Johanna Tapias-Rivera

Johanna Tapias-Rivera

Auto-generated profile, based on publicly available information

Johanna Tapias-Rivera

Universidad de Santander, Facultad de Ciencias Médicas y de la Salud, Instituto Masira, Bucaramanga, Santander, Colombia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2023 in Acta Tropica
Verified
Journal Article
Closed access
JTJohanna Tapias-Rivera
Johanna Tapias-Rivera
JGJuan David Gutiérrez
Juan David Gutiérrez

13 October 2025 in PLOS Neglected Tropical Diseases
Verified
Journal Article
Open access
PDF file
JRJohanna Tapias Rivera
Johanna Tapias Rivera
RMRuth Martínez-Vega
Ruth Martínez-Vega
WQWendy Lorena Quintero-García
Wendy Lorena Quintero-García
DTDayana Sofía Torres-Martínez
Dayana Sofía Torres-Martínez
AMAngela Liliana Monroy-Díaz
Angela Liliana Monroy-Díaz
JGJuan David Gutiérrez-Torres
Juan David Gutiérrez-Torres
The World Health Organization considers cutaneous leishmaniasis (CL) to be one of the most important neglected tropical diseases (NTDs). The application of geostatistical models, in conjunction with sociodemographic and environmental factors, enables the understanding of disease epidemiology and facilitates the implementation of targeted measures and effective case management. This research aimed to evaluate the association between climatic, sociodemographic, and socioeconomic factors with the monthly CL incidence rate at the municipality level in Colombia from 2007 to 2021. An ecological study was conducted, including laboratory-confirmed notifications of CL reported in municipalities located below 1,700 meters above sea level through the National Public Health Surveillance System. Climate data were sourced from NASA, and sociodemographic and socioeconomic variables were obtained from the National Planning Department. Hierarchical spatio-temporal regression models within a Bayesian framework were used to analyze the monthly CL. A total of 121,828 cases of CL were analyzed, with an annual median of 7,605 cases. Standardized incidence rates (SIR) ranged from 0 to 16,072 per 100,000 population (median: 105.7; IQR: 46.7-419). Eight of the 11 studied factors were associated with the monthly cases of CL: rainfall, urban dimension, and Venezuelan migration were associated with a decrease in CL cases, while qualitative housing deficit, internal migration, the multidimensional poverty index, the index of unmet basic needs, and forest coverage were associated with an increase in CL cases. CL incidence in Colombia fluctuated during the study period, with high spatial heterogeneity linked to climatic, sociodemographic. and socioeconomic factors. These findings highlight the necessity for customized territorial approaches to the prevention and control of CL, emphasizing the importance of considering municipal characteristics and aligning strategies with the Colombian Strategic Plan for CL.

13 June 2024 in Heliyon
Verified
Journal Article
Open access
JGJuan Gutiérrez
Juan Gutiérrez
JTJohanna Tapias-Rivera
Johanna Tapias-Rivera
Leptospirosis is a global zoonotic disease caused by spirochete bacteria of the genus Leptospira. The disease exhibits a notable incidence in tropical and developing countries, and in Colombia, environmental, economic, social, and cultural conditions favor disease transmission, directly impacting both mortality and morbidity rates. Our objective was to establish the pooled lagged effect of runoff on leptospirosis cases in Colombia. For our study, we included the top 20 Colombian municipalities with the highest number of leptospirosis cases. Monthly cases of leptospirosis, confirmed by laboratory tests and spanning from 2007 to 2022, were obtained from the National Public Health Surveillance System. Additionally, we collected monthly runoff and atmospheric and oceanic data from remote sensors. Multidimensional poverty index values for each municipality were sourced from the Terridata repository. We employed causal inference and distributed lag nonlinear models to estimate the lagged effect of runoff on leptospirosis cases. Municipality-specific estimates were combined through meta-analysis to derive a single estimate for all municipalities under study. The pooled results for the 20 municipalities suggest a lagged effect for the 0 to 2, and 0-3 months of runoff on leptospirosis when the runoff is < 120 g/m2. No effect was identified for longer lagged periods (0-1, 0 to 4, 0 to 5, and 0-6 months) or higher runoff values. Incorporation of the multidimensional poverty index into the meta-analysis of runoff contributed to the models for the lagged periods of 0-3, and 0-4 months.

