11 January 2021 in Nature Communications
DVDavid A. M. C. van de Vijver
David A. M. C. van de Vijver
AEAnnemiek A. van der Eijk
+19
Key questions in COVID-19 are the duration and determinants of infectious virus shedding. Here, we report that infectious virus shedding is detected by virus cultures in 23 of the 129 patients (17.8%) hospitalized with COVID-19. The median duration of shedding infectious virus is 8 days post onset of symptoms (IQR 5–11) and drops below 5% after 15.2 days post onset of symptoms (95% confidence interval (CI) 13.4–17.2). Multivariate analyses identify viral loads above 7 log10 RNA copies/mL (odds ratio [OR] of 14.7 (CI 3.57-58.1; p < 0.001) as independently associated with isolation of infectious SARS-CoV-2 from the respiratory tract. A serum neutralizing antibody titre of at least 1:20 (OR of 0.01 (CI 0.003-0.08; p < 0.001) is independently associated with non-infectious SARS-CoV-2. We conclude that quantitative viral RNA load assays and serological assays could be used in test-based strategies to discontinue or de-escalate infection prevention and control precautions.
27 May 2020 in Transplant International
TGthe Rotterdam Transplant Group
the Rotterdam Transplant Group
+6
Background Solid organ transplant (SOT) recipients may be at risk for severe COVID‐19. Data on the clinical course of COVID‐19 in immunosuppressed patients are limited and the effective treatment strategy for these patients is unknown. Methods We describe our institutional experience with COVID‐19 in SOT. Demographic, clinical and treatment data were extracted from the electronic patient files. Results A total of 23 SOT transplant recipients suffering from COVID‐19 were identified (n = 3 heart; n =15 kidney; n = 1 kidney‐after‐heart; n = 3 lung and n = 1 liver transplant recipient). The presenting symptoms were similar to non‐immunocompromised patients Eighty‐three percent (19/23) of the patients required hospitalization but only two of these were transferred to the intensive care unit. Five patients died from COVID‐19; all had high Clinical Frailty scores. In four of these patients, mechanical ventilation was deemed futile. In 57% of patients, the immunosuppressive therapy was not changed and only 3 patients were treated with chloroquine. Most patients recovered without experimental anti‐viral therapy. Conclusions Modification of the immunosuppressive regimen alone could be a therapeutic option for SOT recipients suffering from moderate to severe COVID‐19. Pre‐existent frailty is associated with death from COVID‐19.
19 June 2022 in The Journal of Heart and Lung Transplantation
CLCoretta C. van Leer-Buter
Coretta C. van Leer-Buter
+7
Concerns have been raised on the impact of coronavirus disease (COVID-19) on lung transplant (LTx) patients. The aim of this study was to evaluate the transplant function pre- and post-COVID-19 in LTx patients. Data were retrospectively collected from LTx patients with confirmed COVID-19 from all 3 Dutch transplant centers, between February 2020 and September 2021. Spirometry results were collected pre-COVID-19, 3- and 6-months post infection. Seventy-four LTx patients were included. Forty-two (57%) patients were admitted, 19 (26%) to the intensive care unit (ICU). The in-hospital mortality was 20%. Twelve out of 19 ICU patients died (63%), a further 3 died on general wards. Patients with available spirometry (78% at 3 months, 65% at 6 months) showed a significant decline in mean forced expiratory volume in 1 second (FEV1) (ΔFEV1 138 ± 39 ml, p = 0.001), and forced vital capacity (FVC) (ΔFVC 233 ±74 ml, p = 0.000) 3 months post infection. Lung function improved slightly from 3 to 6 months after COVID-19 (ΔFEV1 24 ± 38 ml; ΔFVC 100 ± 46 ml), but remained significantly lower than pre-COVID-19 values (ΔFEV1 86 ml ± 36 ml, p = 0.021; ΔFVC 117 ± 35 ml, p = 0.012). FEV1/FVC was > 0.70. In LTx patients COVID-19 results in high mortality in hospitalized patients. Lung function declined 3 months after infection and gradually improved at 6 months, but remained significantly lower compared to pre-COVID-19 values. The more significant decline in FVC than in FEV1 and FEV1/FVC > 70%, suggested a more restrictive pattern.
