Ed. G. Marins

Ed. G. Marins

Auto-generated profile, based on publicly available information

Ed. G. Marins

Roche Molecular Systems, Inc., Pleasanton, United States

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Journal of Clinical Virology
Verified
Journal Article
Open access
JYJoseph D. Yao
Joseph D. Yao
SYStephen Young
Stephen Young
GHGabrielle M. Heilek
Gabrielle M. Heilek
EMEnrique Marino
Enrique Marino
EPEllen E. Paxinos
Ellen E. Paxinos
AVAlexandra Valsamakis
Alexandra Valsamakis
Accurate, sensitive, and specific tests for detection and monitoring of hepatitis C virus (HCV) RNA concentrations are essential for diagnosis and management of HCV infections. We evaluated the next-generation reverse-transcription real-time PCR test, cobas® HCV test for use with the cobas® 6800/8800 systems ("cobas HCV") by determining its analytical performance characteristics and clinical utility for the diagnosis and therapeutic monitoring of chronic HCV infections. The limit of detection (LOD), linearity, precision, specificity, matrix equivalence of plasma and serum, and quantitative agreement with the COBAS® AmpliPrep/COBAS® TaqMan® HCV Test version 2.0 ("CAP/CTM HCV v2") were evaluated. Clinical utility for the diagnosis of chronic HCV infection was demonstrated by testing plasma from HCV seropositive individuals and comparing results to a nucleic acid amplification test (NAAT) approved for use in the diagnosis of chronic hepatitis C. Clinical specificity was investigated by testing plasma from HCV antibody negative subjects with non-HCV related liver diseases. Utility for monitoring treatment response was defined by testing plasma collected during treatment of HCV genotypes (GT) 1, 2, and 3 and determining positive predictive value (PPV), negative predictive value (NPV) and the odds ratio (OR) for predicting cure (sustained virologic response 12 weeks after treatment cessation, "SVR12"). The cobas HCV test demonstrated an LOD of at least 15 IU/mL and measurable range from 15 to at least 1.0E + 08 IU/mL (1.2-8.0 log10 IU/mL) for GT 1-6, with high accuracy (≤0.16 log10 difference) and precision (standard deviation 0.04-0.14 log10) throughout the linear range. Paired plasma and serum samples showed highly correlated performance (R2 = 0.97). Quantification was 100% specific for HCV in analytical studies. Correlation with CAP/CTM HCV v2 was high in patient samples (mean titer difference: 0.05 log10 with a 95% CI: 0.03-0.06 log10). For the diagnosis of chronic HCV, positive and negative percent agreement between cobas HCV and the comparator NAAT were 98.8-100% on the cobas 6800 and 8800 systems. Clinical specificity of cobas HCV using samples from HCV antibody negative subjects with non-HCV related liver diseases was 99.6% and 100% on cobas 6800 and 8800 systems. In therapeutic monitoring and SVR12 prediction during experimental treatment for chronic HCV GT 1 infections, undetectable HCV RNA by cobas HCV at different on-treatment weeks had a PPV 76.8%-79.4%, NPV 29.9%-100%, and OR 1.64-47.52. During therapy of HCV GT 2 and GT 3, treatment week 4 and 12 results were: PPV, 84.7% and 75.3%; NPV, 47.8% and 50.0%; OR, 5.09 and 3.05. The cobas HCV test is highly sensitive, specific, and accurate HCV RNA test for GT 1-6. It demonstrates excellent correlation with the FDA-approved CAP/CTM HCV v2 test. It is useful clinically for detection of active HCV infection in individuals that have had a positive anti-HCV antibody test result and in monitoring treatment response.