6 June 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JTJohanna Tapias-Rivera
Johanna Tapias-Rivera
RMRuth Aralí Martínez-Vega
Ruth Aralí Martínez-Vega
SRSusana Román
Susana Román
RLRene Santos Luna
Rene Santos Luna
IAIrma Yvonne Amaya-Larios
Irma Yvonne Amaya-Larios
JRJosé Ramos-Castañeda
José Ramos-Castañeda
In dengue-endemic areas, transmission control is limited by the difficulty of achieving sufficient coverage and sustainability of interventions. To maximize the effectiveness of interventions, areas with higher transmission could be identified and prioritized. The aim was to identify burden clusters of Dengue virus (DENV) infection and evaluate their association with microclimatic factors in two endemic towns from southern Mexico. Information from a prospective population cohort study (2·5 years of follow-up) was used, microclimatic variables were calculated from satellite information, and a cross-sectional design was conducted to evaluate the relationship between the outcome and microclimatic variables in the five surveys. Spatial clustering was observed in specific geographic areas at different periods. Both, land surface temperature (aPR 0·945; IC95% 0·895–0·996) and soil humidity (aPR 3·018; IC95% 1·013–8·994), were independently associated with DENV burden clusters. These findings can help health authorities design focused dengue surveillance and control activities in dengue endemic areas.

23 January 2026 in PLOS Global Public Health
Verified
Journal Article
Open access
JGJuan Gutiérrez
Juan Gutiérrez
JTJohanna Tapias-Rivera
Johanna Tapias-Rivera
MHMartha Liliana Hijuelos-Cárdenas
Martha Liliana Hijuelos-Cárdenas
LMLudivia Esther Montaño-Villalba
Ludivia Esther Montaño-Villalba
Dengue fever is among the most rapidly expanding vector-borne diseases globally, with Colombia ranking among the most affected countries in the Americas. Although previous research has linked climate variability and El Niño–Southern Oscillation (ENSO) episodes to dengue dynamics, the direct causal effect of sea surface temperature (SST) in El Niño regions remains insufficiently explored. We conducted a retrospective ecological analysis using monthly laboratory-confirmed dengue cases from 1,044 Colombian municipalities (2013–2023), combined with atmospheric, oceanic, and socioeconomic data. We emulated an experimental design to estimate the effect of SST in El Niño regions 1–2, 3, 3–4, and 4 on excess dengue cases. Confounder adjustment was guided by a Directed Acyclic Graph (DAG), and causal effects were estimated using Double Machine Learning (DML) with XGBoost learners. We estimated the Average Treatment Effect (ATE) and the Conditional Average Treatment Effect (CATE) conditioned on altitude. Robustness was evaluated with refutation tests introducing random confounders, subset replacement, and placebo exposures. A total of 455,329 confirmed dengue cases were reported during the study period, peaking in 2023. The strongest association was observed for El Niño region 3, where a standard deviation increase in SST (1.24 °C) raised the probability of excess dengue cases by 6.9 percentage points (ATE = 0.069, 95% CI = 0.056 – 0.083). El Niño regions 3–4 and 4 showed slightly weaker ATE yet significant effects (6.4% and 6.2%), while El Niño region 1–2 had the lowest effect (4.6%). The CATE analysis revealed that the effects of El Niño regions 1–2 and 3 were stronger at higher altitudes; meanwhile, for El Niño regions 3–4 and 4, the effects showed a slightly negative trend, suggesting a heterogeneous effect of El Niño regions on dengue incidence in Colombia based on altitude. Robustness checks indicated the presence of residual bias, particularly when applying the subset replacement test. These findings highlight the importance of integrating oceanic monitoring into early warning systems of the disease and tailoring vector-control strategies to local ecological contexts.