16 March 2022 in The Journal of Heart and Lung Transplantation
Serological responses to COVID-19 vaccination are diminished in recipients of solid organ transplants, especially in lung transplant recipients (LTR), probably as result of immunosuppressive treatment. There is currently no marker of immunosuppression that can be used to predict the COVID-19 vaccination response. Here, we study whether torque tenovirus (TTV), a highly prevalent virus can be used as an indicator of immunosuppression. The humoral response to the mRNA 1273 vaccine was assessed in 103 LTR, who received a transplant between 4 and 237 months prior to vaccination, by measuring Spike (S)-specific IgG levels at baseline, 28 days after first, and 28 days after the second vaccination. TTV loads were determined by RT-PCR and Pearson's correlation coefficient was calculated to correlate serological responses to TTV load. Humoral responses to COVID-19 vaccination were observed in 41 of 103 (40%) LTR at 28 days after the second vaccination. Sixty-two of 103 (60%) were non-responders. Lower TTV loads at baseline (significantly) correlated with higher S-specific antibodies and a higher percentage of responders. Lower TTV loads also strongly correlated with longer time since transplantation, indicating that participants with lower TTV loads were longer after transplantation. This study shows a better humoral response to the SARS-CoV-2 vaccine in subjects with a lower TTV load pre-vaccination. In addition, TTV load correlates with the time after transplantation. Further studies on the use of TTV load in vaccination efficacy studies in immunocompromised cohorts should provide leads for the potential use of this marker for optimizing vaccination response.
26 January 2020 in Transplant International
The aim of this study was to investigate whether there is an impact of donation rates on the quality of lungs used for transplantation and whether donor lung quality affects post‐transplant outcome in the current LAS era. All consecutive adult LTx performed in Eurotransplant (ET) between January 2012 and December 2016 were included (N=3053). Donors used for LTx in countries with high donation rate were younger (42% vs. 33% ≤ 45 years, p<0.0001), were less often smokers (35% vs. 46%, p<0.0001), had more often clear chest X‐rays (82% vs. 72%, p<0.0001), had better donor oxygenation ratio's (20% vs. 26% with PaO2/FiO2 ≤ 300 mmHg, p<0.0001) and had better lung donor score values (LDS) (28% vs. 17% with LDS=6, p<0.0001) compared to donors used for LTx in countries with low donation rate. Survival rates for the groups LDS =6 and ≥7 at 5 years were 69.7% and 60.9% (p=0.007). Lung donor quality significantly impacts on long‐term patient survival. Countries with a low donation rate are more oriented to using donor lungs with a lesser quality compared to countries with a high donation rate. Instead of further stretching donor eligibility criteria, the full potential of the donor pool should be realized.
19 September 2022 in The Journal of Heart and Lung Transplantation
There is a need for reliable biomarkers for the diagnosis of chronic lung allograft dysfunction (CLAD). In this light, we investigated the diagnostic value of exhaled breath analysis using an electronic nose (eNose) for CLAD, CLAD phenotype, and CLAD stage in lung transplant recipients (LTR). We performed eNose measurements in LTR with and without CLAD, visiting the outpatient clinic. Through supervised machine learning, the diagnostic value of eNose for CLAD was assessed in a random training and validation set. Next, we investigated the diagnostic value of the eNose measurements combined with known risk factors for CLAD. Model performance was evaluated using ROC-analysis. We included 152 LTR (median age 60 years, 49% females), of whom 38 with CLAD. eNose-based classification of patients with and without CLAD provided an AUC of 0.86 in the training set, and 0.82 in the validation set. After adding established risk factors for CLAD (age, gender, type of transplantation, time after transplantation and prior occurrence of acute cellular rejection) to a model with the eNose data, the discriminative ability of the model improved to an AUC of 0.94 (p = 0.02) in the training set and 0.94 (p = 0.04) in the validation set. Discrimination between BOS and RAS was good (AUC 0.95). Discriminative ability for other phenotypes (AUCs ranging 0.50-0.92) or CLAD stages (AUC 0.56) was limited. Exhaled breath analysis using eNose is a promising novel biomarker for enabling diagnosis and phenotyping CLAD. eNose technology could be a valuable addition to the diagnostic armamentarium for suspected graft failure in LTR.