Channel catfish virus disease (CCVD) has resulted in great economic losses and has restricted the development of fisheries. There is therefore, a need for rapid and efficient diagnostic methods to control the spread of CCVD. A colloidal gold immunochromatographic strip has been developed for the detection of CCVD. In this study, a colloidal gold immunochromatographic strip for channel catfish virus (CCV) detection was developed using the monoclonal antibody 8B6 conjugated with colloidal gold as the detector antibody. A rabbit anti-CCV antibody was used as the capture complex at the test line, and a goat anti-mouse IgG antibody was used as the capture antibody at the control line. The strip was characterized in its specificity, sensitivity, and stability. In addition, an infection experiment was performed to test the applicability of the test strip. The strip was able to detect concentrations of the virus (104 tissue culture infective dose (TCID50)/mL) and showed analytical specificity when tested against other viral pathogens. The strips were still usable after 30 days of storage at 60°C. It was possible to detect CCV experimentally in infected fish within 10–15 min of using the strip. The strip can be used as a rapid and convenient tool for on-site diagnosis to control outbreaks and the spread of CCVD. The immunochromatographic strip was the first to be developed and applied for the detection of CCVD.
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has rapidly spread over the world since its emergence. Although the dominant route of SARS-CoV-2 infection is respiratory, a number of studies revealed infection risk from contaminated surfaces and products, including porcine-derived food and other products. The SARS-CoV-2 outbreak has been severely threatening public health, and disrupting porcine products trade and the pig industry. Swine acute diarrhea syndrome coronavirus (SADS-CoV), which was responsible for large-scale, fatal disease in piglets, emerged in 2017 and has caused enormous economic losses in the pig industry. Currently, reverse transcription real-time PCR (RT-rPCR) is the gold standard method for SARS-CoV-2 diagnosis and is most commonly used for SADS-CoV detection. However, inaccurate detection of the SARS-CoV-2 infection obtained by RT-rPCR is increasingly reported, especially in specimens with low viral load. This study aimed to develop an accurate reverse transcription droplet digital PCR (RT-ddPCR) assay for the detection of SARS-CoV-2 and SADS-CoV simultaneously. Two pairs of primers and one double-quenched probe targeting the RNA-dependent RNA polymerase (RDRP) region of the open reading frame 1ab (ORF1ab) gene of SARS-CoV-2 and the corresponding ORF1ab region of SADS-CoV were designed to develop the RT-ddPCR assay. The sensitivity, specificity, repeatability, and reproducibility were tested using complementary RNAs (cRNAs) and clinical specimens. The detection limits of RT-ddPCR were 1.48 ± 0.18 and 1.38 ± 0.17 copies in a 20 μL reaction for SARS-CoV-2 and SADS-CoV cRNAs, respectively (n = 8), showing approximately 4- and 10-fold greater sensitivity than the RT-rPCR assay. This assay also exhibited good specificity, repeatability, and reproducibility. The established RT-ddPCR assay was shown to be a highly effective, accurate, and reliable method for the sensitive detection of SARS-CoV-2 and SADS-CoV. This RT-ddPCR assay could be used to detect both SARS-CoV-2 and SADS-CoV in a sample with one double-quenched probe, and is also the first reported RT‐ddPCR assay for SADS-CoV detection.
Background: The zinc finger BED-type containing six knockout (ZBED6-KO) pigs were created to improve economic traits by increasing the expression of insulin-like growth factor 2. They were generated by CRISPR/CRISPR-associated protein 9 (Cas9) technology and a single-base deletion of ZBED6 was found. An efficient and rapid method was needed to detect this type of pig. Objective: This study aimed to develop a high-resolution melting (HRM) method to detect ZBED6-KO pigs. Methods: An unlabeled probe and two primers were designed to develop the HRM method. The limit of detection, specificity, and accuracy of the established method were tested by the constructed plasmid and DNA extracts of tissue specimens. Results: The limit of detection by the established method was 102 copies/µL. The HRM method with an unlabeled probe showed good specificity and high accuracy. Conclusions: The established HRM analysis with an unlabeled probe showed it to be a highly effective, rapid, and reliable method to distinguish ZBED6-KO pigs from wild-type pigs. Highlights: It is the first time that HRM analysis with an unlabeled probe has been used in the detection of genome editing pigs by the CRISPR/Cas9 technology.
Background: Bovine coronavirus (BCoV) is an economically significant pathogen that causes respiratory and enteric infections in cattle and wild ruminants. Although multiple diagnostic methods are available, there is still an urgent need for a sensitive real-time reverse transcription quantitative PCR (RT-qPCR) assay capable of detecting continuously emerging novel strains of BCoV. Objective: This study aimed to develop a sensitive and broad-spectrum RT-qPCR assay for the efficient detection of BCoV. Methods: Following optimization and comparison of two primer-probe sets targeting the M gene, an RT-qPCR assay was established. Using Decaro’s method as a reference, gradient dilutions of transcribed RNA solutions and BCoV-derived cDNA were prepared to test sensitivity, repeatability, and reproducibility. Additionally, four other bovine viruses were used to evaluate specificity. Finally, the diagnostic sensitivity and specificity of both assays were analyzed using 46 field samples. Results: A sensitive and broad-spectrum RT-qPCR assay was developed in this study. Its analytical sensitivity was 10 copies/μL with transcribed RNA as the template, comparable to that of Decaro’s method. While the cDNA of an emerging Chinese viral isolate was used as the template, the analytical sensitivity was one order of magnitude higher than that of Decaro’s method. Reproducibility testing revealed intra-assay coefficients of variation (CV) ranging from 1.75 to 3.56%, and inter-assay CV values between 3.13 and 4.91%. When evaluating the diagnostic sensitivity and specificity with 46 field samples, our assay exhibited higher diagnostic sensitivity compared to Decaro’s method, a difference explained by two mutations within the primer and probe regions of Decaro’s method. Conclusion: A highly sensitive and broad-spectrum RT-qPCR assay was successfully developed for the detection of BCoV, especially for the detection of emerging novel strains. Highlights: The RT-qPCR assay developed in this study exhibited high sensitivity, particularly in detecting BCoV field strains and newly emerging variants circulating in recent years.