Trent She

Trent She

Auto-generated profile, based on publicly available information

Trent She

Department of Emergency Medicine Hartford Hospital Hartford Connecticut USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2023 in POCUS Journal
Verified
Journal Article
Open access
PDF file
ZBZachary Boivin
Zachary Boivin
CXCurtis Xu
Curtis Xu
DDDonias Doko
Donias Doko
MHMeghan Kelly Herbst
Meghan Kelly Herbst
TSTrent She
Trent She
Background: The prevalence of phantom scanning, or point of care ultrasound (POCUS) performed without saving images, has not been well studied. Phantom scanning can negatively affect patient care, reduce billed revenue, and can increase medicolegal liability. We sought to quantify and compare the prevalence of phantom scanning among emergency department (ED) cardiac arrests and trauma resuscitations. Methods: This was a single center, retrospective cohort study from July 1, 2019, to July 1, 2021, of all occurrences of POCUS examination documented on the resuscitation run sheet during cardiac arrest and trauma resuscitations. Two investigators reviewed the run sheets to screen for POCUS documentation. Instances where documentation was present were matched with saved images in the picture archiving and communication system. Instances where documentation was present but no images could be located were considered phantom scans. A two-tailed student’s t test was utilized to compare the phantom scanning rate between cardiac arrest and trauma resuscitations. Results: A total of 1,862 patients were included in the study period, with 329 cardiac arrests and 401 trauma resuscitations having run sheet documentation of POCUS performance. The phantom scanning rate in cardiac arrests and trauma resuscitations was 70.5% (232/329) and 86.5% (347/401), respectively (p < 0.001). Conclusion: Phantom scanning is common in both cardiac arrests and trauma resuscitations in the ED at our institution, but is significantly higher in trauma resuscitations. Further research is needed to assess causes and develop potential solutions to reduce the high prevalence of phantom scanning.

22 April 2024 in POCUS Journal
Verified
Journal Article
Open access
PDF file
DCDavid Cannata
David Cannata
CLCallista Love
Callista Love
PCPascale Carrel
Pascale Carrel
TSTrent She
Trent She
SLSeth Lotterman
Seth Lotterman
MHMeghan Herbst
Meghan Herbst
Background: Point of care ultrasound (POCUS) is specific for acute cholecystitis (AC), but surgeons request radiology imaging (RI) prior to admitting patients with POCUS-diagnosed AC. Objectives: We sought to determine the test characteristics of POCUS for AC when performed and billed by credentialed emergency physicians (EPs), the accuracy rate of RI when performed after POCUS, and the time added when RI is requested after POCUS demonstrates AC. Methods: We performed a dual-site retrospective cohort study of admitted adult ED patients who had received biliary POCUS from November 1, 2020 to April 30, 2022. Patients with previously diagnosed AC, liver failure, ascites, hepatobiliary cancer, or cholecystectomy were excluded. Descriptive statistics and 95% confidence intervals for point estimates were calculated. Medians were compared using a Wilcoxon signed-rank test. Test characteristics of POCUS for AC were calculated using inpatient intervention for AC as the reference standard. Results: Of 473 screened patients, 143 were included for analysis: 80 (56%) had AC according to our reference standard. POCUS was positive for AC in 46 patients: 44 true positives and two false positives, yielding a positive likelihood ratio of 17.3 (95%CI 4.4-69.0) for AC. The accuracy rate of RI after positive POCUS for AC was 39.0%. Median time from ED arrival to POCUS and ED arrival to RI were 115 (IQR 64, 207) and 313.5 (IQR 224, 541) minutes, respectively; p < 0.01. Conclusion: RI after positive POCUS performed by credentialed EPs takes additional time and may increase diagnostic uncertainty.

1 October 2013 in Annals of Emergency Medicine
Verified
Journal Article
Open access
BLB.L. Lopez
B.L. Lopez
POP. Owens
P. Owens
TST. She
T. She

15 April 2025 in POCUS Journal
Verified
Journal Article
Open access
PDF file
EGEmily Gohde
Emily Gohde
SLSeth Lotterman
Seth Lotterman
IIIkram Irfanullah
Ikram Irfanullah
DHDavid Hansen
David Hansen
FPFelix Pacheco
Felix Pacheco
TSTrent She
Trent She
Emergent transvenous pacing can be performed for patients with an unstable bradyarrhythmia in the emergency department. While emergent transvenous pacemaker (TVP) placement is performed relatively rarely, its importance in the management of these patients requires emergency physicians to be familiar with the procedure. Point of care ultrasound (POCUS) is traditionally used for the initial vascular access associated with TVP placement but can also be indispensable in the subsequent placement and advancement of the TVP wire itself. This article discusses two cases and then outlines a general protocol that incorporates POCUS into a standard emergent TVP procedure. Further, we outline some common POCUS troubleshooting tactics to improve success and ways in which POCUS can rapidly identify complications.

28 January 2025 in Visual Journal of Emergency Medicine
Verified
Journal Article
Closed access
LMLindsay Mello
Lindsay Mello
JTJoseph Testa
Joseph Testa
TSTrent She
Trent She

7 September 2026 in AEM Education and Training
Verified
Journal Article
Closed access
PDF file
LDLachlan Driver
Lachlan Driver
LPLeland Perice
Leland Perice
TSTrent She
Trent She
JPJoseph R. Pare
Joseph R. Pare