open access
PDF file
YKYanyong Kang
Yanyong Kang
XZX. Edward Zhou
X. Edward Zhou
XGXiang Gao
Xiang Gao
YHYuanzheng He
Yuanzheng He
WLWei Liu
Wei Liu
HXH. Eric Xu
H. Eric Xu
G-protein-coupled receptors (GPCRs) signal primarily through G proteins or arrestins. Arrestin binding to GPCRs blocks G protein interaction and redirects signalling to numerous G-protein-independent pathways. Here we report the crystal structure of a constitutively active form of human rhodopsin bound to a pre-activated form of the mouse visual arrestin, determined by serial femtosecond X-ray laser crystallography. Together with extensive biochemical and mutagenesis data, the structure reveals an overall architecture of the rhodopsin–arrestin assembly in which rhodopsin uses distinct structural elements, including transmembrane helix 7 and helix 8, to recruit arrestin. Correspondingly, arrestin adopts the pre-activated conformation, with a ∼20° rotation between the amino and carboxy domains, which opens up a cleft in arrestin to accommodate a short helix formed by the second intracellular loop of rhodopsin. This structure provides a basis for understanding GPCR-mediated arrestin-biased signalling and demonstrates the power of X-ray lasers for advancing the frontiers of structural biology.

5 December 2014 in Science
Verified
Journal Article
Closed access
PDF file
JTJason Tenboer
Jason Tenboer
Shibom BasuShibom Basu
Shibom Basu
NZNadia Zatsepin
Nadia Zatsepin
KPKanupriya Pande
Kanupriya Pande
DMDespina Milathianaki
Despina Milathianaki
MSMarius Schmidt
Marius Schmidt
Serial femtosecond crystallography using ultrashort pulses from x-ray free electron lasers (XFELs) enables studies of the light-triggered dynamics of biomolecules. We used microcrystals of photoactive yellow protein (a bacterial blue light photoreceptor) as a model system and obtained high-resolution, time-resolved difference electron density maps of excellent quality with strong features; these allowed the determination of structures of reaction intermediates to a resolution of 1.6 angstroms. Our results open the way to the study of reversible and nonreversible biological reactions on time scales as short as femtoseconds under conditions that maximize the extent of reaction initiation throughout the crystal.

6 May 2016 in Science
Verified
Journal Article
Open access
PDF file
KPKanupriya Pande
Kanupriya Pande
CHChristopher D. M. Hutchison
Christopher D. M. Hutchison
GGGerrit Groenhof
Gerrit Groenhof
AAAndy Aquila
Andy Aquila
JRJosef S. Robinson
Josef S. Robinson
MSMarius Schmidt
Marius Schmidt
Visualizing a response to light: Many biological processes depend on detecting and responding to light. The response is often mediated by a structural change in a protein that begins when absorption of a photon causes isomerization of a chromophore bound to the protein. Pande et al. used x-ray pulses emitted by a free electron laser source to conduct time-resolved serial femtosecond crystallography in the time range of 100 fs to 3 ms. This allowed for the real-time tracking of the trans-cis isomerization of the chromophore in photoactive yellow protein and the associated structural changes in the protein. Science , this issue p. 725

1 May 2015 in Cell
Verified
Journal Article
Closed access
HZHaitao Zhang
Haitao Zhang
HUHamiyet Unal
Hamiyet Unal
CGCornelius Gati
Cornelius Gati
GHGye Won Han
Gye Won Han
WLWei Liu
Wei Liu
VCVadim Cherezov
Vadim Cherezov

29 March 2016 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
TWThomas A. White
Thomas A. White
VMValerio Mariani
Valerio Mariani
WBWolfgang Brehm
Wolfgang Brehm
OYOleksandr M. Yefanov
Oleksandr M. Yefanov
ABAnton Barty
Anton Barty
HCHenry Chapman
Henry Chapman
CrystFEL is a suite of programs for processing data from `serial crystallography' experiments, which are usually performed using X-ray free-electron lasers (FELs) but also increasingly with other X-ray sources. The CrystFEL software suite has been under development since 2009, just before the first hard FEL experiments were performed, and has been significantly updated and improved since then. This article describes the most important improvements which have been made to CrystFEL since the first release version. These changes include the addition of new programs to the suite, the ability to resolve `indexing ambiguities' and several ways to improve the quality of the integrated data by more accurately modelling the underlying diffraction physics.

30 May 2014 in IUCrJ
Verified
Journal Article
Open access
FSFrancesco Stellato
Francesco Stellato
DODominik Oberthür
Dominik Oberthür
MLMengning Liang
Mengning Liang
RBRichard Bean
Richard Bean
CGCornelius Gati
Cornelius Gati
HCHenry Chapman
Henry Chapman
A new approach for collecting data from many hundreds of thousands of microcrystals using X-ray pulses from a free-electron laser has recently been developed. Referred to as serial crystallography, diffraction patterns are recorded at a constant rate as a suspension of protein crystals flows across the path of an X-ray beam. Events that by chance contain single-crystal diffraction patterns are retained, then indexed and merged to form a three-dimensional set of reflection intensities for structure determination. This approach relies upon several innovations: an intense X-ray beam; a fast detector system; a means to rapidly flow a suspension of crystals across the X-ray beam; and the computational infrastructure to process the large volume of data. Originally conceived for radiation-damage-free measurements with ultrafast X-ray pulses, the same methods can be employed with synchrotron radiation. As in powder diffraction, the averaging of thousands of observations per Bragg peak may improve the ratio of signal to noise of low-dose exposures. Here, it is shown that this paradigm can be implemented for room-temperature data collection using synchrotron radiation and exposure times of less than 3 ms. Using lysozyme microcrystals as a model system, over 40 000 single-crystal diffraction patterns were obtained and merged to produce a structural model that could be refined to 2.1 Å resolution. The resulting electron density is in excellent agreement with that obtained using standard X-ray data collection techniques. With further improvements the method is well suited for even shorter exposures at future and upgraded synchrotron radiation facilities that may deliver beams with 1000 times higher brightness than they currently produce.