1 April 2017 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
PDF file
JVJohannes Vermehren
Johannes Vermehren
ESEvelyn Stelzl
Evelyn Stelzl
BMBenjamin Maasoumy
Benjamin Maasoumy
VMVeronique Michel-Treil
Veronique Michel-Treil
CBCaterina Berkowski
Caterina Berkowski
HKHarald H. Kessler
Harald H. Kessler
The efficacy of antiviral treatment for chronic hepatitis C virus (HCV) infection is determined by measuring HCV RNA at specific time points throughout therapy using highly sensitive and accurate HCV RNA assays. This study compared the performances of two recently developed real-time PCR HCV RNA assays, cobas HCV for use on the cobas 6800/8800 systems (cobas 6800/8800 HCV) and cobas HCV for use on the cobas 4800 system (cobas 4800 HCV), with those of two established assays, the Cobas AmpliPrep/Cobas TaqMan HCV quantitative test, version 2 (CAP/CTM v2) and the Cobas TaqMan HCV test, version 2 for use with the High Pure system (HPS/CTM v2). The limits of detection (LODs) and linearity at lower concentrations (5 to 1000 IU/ml) were assessed for cobas 6800/8800 HCV and cobas 4800 HCV using WHO standard traceable panels representing HCV genotypes (GT) 1 to 4. Pairwise assay comparisons were also performed using 245 clinical samples representing HCV GT 1 to GT 4. Results from cobas 6800/8800 HCV and cobas 4800 HCV were linear at low HCV RNA concentrations (<0.3 log10 IU/ml difference between expected and observed results) with LODs of 8.2 IU/ml and 11.7 IU/ml, respectively, for GT 1. The new assays showed excellent agreement with results from CAP/CTM v2 and HPS/CTM v2 in samples with quantifiable viral loads. The concordances using the 6 million IU/ml cutoff were high among all four assays (90 to 94%). In conclusion, the cobas 6800/8800 HCV and cobas 4800 HCV tests are sensitive and linear and correlate well with the established Roche assays used in clinical practice.

7 August 2017 in Therapeutic Advances in Gastroenterology
Verified
Journal Article
Open access
BMBenjamin Maasoumy
Benjamin Maasoumy
BBBirgit Bremer
Birgit Bremer
PLPatrick Lehmann
Patrick Lehmann
EMEd G. Marins
Ed G. Marins
VMVéronique Michel-Treil
Véronique Michel-Treil
HWHeiner Wedemeyer
Heiner Wedemeyer
Background: HBV DNA is the most important molecular marker in hepatitis B, used to determine treatment indication and monitoring. Most patients require lifelong hepatitis B virus (HBV) management, thus viral load (VL) monitoring may be performed at different laboratories, with different HBV assays, which may result in different VL results. This multicenter study compares the commutability and concordance of results from four different HBV DNA assays: CAP/CTM HBVv2, HPS/CTM HBVv2 and the new cobas 6800/8800 HBV and cobas 4800 HBV assays. Methods: Across all four assays, HBV limit of detection (LoD) and linearity at lower concentrations were assessed using panels traceable to the World Health Organization international standard, and concordance was investigated at the important medical decision cutoffs 2000 and 20,000 IU/ml, using specimens from HBV-positive patients. Results: The calculated LoD via a probit curve was 2.7 IU/ml for cobas 6800/8800 HBV, 2.8 IU/ml for cobas 4800 HBV, 9.6 IU/ml for CAP/CTM HBVv2, and 6.2 IU/ml for HPS/CTM HBVv2. The average accuracy was comparable between cobas 6800/8800 HBV, cobas 4800 HBV and CAP/CTM HBVv2 (0.04–0.05 log10 IU/ml), while a slightly lower accuracy was documented for HPS/CTM HBVv2 (−0.16 log10 IU/ml). A total of 211–245 clinical samples were used for a pairwise comparison. Mean paired log differences ranged from −0.17 log10 IU/ml to −0.01 log10 IU/ml. Coefficient of determination was over 98% for all pairs with high overall percent agreement at the 2000 and 20,000 IU/ml cutoffs (from 91.7% to 96.3%). In a subset of samples with VL±0.5 log10 to the 2000 and 20,000 IU/ml thresholds, concordance was still 72% and 82%, respectively. Conclusions: The new cobas 6800/8800 HBV and 4800 HBV assays show high accuracy in samples with low-level viremia and a high concordance with the established HBV tests, CAP/CTM HBVv2 and HPS/CTM HBVv2, at 2000 and 20,000 IU/ml. Thus, all four HBV assays have high commutability and may be used interchangeably in routine clinical practice.

