Teodor P. Grantcharov

Teodor P. Grantcharov

Auto-generated profile, based on publicly available information

Teodor P. Grantcharov

Department of Surgery, Clinical Excellence Research Centre, Stanford University, Stanford, CA, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Journal of Endourology
Verified
Journal Article
Closed access
Mitchell GoldenbergMitchell Goldenberg
Mitchell Goldenberg
SGS. Larry Goldenberg
S. Larry Goldenberg
TGTeodor P. Grantcharov
Teodor P. Grantcharov
Introduction: There is limited, yet compelling evidence supporting the role of surgeon technical performance in influencing patient outcomes. To date, this concept has been underexplored in endourologic procedures. We hypothesized that a surgeon's technical performance plays a role in predicting an early return to continence after robot-assisted radical prostatectomy (RARP). Materials and Methods: We conducted a retrospective, matched case–control analysis of prospectively collected unedited RARP endoscopic videos performed by a single surgeon. A blinded observer with expertise in intraoperative video analysis evaluated clinically relevant steps of RARP using the global evaluative assessment of robotic skill (GEARS) and the generic error rating tool (GERT). The primary outcome was continence status at 3 months postoperatively, defined as patient use of less than or equal to a single precautionary pad. Mann–Whitney U tests examined differences in predictor variables between cases and controls, and multivariate analysis was conducted using binary logistic regression models. Results: Twenty-four incontinent patients were matched for age, body mass index, preoperative International Prostate Symptoms Score, use of posterior/anterior hitch, prostate weight, and learning curve position. No statistically significant difference in errors between groups was observed using the GERT. On multivariate analysis, overall case GEARS score was independently predictive of 3-month continence status (odds ratios [OR] = 0.55, 95% confidence interval [CI] 0.33–0.91), as were urethrovesical anastomosis (OR = 0.70, 95% CI 0.50–0.97) and bladder neck GEARS scores (OR = 0.69, 95% CI 0.51–0.94). Conclusions: Our study generates the hypothesis that there may be a link between surgeon technical performance and functional outcomes in RARP. This relationship may have implications for the accreditation and training of future urologists and warrants further investigation.

28 February 2012 in BMC Medical Education
Verified
Journal Article
Open access
PDF file
JOJeanett Oestergaard
Jeanett Oestergaard
FBFlemming Bjerrum
Flemming Bjerrum
MMMathilde Maagaard
Mathilde Maagaard
PWPer Winkel
Per Winkel
CLChristian Rifbjerg Larsen
Christian Rifbjerg Larsen
JSJette Led Soerensen
Jette Led Soerensen
Several studies have found a positive effect on the learning curve as well as the improvement of basic psychomotor skills in the operating room after virtual reality training. Despite this, the majority of surgical and gynecological departments encounter hurdles when implementing this form of training. This is mainly due to lack of knowledge concerning the time and human resources needed to train novice surgeons to an adequate level. The purpose of this trial is to investigate the impact of instructor feedback regarding time, repetitions and self-perception when training complex operational tasks on a virtual reality simulator. The study population consists of medical students on their 4th to 6th year without prior laparoscopic experience. The study is conducted in a skills laboratory at a centralized university hospital. Based on a sample size estimation 98 participants will be randomized to an intervention group or a control group. Both groups have to achieve a predefined proficiency level when conducting a laparoscopic salpingectomy using a surgical virtual reality simulator. The intervention group receives standardized instructor feedback of 10 to 12 min a maximum of three times. The control group receives no instructor feedback. Both groups receive the automated feedback generated by the virtual reality simulator. The study follows the CONSORT Statement for randomized trials. Main outcome measures are time and repetitions to reach the predefined proficiency level on the simulator. We include focus on potential sex differences, computer gaming experience and self-perception. The findings will contribute to a better understanding of optimal training methods in surgical education. NCT01497782

20 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MEMichael Eppler
Michael Eppler
ASAref S. Sayegh
Aref S. Sayegh
MMMarissa Maas
Marissa Maas
AVAbhishek Venkat
Abhishek Venkat
SHSij Hemal
Sij Hemal
Mitchell GoldenbergMitchell Goldenberg
Mitchell Goldenberg
Intraoperative adverse events (iAEs) impact the outcomes of surgery, and yet are not routinely collected, graded, and reported. Advancements in artificial intelligence (AI) have the potential to power real-time, automatic detection of these events and disrupt the landscape of surgical safety through the prediction and mitigation of iAEs. We sought to understand the current implementation of AI in this space. A literature review was performed to PRISMA-DTA standards. Included articles were from all surgical specialties and reported the automatic identification of iAEs in real-time. Details on surgical specialty, adverse events, technology used for detecting iAEs, AI algorithm/validation, and reference standards/conventional parameters were extracted. A meta-analysis of algorithms with available data was conducted using a hierarchical summary receiver operating characteristic curve (ROC). The QUADAS-2 tool was used to assess the article risk of bias and clinical applicability. A total of 2982 studies were identified by searching PubMed, Scopus, Web of Science, and IEEE Xplore, with 13 articles included for data extraction. The AI algorithms detected bleeding (n = 7), vessel injury (n = 1), perfusion deficiencies (n = 1), thermal damage (n = 1), and EMG abnormalities (n = 1), among other iAEs. Nine of the thirteen articles described at least one validation method for the detection system; five explained using cross-validation and seven divided the dataset into training and validation cohorts. Meta-analysis showed the algorithms were both sensitive and specific across included iAEs (detection OR 14.74, CI 4.7–46.2). There was heterogeneity in reported outcome statistics and article bias risk. There is a need for standardization of iAE definitions, detection, and reporting to enhance surgical care for all patients. The heterogeneous applications of AI in the literature highlights the pluripotent nature of this technology. Applications of these algorithms across a breadth of urologic procedures should be investigated to assess the generalizability of these data.

