Vaishnavi Dhawan

Vaishnavi Dhawan

Auto-generated profile, based on publicly available information

Vaishnavi Dhawan

Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2022 in Acta Biomaterialia
Verified
Journal Article
Closed access
NKNeetu Kushwah
Neetu Kushwah
KWKevin Woeppel
Kevin Woeppel
VDVaishnavi Dhawan
Vaishnavi Dhawan
DSDelin Shi
Delin Shi
XCXinyan Cui
Xinyan Cui

15 June 2022 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
VDVaishnavi Dhawan
Vaishnavi Dhawan
XCXinyan Cui
Xinyan Cui
Due to their specific bioactivities and hydrophilic properties, carbohydrates offer potential solutions for addressing some of the limitations of the existing biomolecular approaches for neural interfacing applications.

12 September 2023 in Biomaterials
Verified
Journal Article
Closed access
KWKevin Woeppel
Kevin Woeppel
VDVaishnavi Dhawan
Vaishnavi Dhawan
DSDelin Shi
Delin Shi
XCXinyan Cui
Xinyan Cui

26 May 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
CRChethani Kalhari Ruhunage
Chethani Kalhari Ruhunage
VDVaishnavi Dhawan
Vaishnavi Dhawan
CNChaminda P. Nawarathne
Chaminda P. Nawarathne
MHMd Abdul Hoque
Md Abdul Hoque
XCXinyan Cui
Xinyan Cui
Noe AlvarezNoe Alvarez
Noe Alvarez
The demand for electrically insulated microwires and microfibers in biomedical applications is rapidly increasing. Polymer protective coatings with high electrical resistivity, good chemical resistance, and a long shelf-life are critical to ensure continuous device operation during chronic applications. As soft and flexible electrodes can minimize mechanical mismatch between tissues and electronics, designs based on flexible conductive microfibers, such as carbon nanotube (CNT) fibers, and soft polymer insulation have been proposed. In this study, a continuous dip-coating approach was adopted to insulate meters-long CNT fibers with hydrogenated nitrile butadiene rubber (HNBR), a soft and rubbery insulating polymer. Using this method, 4.8 m long CNT fibers with diameters of 25–66 µm were continuously coated with HNBR without defects or interruptions. The coated CNT fibers were found to be uniform, pinhole free, and biocompatible. Furthermore, the HNBR coating had better high-temperature tolerance than conventional insulating materials. Microelectrodes prepared using the HNBR-coated CNT fibers exhibited stable electrochemical properties, with a specific impedance of 27.0 ± 9.4 MΩ µm2 at 1.0 kHz and a cathodal charge storage capacity of 487.6 ± 49.8 mC cm−2. Thus, the developed electrodes express characteristics that made them suitable for use in implantable medical devices for chronic in vivo applications.

11 May 2024 in Journal of Materials Chemistry B
Verified
Journal Article
Open access
PDF file
VDVaishnavi Dhawan
Vaishnavi Dhawan
PMPaige Nicole Martin
Paige Nicole Martin
XHXiaoming Hu
Xiaoming Hu
XCXinyan Cui
Xinyan Cui
Invasive neural implants allow for high-resolution bidirectional communication with the nervous tissue and have demonstrated the ability to record neural activity, stimulate neurons, and sense neurochemical species with high spatial selectivity and resolution. However, upon implantation, they are exposed to a foreign body response which can disrupt the seamless integration of the device with the native tissue and lead to deterioration in device functionality for chronic implantation. Modifying the device surface by incorporating bioactive coatings has been a promising approach to camouflage the device and improve integration while maintaining device performance. In this work, we explored the novel application of a chondroitin sulfate (CS) based hydrophilic coating, with anti-fouling and neurite-growth promoting properties for neural recording electrodes. CS-coated samples exhibited significantly reduced protein-fouling in vitro which was maintained for up to 4-weeks. Cell culture studies revealed a significant increase in neurite attachment and outgrowth and a significant decrease in microglia attachment and activation for the CS group as compared to the control. After 1-week of in vivo implantation in the mouse cortex, the coated probes demonstrated significantly lower biofouling as compared to uncoated controls. Like the in vitro results, increased neuronal population (neuronal nuclei and neurofilament) and decreased microglial activation were observed. To assess the coating's effect on the recording performance of silicon microelectrodes, we implanted coated and uncoated electrodes in the mouse striatum for 1 week and performed impedance and recording measurements. We observed significantly lower impedance in the coated group, likely due to the increased wettability of the coated surface. The peak-to-peak amplitude and the noise floor levels were both lower in the CS group compared to the controls, which led to a comparable signal-to-noise ratio between the two groups. The overall single unit yield (% channels recording a single unit) was 74% for the CS and 67% for the control group on day 1. Taken together, this study demonstrates the effectiveness of the polysaccharide-based coating in reducing biofouling and improving biocompatibility for neural electrode devices.

19 December 2025 in Biomaterials
Verified
Journal Article
Open access
VDVaishnavi Dhawan
Vaishnavi Dhawan
BWBingchen Wu
Bingchen Wu
SNSharada Narayanan
Sharada Narayanan
DSDelin Shi
Delin Shi
YPYugma Patel
Yugma Patel
XCXinyan Cui
Xinyan Cui
Implantable microelectrode arrays (MEAs) are powerful tools for neurophysiological studies and hold tremendous potential as a key component of clinical neuroprostheses. However, their long-term efficacy is hampered by inflammatory responses to implantation. This study examines the impact of MEA substrate rigidity on neural recording quality and inflammatory tissue responses. We implanted stiff silicon-based and flexible polyimide-based MEAs with similar geometries in the deep brain region of the mouse striatum and performed weekly impedance and electrophysiological measurements over 4 weeks. The flexible MEAs demonstrated more reliable recording quality in terms of stable signal-to-noise ratio, single-unit yield, peak-to-peak amplitude, noise, and impedance, compared to the stiff probes, whose performance deteriorated over time. Endpoint histological analyses were performed to assess the glial scarring (Iba-1, GFAP), blood-brain barrier integrity (IgG), mechanosensitive ion channel expression (Piezo1), and neuronal population (NeuN and NF200) around the implant site. We found reduced microglial activation and IgG fouling within a 50-μm radius around the flexible MEAs compared to the stiff group. Additionally, a higher expression of Piezo1 was observed localized around the stiff MEA, correlating positively with increased Iba-1 and GFAP intensity. Our results show that flexible MEAs have improved device-tissue integration, indicated by lower inflammation levels and better recording stability. This research underscores the critical role of MEA substrate rigidity in influencing adverse tissue reactions, especially for deep brain regions. This understanding will improve our ability to design stable and reliable devices for chronic neural interface devices and beyond.