25 July 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ESEvelyn Stelzl
Evelyn Stelzl
BHBernhard Haas
Bernhard Haas
BBBernd Bauer
Bernd Bauer
SZSherry Zhang
Sherry Zhang
EFEllen H. Fiss
Ellen H. Fiss
HKHarald H. Kessler
Harald H. Kessler
Hepatitis C virus (HCV) intergenotypic recombinant forms have been reported for various HCV genotypes/subtypes in several countries worldwide. In a recent study, four patients living in Austria had been identified to be possibly infected with a recombinant HCV strain. To clarify results and determine the point of recombination, full-genome next-generation sequencing using the Illumina MiSeq v2 300 cycle kit (Illumina, San Diego, CA, USA) was performed in the present study. Samples of all of the patients contained the recombinant HCV strain 2k/1b. The point of recombination was found to be within the HCV NS2 gene between nucleotide positions 3189–3200 based on H77 numbering. While three of four patients were male and had migration background from Chechnya (n = 2) and Azerbaijan (n = 1), the forth patient was a female born in Austria. Three of the four patients including the female had intravenous drug abuse as a risk factor for HCV transmission. While sequencing techniques are limited to a few specialized laboratories, a genotyping assay that uses both ends of the HCV genome should be employed to identify patients infected with a recombinant HCV strain. The correct identification of recombinant strains also has an impact considering the tailored choice of anti-HCV treatment.

1 January 2017 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Open access
PDF file
ESEvelyn Stelzl
Evelyn Stelzl
HAHannah M. Appel
Hannah M. Appel
RMRochak Mehta
Rochak Mehta
EMEd G. Marins
Ed G. Marins
JBJörg Berg
Jörg Berg
HKHarald H. Kessler
Harald H. Kessler
Determination of the hepatitis C virus (HCV) genotype and discrimination between HCV subtypes 1a and 1b is still mandatory prior to anti-HCV treatment initiation. The aim of this study was to evaluate the performance of the recently introduced cobas® HCV GT assay (Roche) and to compare it to two comparator assays. The cobas® HCV GT assay is based on primer-specific real-time polymerase chain reaction (PCR). For comparison, the TRUGENE® HCV 5'NC Genotyping Kit (Siemens) and the VERSANT® HCV Genotype 2.0 Assay (Siemens) were employed. Accuracy of the new assay was determined using proficiency panels. For clinical evaluation, 183 residual clinical samples obtained from patients with chronic hepatitis C infection were included. When accuracy was tested, panel members containing HCV subtypes 1a, 1b, and 3a were identified as expected; however, the new assay failed to identify low titer panel members containing HCV subtype 5a correctly. Of 183 clinical samples, 160 gave concordant results. For seven samples, an indeterminate result was reported with the cobas® HCV GT assay and the remaining 16 samples were found discordant with one of the comparator assays. When time-to-results of the assays were compared, the new assay showed shorter total time and similar hands-on time per sample. The cobas® HCV GT assay showed a good performance and proved to be suitable for use in the routine diagnostic laboratory. Due to the high level of automation, fast and reliable results are obtained with short hands-on time.

1 May 2019 in Journal of Clinical Virology
Verified
Journal Article
Closed access
PAPhillip Adams
Phillip Adams
EVEllen Vancutsem
Ellen Vancutsem
CNCyrielle Nicolaizeau
Cyrielle Nicolaizeau
JSJean-Yves Servais
Jean-Yves Servais
DPDenis Pierard
Denis Pierard
CSCarole Seguin-Devaux
Carole Seguin-Devaux