1 January 2014 in International Journal of Cardiology
1 October 2018 in Revista Portuguesa de Cardiologia
To report the hemodynamic profile and short- and medium-term outcomes of Freedom Solo and Solo Smart stentless aortic valves implanted at our center. Between 2009 and 2015, all patients undergoing aortic valve replacement using Solo stentless valves at our center were enrolled. Clinical and echocardiographic follow-up was carried out six months postoperatively. Survival and major events, including structural valve deterioration and non-structural valve dysfunction, endocarditis, reoperation and stroke, were assessed through medical records or telephone interview with the referring cardiologist up to November 2015 (mean and maximum follow-up 39±22 and 78 months, respectively). Patients' (n=345) mean age was 72±8 years, 52% were female and median euroSCORE II was 2.7 (1.5-4.7). There was no intraoperative mortality and in-hospital mortality was 2.6%. Postoperatively, mean transvalvular gradient was 11.9±4.5 mmHg and effective orifice area was 1.9±0.5 cm2. Patient-prosthesis mismatch occurred in 14% but was severe in only one patient. Cumulative survival at six years was 72%. Six patients were reoperated: three due to endocarditis, two for structural prosthesis deterioration and one because of periprosthetic fistula. Five patients suffered stroke, three had medically-treated endocarditis and one had structural valve deterioration but was not considered suitable for reoperation. None of the remainder had structural valve deterioration or non-structural valve dysfunction. Solo stentless aortic valves are safe to implant, with promising clinical outcomes in short- and medium-term assessment. Moreover, they show an excellent hemodynamic performance: low transvalvular gradients, large effective orifice areas and low incidence of patient-prosthesis mismatch.
25 October 2011 in Circulation
18 November 2021 in Interactive CardioVascular and Thoracic Surgery
A 62-year-old female patient was admitted to hospital care due to an ischaemic stroke and fever of unknown origin, 6 months after a transfemoral aortic valve implantation for symptomatic aortic stenosis. Further study resulted in the diagnosis of infective aortitis, and clinical course deemed prosthesis explantation necessary. In this case report, we describe the technique used to explant the partially endothelized aortic valve and review the alternatives found in literature for safe prosthesis removal.
1 August 2019 in The Annals of Thoracic Surgery
ARAntónio Rodrigues-Sousa
+1