Flexible pressure sensors are indispensable components in various applications such as intelligent robots and wearable devices, whereas developing flexible pressure sensors with both high sensitivity and wide linear range remains a great challenge. Here, we present an elegant strategy to address this challenge by taking advantage of a pyramidal carbon foam array as the sensing layer and an elastomer spacer as the stiffness regulator, realizing an unprecedentedly high sensitivity of 24.6 kPa−1 and an ultra-wide linear range of 1.4 MPa together. Such a wide range of linearity is attributed to the synergy between the nonlinear piezoresistivity of the sensing layer and the nonlinear elasticity of the stiffness regulator. The great application potential of our sensor in robotic manipulation, healthcare monitoring, and human-machine interface is demonstrated. Our design strategy can be extended to the other types of flexible sensors calling for both high sensitivity and wide-range linearity, facilitating the development of high-performance flexible pressure sensors for intelligent robotics and wearable devices.
The proliferation of flexible pressure sensors has generated new demands for high-sensitivity and low-cost sensors. Here, we propose an elegant strategy to address this challenge by taking a ridge-mimicking, gradient-varying, spatially ordered microstructure as the sensing layer, with laser processing and interdigitated electrodes as the upper and lower electrode layers. Simultaneously, the entire structure is encapsulated with polyimide (PI) tape for protection, and the fabrication process is relatively feasible, facilitating easy scaling. The presented results show that the flexible pressure sensor exhibits a sensitivity of 1.65 kPa−1 across a pressure range of 0 to 1100 kPa. Furthermore, the sensor displays low hysteresis, as well as rapid response and recovery times of 62 ms and 83 ms, respectively. Finally, we demonstrate the application potential of the sensor for monitoring joint movements, especially for detecting pressure and direction in finger joints. This technology shows great potential for applications in smart robotics, wearable devices, health monitoring, and other emerging technologies.
The multiplexer plays a crucial role in the scanning process of resistive sensor arrays for data acquisition. However, it is important to note that the on-resistance of the multiplexers can impact the accuracy of the measurement results for the specific element being tested. This limitation can hinder the integrated application of resistive sensor arrays. Aiming at the typical resistive sensor array data acquisition circuit, such as zero potential method and voltage feedback method, this paper systematically analyzes the influence of the on-resistance of the multiplexer on the measurement error. Firstly, the mathematical models of the on-resistance of the multiplexer and the measurement error of the element being tested have been established. Additionally, the improved strategies for reducing the measurement error from the multiplexer have been proposed. The simulation results in Proteus not only confirm the correctness of the influence mechanism analysis, but also demonstrate that the improved strategies can minimize measurement errors caused by the multiplexer under different cases. Finally, the actual circuit based on the improved strategy has been implemented, and the corresponding experimental results show that the actual 2-D resistive sensor array data acquisition circuit has excellent measurement accuracy (below 0.3%) and shape accuracy, and further, it can accurately identify the pressure of piezoresistive sensor array. The improvement strategies proposed in this paper offer highly precise scanning techniques for large-scale resistive sensor arrays.