Robert M. Kurtz

Robert M. Kurtz

Auto-generated profile, based on publicly available information

Robert M. Kurtz

Penn Medicine Department of Radiology, Hospital of The University of Pennsylvania, Philadelphia, Pa

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2021 in Radiology Research and Practice
Verified
Journal Article
Open access
PDF file
APAthanasios Pavlou
Athanasios Pavlou
RKRobert M. Kurtz
Robert M. Kurtz
JSJae W. Song
Jae W. Song
Accuracy is an important parameter of a diagnostic test. Studies that attempt to determine a test’s accuracy can suffer from various forms of bias. As radiology is a diagnostic specialty, many radiologists may design a diagnostic accuracy study or review one to understand how it may apply to their practice. Radiologists also frequently serve as consultants to other physicians regarding the selection of the most appropriate diagnostic exams. In these roles, understanding how to critically appraise the literature is important for all radiologists. The purpose of this review is to provide a framework for evaluating potential sources of study design biases that are found in diagnostic accuracy studies and to explain their impact on sensitivity and specificity estimates. To help the reader understand these biases, we also present examples from the radiology literature.

27 September 2024 in Rheumatology
Verified
Journal Article
Closed access
PDF file
RRRennie L Rhee
Rennie L Rhee
GBGirish Bathla
Girish Bathla
RRRyan Rebello
Ryan Rebello
RKRobert M Kurtz
Robert M Kurtz
MJMats Junek
Mats Junek
USUlrich Specks
Ulrich Specks
There are an increasing number of centers performing research on high-resolution vessel wall magnetic resonance imaging (VW-MRI) in giant cell arteritis (GCA). However, harmonized approaches to VW-MRI in GCA are lacking and are essential to performing multicentre studies. Using a data-driven, consensus-based approach, an international expert group developed a standardized MRI protocol and scoring system to advance multi-centered research in cranial GCA. A targeted literature review of VW-MRI in cranial GCA was conducted. A working group comprised of radiologists, rheumatologists, and ophthalmologists with expertise in VW-MRI and GCA reviewed the results of the literature search, presented relevant data and images from their respective centers, and then reached consensus on recommendations related to key MRI structures, MRI sequences, scoring system, and other important considerations. A total of 21 relevant articles were identified and reviewed. Based on published literature, structures to be evaluated on MRI were categorized based on anatomic location (extradural cranial, intradural cranial, and orbits) and prioritization (core vs elective). Essential and elective sequences to comprehensively image cranial and orbital structures while minimizing scan time were determined along with scoring systems to grade contrast enhancement. This report describes a standardized approach to facilitate research of VW-MRI in cranial GCA that is the result of a multi-disciplinary, international collaboration of experts in VW-MRI and/or GCA.

15 December 2022 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
RKR.M. Kurtz
R.M. Kurtz
VBV.D. Babatunde
V.D. Babatunde
JSJ.E. Schmitt
J.E. Schmitt
JBJ.R. Berger
J.R. Berger
SMS. Mohan
S. Mohan
Sarcoidosis is a multisystem granulomatous disease, with intramedullary spinal cord involvement seen in <1% of cases. This case series illustrates the clinical presentations and imaging findings of 5 patients with intramedullary spinal neurosarcoidosis occurring at sites of spondylotic spinal canal stenosis, which can be indistinguishable from spondylotic myelopathy with cord enhancement. Both entities are most common in middle-aged men and present with weeks to months of motor and sensory symptoms. On imaging, both can have focal spinal cord enhancement and longitudinally extensive signal abnormality centered at or just below the level of spinal canal stenosis. On the basis of our experience, we suggest that in patients with cord enhancement centered at or just below a site of spinal canal stenosis, consideration should be given to chest imaging and lymph node biopsy when applicable, to assess for the possibility of underlying sarcoidosis before surgical decompression.

