Nami Saito

Nami Saito

Auto-generated profile, based on publicly available information

Nami Saito

GSI Helmholtzzentrum für Schwerionenforschung GmbH, Abteilung Biophysik, Planckstraße 1, 64291 Darmstadt, Germany

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2009 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
NSNami Saito
Nami Saito
CBChristoph Bert
Christoph Bert
NCNaved Chaudhri
Naved Chaudhri
AGAlexander Gemmel
Alexander Gemmel
DSDieter Schardt
Dieter Schardt
EREike Rietzel
Eike Rietzel
The technical performance of an integrated three-dimensional carbon ion pencil beam tracking system that was developed at GSI was investigated in phantom studies. Aim of the beam tracking system is to accurately treat tumours that are subject to respiratory motion with scanned ion beams. The current system provides real-time control of ion pencil beams to track a moving target laterally using the scanning magnets and longitudinally with a dedicated range shifter. The system response time was deduced to be approximately 1 ms for lateral beam tracking. The range shifter response time has been measured for various range shift amounts. A value of 16 +/- 2 ms was achieved for a water equivalent shift of 5 mm. An additional communication delay of 11 +/- 2 ms was taken into account in the beam tracking process via motion prediction. Accuracy of the lateral beam tracking was measured with a multi-wire position detector to < or =0.16 mm standard deviation. Longitudinal beam tracking accuracy was parameterized based on measured responses of the range shifter and required time durations to maintain a specific particle range. For example, 5 mm water equivalence (WE) longitudinal beam tracking results in accuracy of 1.08 and 0.48 mm WE in root mean square for time windows of 10 and 50 ms, respectively.

30 June 2010 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
CBChristoph Bert
Christoph Bert
AGAlexander Gemmel
Alexander Gemmel
NSNami Saito
Nami Saito
NCNaved Chaudhri
Naved Chaudhri
DSDieter Schardt
Dieter Schardt
EREike Rietzel
Eike Rietzel
Scanned ion beam therapy of intra-fractionally moving tumors requires motion mitigation. GSI proposed beam tracking and performed several experimental studies to analyse the dosimetric precision of the system for scanned carbon beams.

1 January 2009 in IFMBE Proceedings
Verified
Book Chapter
Closed access
PDF file
NSNami Saito
Nami Saito
CBChristoph Bert
Christoph Bert
NCNaved Chaudhri
Naved Chaudhri
AGAlexander Gemmel
Alexander Gemmel
DSDieter Schardt
Dieter Schardt
EREike Rietze
Eike Rietze