Background: Ultrasonography of the cardiovascular system is pivotal for hemodynamic assessment. Diastolic function is evaluated with a combination of tissue Doppler (e’ and a’) and pulsed Doppler (E and A) measures of transmitral- and mitral valve annuli velocities. However, accurate echocardiographic evaluation in the intensive care unit or perioperative setting is contingent on relative resistance to positive pressure ventilation and changes in preload. This study aimed to evaluate the effects of positive end-expiratory pressure (PEEP) and positioning on echocardiographic measures of diastolic function. Methods: The study was a prospective, randomized, crossover study. Cardiac surgery patients with ejection fraction greater than 45% and averaged e’ of 9 or more were included. Postoperatively, anesthetized patients were randomized into six combinations of PEEP (0, 6, 12 cm H2O) and positions (horizontal, Trendelenburg). At each combination, e’ (primary endpoint), a’, E, and A were obtained with transesophageal echocardiography along with left ventricular area. Image analysis was performed blinded to the protocol. Results: Thirty patients completed the study. PEEP decreased lateral e’ from 6.6 ± 3.6 to 5.3 ± 3.0 cm/s (P < 0.001) in the horizontal position and from 7.4 ± 4.2 to 6.5 ± 3.3 cm/s (P < 0.001) in Trendelenburg. Similar results were found for septal e’, a’ bilaterally and transmitral pulsed Doppler measures, and PEEP decreased left ventricular area. E/A, E/e’, and e’/a’ remained unaffected by PEEP and positioning. Conclusions: When evaluating diastolic function by echocardiography, the levels of PEEP and its effect on ventricular area have to be taken into account. In addition, this study dissuades the use of E/e’ for tracking changes in left ventricular filling pressures in cardiac surgery patients.
Acute kidney injury (AKI) is a frequent and severe complication in cardiac surgery. Normal renal function is dependent on adequate renal perfusion, which may be altered in the perioperative period. Renal perfusion can be assessed with Doppler measurement. We aimed to determine the association between Doppler measurements of renal perfusion and the development of AKI. This was a prospective, observational study of 100 patients with ≥ one risk factor for postoperative AKI undergoing open-heart surgery. Doppler ultrasound examinations were performed before surgery and on the first and fourth postoperative day. AKI was defined according to the KDIGO criteria and subdivided into mild (KDIGO stage 1) and severe AKI (KDIGO stage 2 + 3). Thirty-three patients developed AKI, 25 developed mild and eight developed severe AKI. Abnormal renal venous flow pattern on the first postoperative day was significantly associated with the development of severe AKI (OR 8.54 (95% CI 1.01; 72.2), P = 0.046), as were portal pulsatility fraction (OR 1.07 (95% CI 1.02; 1.13), P = 0.005). Point-of-care Doppler ultrasound measurements of renal perfusion are associated with the development of AKI after cardiac surgery. Renal and portal Doppler ultrasonography can be used to identify patients at high risk or very low risk of AKI after cardiac surgery.