Magnetic resonance imaging and spectroscopic techniques are widely used in humans both for clinical diagnostic applications and in basic research areas such as cognitive neuroimaging. In recent years, new human MR systems have become available operating at static magnetic fields of 7 T or higher (≥300 MHz proton frequency). Imaging human-sized objects at such high frequencies presents several challenges including non-uniform radiofrequency fields, enhanced susceptibility artifacts, and higher radiofrequency energy deposition in the tissue. On the other side of the scale are gains in signal-to-noise or contrast-to-noise ratio that allow finer structures to be visualized and smaller physiological effects to be detected. This review presents an overview of some of the latest methodological developments in human ultra-high field MRI/MRS as well as associated clinical and scientific applications. Emphasis is given to techniques that particularly benefit from the changing physical characteristics at high magnetic fields, including susceptibility-weighted imaging and phase-contrast techniques, imaging with X-nuclei, MR spectroscopy, CEST imaging, as well as functional MRI. In addition, more general methodological developments such as parallel transmission and motion correction will be discussed that are required to leverage the full potential of higher magnetic fields, and an overview of relevant physiological considerations of human high magnetic field exposure is provided.
11 September 2014 in Magnetic Resonance in Medicine
Purpose: To develop high‐resolution electrical properties tomography (EPT) methods and investigate a gradient‐based EPT (gEPT) approach that aims to reconstruct the electrical properties (EP), including conductivity and permittivity, of an imaged sample from experimentally measured B1 maps with improved boundary reconstruction and robustness against measurement noise.Theory and Methods: Using a multichannel transmit/receive stripline head coil with acquired B1 maps for each coil element, and by assuming negligible Bz component compared to transverse B1 components, a theory describing the relationship between B1 field, EP value, and their spatial gradient has been proposed. The final EP images were obtained through spatial integration over the reconstructed EP gradient. Numerical simulation, physical phantom, and in vivo human experiments at 7 T have been conducted to evaluate the performance of the proposed method.Results: Reconstruction results were compared with target EP values in both simulations and phantom experiments. Human experimental results were compared with EP values in literature. Satisfactory agreement was observed with improved boundary reconstruction. Importantly, the proposed gEPT method proved to be more robust against noise when compared to previously described nongradient‐based EPT approaches.Conclusion: The proposed gEPT approach holds promises to improve EP mapping quality by recovering the boundary information and enhancing robustness against noise. Magn Reson Med 74:634–646, 2015.
10 September 2013 in Magnetic Resonance in Medicine
Purpose: Higher signal to noise ratio (SNR) and improved contrast have been demonstrated at ultra‐high magnetic fields (≥7 Tesla [T]) in multiple targets, often with multi‐channel transmit methods to address the deleterious impact on tissue contrast due to spatial variations in B1+ profiles. When imaging the heart at 7T, however, respiratory and cardiac motion, as well as B0 inhomogeneity, greatly increase the methodological challenge. In this study we compare two‐spoke parallel transmit (pTX) RF pulses with static B1+ shimming in cardiac imaging at 7T.Methods: Using a 16‐channel pTX system, slice‐selective two‐spoke pTX pulses and static B1+ shimming were applied in cardiac CINE imaging. B1+ and B0 mapping required modified cardiac triggered sequences. Excitation homogeneity and RF energy were compared in different imaging orientations.Results: Two‐spoke pulses provide higher excitation homogeneity than B1+ shimming, especially in the more challenging posterior region of the heart. The peak value of channel‐wise RF energy was reduced, allowing for a higher flip angle, hence increased tissue contrast. Image quality with two‐spoke excitation proved to be stable throughout the entire cardiac cycle.Conclusion: Two‐spoke pTX excitation has been successfully demonstrated in the human heart at 7T, with improved image quality and reduced RF pulse energy when compared with B1+ shimming. Magn Reson Med 70:1210–1219, 2013.
Purpose: To mitigate spatial flip angle (FA) variations under strict specific absorption rate (SAR) constraints for ultra‐high field MRI using a combination of universal parallel transmit (pTx) pulses and fast subject‐specific optimization.Methods: Data sets consisting of B0, maps, and virtual observation point (VOP) data were acquired from 72 subjects (study groups of 48/12 healthy Europeans/Asians and 12 Europeans with pathological or incidental findings) using an 8Tx/32Rx head coil on a 7T whole‐body MR system. Combined optimization values (COV) were defined as combination of spiral‐nonselective (SPINS) trajectory parameters and an energy regularization weight. A set of COV was optimized universally by simulating the individual RF pulse optimizations of 12 training data sets (healthy Europeans). Subsequently, corresponding universal pulses (UPs) were calculated. Using COV and UPs, individually optimized pulses (IOPs) were calculated during the sequence preparation phase (maximum 15 s). Two different UPs and IOPs were evaluated by calculating their normalized root‐mean‐square error (NRMSE) of the FA and SAR in simulations of all data sets. Seven additional subjects were examined using an MPRAGE sequence that uses the designed pTx excitation pulses and a conventional adiabatic inversion.Results: All pTx pulses resulted in decreased mean NRMSE compared to a circularly polarized (CP) pulse (CP = ~28%, UPs = ~17%, and IOPs = ~12%). UPs and IOPs improved homogeneity for all subjects. Differences in NRMSE between study groups were much lower than differences between different pulse types.Conclusion: UPs can be used to generate fast online‐customized (FOCUS) pulses gaining lower NRMSE and/or lower SAR values.