23 August 2025 in Radiology Advances
Verified
Journal Article
Open access
SLShawn K Lyo
Shawn K Lyo
SMSuyash Mohan
Suyash Mohan
MHMichael J Hoch
Michael J Hoch
VPVivek P Patel
Vivek P Patel
RKRobert M Kurtz
Robert M Kurtz
AHAlvand Hassankhani
Alvand Hassankhani
Background: Magnetic resonance imaging (MRI) is a cornerstone of neuroimaging but is limited by lengthy acquisition times, which can lead to motion artifacts, patient discomfort, and delayed care. Deep learning reconstruction is an emerging technology that can offer image acquisition acceleration while maintaining image quality. Purpose: To compare image quality and acquisition efficiency between deep learning–accelerated vs conventional MRI (C-MRI) across a spectrum of routine neuroradiologic examinations. Materials and Methods: In this single-center retrospective study, 26 patients underwent imaging with a commercially available, FDA-cleared deep learning-accelerated MRI reconstruction algorithm (Deep Resolve, Siemens Healthineers), and C-MRI on a Siemens 3 T MAGNETOM Vida scanner between October 24 and November 14, 2023. A total of 113 sequence pairs were acquired across multiple body parts (brain [n = 28], cervical spine [n = 24], thoracic spine [n = 16], lumbar spine [n = 14], internal auditory canals [n = 5], sella [n = 5], neck [n = 5], temporomandibular joints [n = 6], brachial plexus [n = 4], and orbits [n = 6]) and sequences (T2 [n = 38], T1 [n = 30], short tau inversion recovery [n = 21], T1 post-contrast [n = 17], T2 fluid attenuated inversion recovery [n = 5], and proton density [n = 2]) and evaluated by 4 neuroradiologists blinded to the acquisition method for image quality using a 5-point Likert scale. Acquisition parameters were extracted from Digital Imaging and Communications in Medicine (DICOM) metadata and statistically compared. Rater preferences and interrater reliability were assessed using nonparametric tests and intraclass correlation coefficients. Results: Deep learning reduced mean scan time by 51.6% (95% CI: 45.7%–57.7%; from 110.8 seconds to 53.7 seconds; P < .001). Image quality assessments using a Likert scale showed scores slightly above neutral for signal-to-noise ratio (mean 3.51; 95% CI: 3.44–3.58), structural delineation (mean 3.51, 95% CI: 3.44–3.56), and overall image quality (mean 3.56, 95% CI: 3.49–3.63). However, poor interrater reliability (intraclass correlation [ICC] range: 0.06–0.33) showed that the observed differences were not consistent, indicating functional equivalence between conventional and deep learning images. Conclusion: Deep learning MRI enabled substantial scan time reductions while maintaining image quality.

29 April 2021 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
ABAlok A. Bhatt
Alok A. Bhatt
RKR.M. Kurtz
R.M. Kurtz
TKT.A. Kennedy
T.A. Kennedy
MMM.M. Miller-Thomas
M.M. Miller-Thomas
JAJ.C. Anderson
J.C. Anderson
CWC.P. Wood
C.P. Wood
SUMMARY: The Accreditation Council for Graduate Medical Education is currently in the process of specialty-by-specialty revision of the Milestones. As a result, the Neuroradiology Milestones 2.0 Workgroup was created to refine a system of competency-based assessments for fellow educational growth and development. Strengths of the new Milestones include decreased complexity and uniformity within a subcompetency as it relates to a specific educational development trajectory. The Supplemental Guide serves to decrease clutter in the Milestones 2.0 document and provides a more practical resource for guidance. This article serves to review the history of the Neuroradiology Milestones, followed by a summary of the timeline of events and discussions of the workgroup for development of Neuroradiology Milestones 2.0 and a synopsis of major changes. The plan is for the updated Neuroradiology Milestones to take effect in 2021 or 2022 based on public commentary.

7 April 2011
Verified
Book Chapter
Closed access
RKRobert M. Kurtz
Robert M. Kurtz
RWRonnie B. Wilbur
Ronnie B. Wilbur
Two adult raters viewed videotapes of children with and without SLI in spontaneous conversations. Raters identified violations of conversational rules and assigned each to a category based on a system developed by Bishop and Adams (1989). Children with SLI produced significantly more violations than their typical peers. All but two of the violations were analyzed as falling under the Gricean maxims of relation and quantity, consistent with results of earlier studies of younger, typically-developing children. These findings confirm that children with SLI exhibit lower pragmatic competence than their typically developing peers, inviting further study comparing children with SLI with younger controls to investigate the contributions of language development and cognitive maturation.