Kaijie Ma

Kaijie Ma

Auto-generated profile, based on publicly available information

Kaijie Ma

Department of Bioengineering Graduate School of Engineering The University of Tokyo 7‐3‐1 Hongo, Bunkyo‐ku Tokyo 113–8656 Japan

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2019 in Nature Communications
Verified
Journal Article
Open access
KMKaijie Ma
Kaijie Ma
YZYunong Zhang
Yunong Zhang
LLLe Liu
Le Liu
JXJingyu Xi
Jingyu Xi
XQXinping Qiu
Xinping Qiu
YHYonghong He
Yonghong He
Understanding spatial distribution difference and reaction kinetics of the electrode is vital for enhancing the electrochemical reaction efficiency. Here, we report a total internal reflection imaging sensor without background current interference to map local current distribution of the electrode in a vanadium redox flow battery during cyclic voltammetry (CV), enabling mapping of the activity and reversibility distribution with the spatial resolution of a single fiber. Three graphite felts with different activity are compared to verify its feasibility. In long-term cyclic voltammetry, the oxygen evolution reaction is proved to enhance activity distribution, and homogeneity of the electrode and its bubble kinetics with periodic fluctuation is consistent with the cyclic voltammetry curve, enabling the onset oxygen evolution/reduction potential determination. Higher activity and irreversibility distribution of the electrode is found in favor of the oxygen evolution reaction. This sensor has potential to detect in situ, among other processes, electrochemical reactions in flow batteries, water splitting, electrocatalysis and electrochemical corrosion.


12 July 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KMKaijie Maa
Kaijie Maa
XKXiangrong Kuang
Xiangrong Kuang
LLLe Liu
Le Liu
YZYunong Zhang
Yunong Zhang
YSYunxu Sun
Yunxu Sun
DLDongzhi Lie
Dongzhi Lie
An optimized angular total internal reflection (TIR) sensor system without sensing films is proposed to detect the state of charge (SOC) of the vanadium redox flow battery (VFB) in real time. In order to balance the pixel sensitivity and the system noise considering the pixel discreteness of the charge coupled device (CCD), the distance between the sensor chip and the CCD is adjusted to obtain the optimal refractive index (RI) resolution. The optimal RI resolution is 4.18×10−6 RIU (refractive index unit) at the distance of 257 mm with the dynamic range of 0.074 RIU. An algorithm of N-point average is utilized to further reduce the system noise and therefore the RI resolution even reaches 8.13×10−7 RIU at the optimal distance. The whole discharge process of VFB detected by the optimal TIR sensor demonstrates that during three stages (VO2+ to VO2+, VO2+ to V3+ and V3+ to V2+) of the valence state variation, the RI of the electrolyte is linear with the valence state in each stage. The valence state resolutions of three stages are successively 6.56×10−5, 10.04×10−5 and 5.35×10−5. This experiment verifies that the TIR sensor with high refractive index resolution can detect the SOC variation rate of the VFB in real time, providing research tool for kinetics of electrochemical reactions.

22 December 2020 in Physical Review A
Verified
Journal Article
Closed access
PDF file
CZChongqi Zhou
Chongqi Zhou
SZSuyi Zhong
Suyi Zhong
KMKaijie Ma
Kaijie Ma
YXYang Xu
Yang Xu
LSLixuan Shi
Lixuan Shi
YHYonghong He
Yonghong He
We propose a scheme for an ultrasensitive weak measurement system with an ultrasmall rotatory dispersion effect to measure angular rotation. Estimation of angular rotation is obtained by the shift of the center wavelength. In our scheme, we obtain a continuously adjustable coupling strength and show that our system provides a 13 times higher sensitivity of 38 840 nm/rad compared with previous work. Here we demonstrate that our scheme may offer an optimal weak value Aw in practice and outperforms conventional measurements in the presence of technical noise. The precision achieved by optimized weak value amplification (WVA) is about three times higher than that of a polarimeter. Our work extends the working regime of WVA. Its simplicity and robustness clear the way for widespread use of WVA involving measurements with commercial cameras and small signals.

24 April 2026 in Nature Energy
Verified
Journal Article
Closed access
KMKaijie Ma
Kaijie Ma
YCYu Cui
Yu Cui
YRYizhang Ren
Yizhang Ren
QLQiunan Liu
Qiunan Liu
SLSong Luo
Song Luo
RHRui Hao
Rui Hao

23 August 2021 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
STSiyi Tang
Siyi Tang
Md Shamim SarkerMd Shamim Sarker
Md Shamim Sarker
KMKaijie Ma
Kaijie Ma
HYHiroyasu Yamahara
Hiroyasu Yamahara
HTHitoshi Tabata
Hitoshi Tabata
MSMunetoshi Seki
Munetoshi Seki
The realization of ultra-low energy consumption spin wave device applications requires a material that can efficiently propagate the spin waves. Spinel-type ferrite is a promising insulator from the perspective of application in magnonic devices owing to its good crystal compatibility. In this study, thin films of spinel γ-Fe2−xAlxO3 (0 ≤ x ≤0.5) are fabricated on single-crystal MgO substrates through pulsed laser deposition. High crystalline quality and room temperature ferrimagnetism are observed in all the films. Spin wave propagation is observed in γ-Fe2−xAlxO3 films, and it is found that the spin-wave transmission properties significantly correlate with the crystallinity and magnetization of the films. The γ-Fe1.85Al0.15O3 thin film represents an excellent compromise between a sufficiently high spin-wave amplitude and long propagation distance. These results indicate that the γ-Fe2−xAlxO3 thin film is a highly promising candidate for application in spin-wave-based computing devices in the future.