1 July 2017 in Respuestas
Verified
Journal Article
Open access
PDF file
JTJohanna Tapias-Rivera
Johanna Tapias-Rivera
CCChristian Chacin-Zambrano
Christian Chacin-Zambrano
OGOscar Guarín-Villamizar
Oscar Guarín-Villamizar
JCJuan Carlos Alberto Uribe Caputi
Juan Carlos Alberto Uribe Caputi
El presente trabajo describe las características fisicoquímicas y microbiológicas del agua antes y después de ser sometidas a un proceso de esterilización en un autoclave a vapor con carga de instrumental y paquetes de vestuario quirúrgico, con el fin de establecer el potencial para el posterior sin causar ningún efecto en la validez de la carga por ciclo. Las mediciones fueron descritas por separado, antes del primer proceso de esterilización, durante la etapa de descarga y de la entrada del agua que fue utilizada para dicho proceso. Para el desarrollo del proceso, se realizaron tres tomas de muestras con agua de osmosis y 5 correspondientes al agua directamente de grifo; posterior a cada toma de muestra se tomaron en cuenta los parámetros de esterilización, resoluciones ambientales y microbiológicas. Los resultados obtenidos mostraron significancia en los diferentes puntos de toma de muestras que llevaron a concluir alteraciones en el agua de osmosis en los diferentes puntos de muestra (entrada, chaqueta y descarga) del autoclave en lo relacionado a las características fisicoquímicas del agua obtenida de los puntos analizados del autoclave. Adicionalmente se observó presencia de coliformes totales y fecales, aerobios mesófilos que indicaron que el agua no es apta para recirculación dentro del autoclave.Palabras clave: Agua, autoclave, esterilización, vapor. Abstract The present study sought to describe the physico-chemical and microbiological characteristics of the water before and after being subjected to UN sterilization process steam autoclave load packages instrumental and surgical clothes, in order to establish its potential usefulness f back without causing any effect on the validity of the charging cycle. Were the measurements described Separately, Before the sterilization process, during the discharge stage and the entry of water that was used for this process. Development Process Three samplings were carried out with osmosis water and 5 for tap water Directly From; after each sample took into account the parameters of sterilization, Environmental Resolutions and microbiological obtained significant results in the different points of Sampling leading one Conclude Disturbances osmosis water at different points Sample (input, jacket Download and) the autoclave in relation to the physico-chemical characteristics of water obtained from the Points analyzed the autoclave, likewise presence of total and fecal coliforms was observed aerobic mesophilic bacteria which indicated that water is not suitable for recirculation within the autoclave.Keywords: Water, autoclave, sterilization steam. Resumo O presente trabalho descreve as características físico-químicas e microbiológicas da água antes e depois de ser submetido a um processo de esterilização em uma autoclave de vapor carregada com instrumentos e embalagens de vestuário cirúrgico, a fim de estabelecer o potencial para o posterior sem causar qualquer efeito sobre a validade da carga por ciclo. As medidas foram descritas separadamente, antes do primeiro processo de esterilização, durante a descarga e a fase de entrada da água que foi utilizada para o referido processo. Para o desenvolvimento do processo, foram colhidas três amostras com água de osmose e 5 correspondentes à água diretamente da torneira; Após cada amostragem, foram considerados os parâmetros de esterilização, as resoluções ambientais e microbiológicas. Os resultados obtidos mostraram diferenças significativas nos pontos de amostragem que levaram à conclusão de alterações na água de osmose nos diferentes pontos de amostra (entrada, revestimento e descarga) da autoclave em relação às características físicoquímicas da água obtida das amostras. pontos da autoclave. Além disso, observou-se a presença de coliformes totais e fecais, mesófilos aeróbicos que indicaram que a água não é adequada para a recirculação dentro da autoclave.Palavras-chave: Água, autoclave, esterilização, vapor.