16 March 2021 in Journal of Medical Internet Research
Verified
Journal Article
Open access
SBSylvain Boet
Sylvain Boet
CECole Etherington
Cole Etherington
SLSandy Lam
Sandy Lam
MLMaxime Lê
Maxime Lê
LPLaurie Proulx
Laurie Proulx
SSSukhbir Singh
Sukhbir Singh
Background: A large proportion of surgical patient harm is preventable; yet, our ability to systematically learn from these incidents and improve clinical practice remains limited. The Operating Room Black Box was developed to address the need for comprehensive assessments of clinical performance in the operating room. It captures synchronized audio, video, patient, and environmental clinical data in real time, which are subsequently analyzed by a combination of expert raters and software-based algorithms. Despite its significant potential to facilitate research and practice improvement, there are many potential implementation challenges at the institutional, clinician, and patient level. This paper summarizes our approach to implementation of the Operating Room Black Box at a large academic Canadian center. Objective: We aimed to contribute to the development of evidence-based best practices for implementing innovative technology in the operating room for direct observation of the clinical performance by using the case of the Operating Room Black Box. Specifically, we outline the systematic approach to the Operating Room Black Box implementation undertaken at our center. Methods: Our implementation approach included seeking support from hospital leadership; building frontline support and a team of champions among patients, nurses, anesthesiologists, and surgeons; accounting for stakeholder perceptions using theory-informed qualitative interviews; engaging patients; and documenting the implementation process, including barriers and facilitators, using the consolidated framework for implementation research. Results: During the 12-month implementation period, we conducted 23 stakeholder engagement activities with over 200 participants. We recruited 10 clinician champions representing nursing, anesthesia, and surgery. We formally interviewed 15 patients and 17 perioperative clinicians and identified key themes to include in an information campaign run as part of the implementation process. Two patient partners were engaged and advised on communications as well as grant and protocol development. Many anticipated and unanticipated challenges were encountered at all levels. Implementation was ultimately successful, with the Operating Room Black Box installed in August 2018, and data collection beginning shortly thereafter. Conclusions: This paper represents the first step toward evidence-guided implementation of technologies for direct observation of performance for research and quality improvement in surgery. With technology increasingly being used in health care settings, the health care community should aim to optimize implementation processes in the best interest of health care professionals and patients.

1 August 2020 in Physica Medica
Verified
Journal Article
Closed access
BDBart Doyen
Bart Doyen
LGLauren Gordon
Lauren Gordon
GSGilles Soenens
Gilles Soenens
KBKlaus Bacher Klaus Bacher
Klaus Bacher Klaus Bacher
PVPeter Vlerick
Peter Vlerick
IHIsabelle Van Herzeele
Isabelle Van Herzeele

1 July 2017 in Annals of Surgery
Verified
Journal Article
Closed access
PSPeter Szasz
Peter Szasz
EBEsther M. Bonrath
Esther M. Bonrath
MLMarisa Louridas
Marisa Louridas
AFAndras B. Fecso
Andras B. Fecso
BHBrett Howe
Brett Howe
TGTeodor P. Grantcharov
Teodor P. Grantcharov
The objectives of this study were to (1) create a technical and nontechnical performance standard for the laparoscopic cholecystectomy, (2) assess the classification accuracy and (3) credibility of these standards, (4) determine a trainees' ability to meet both standards concurrently, and (5) delineate factors that predict standard acquisition. Scores on performance assessments are difficult to interpret in the absence of established standards. Trained raters observed General Surgery residents performing laparoscopic cholecystectomies using the Objective Structured Assessment of Technical Skill (OSATS) and the Objective Structured Assessment of Non-Technical Skills (OSANTS) instruments, while as also providing a global competent/noncompetent decision for each performance. The global decision was used to divide the trainees into 2 contrasting groups and the OSATS or OSANTS scores were graphed per group to determine the performance standard. Parametric statistics were used to determine classification accuracy and concurrent standard acquisition, receiver operator characteristic (ROC) curves were used to delineate predictive factors. Thirty-six trainees were observed 101 times. The technical standard was an OSATS of 21.04/35.00 and the nontechnical standard an OSANTS of 22.49/35.00. Applying these standards, competent/noncompetent trainees could be discriminated in 94% of technical and 95% of nontechnical performances (P < 0.001). A 21% discordance between technically and nontechnically competent trainees was identified (P < 0.001). ROC analysis demonstrated case experience and trainee level were both able to predict achieving the standards with an area under the curve (AUC) between 0.83 and 0.96 (P < 0.001). The present study presents defensible standards for technical and nontechnical performance. Such standards are imperative to implementing summative assessments into surgical training.