Tetsuya Mori

Tetsuya Mori

Auto-generated profile, based on publicly available information

Tetsuya Mori

Biomedical Imaging Research Center, University of Fukui, Fukui 910-1193, Japan

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2005 in Journal of Dermatological Science
Verified
Journal Article
Open access
KNKeisuke Nagao
Keisuke Nagao
TOTakayuki Ota
Takayuki Ota
ATAkiko Tanikawa
Akiko Tanikawa
YTYujiro Takae
Yujiro Takae
TMTetsuya Mori
Tetsuya Mori
TNTakeji Nishikawa
Takeji Nishikawa
Mucormycosis is an invasive opportunistic infection caused by fungi belonging to the order Mucorales. Due to the lack of laboratory tests, the diagnosis of mucormycosis is notoriously difficult. Added with its rapid progression as well as the debilitated state of the patients who contract the disease, mortality is extremely high. The goal of this study was to genetically identify human pathogenic Rhizopus species, a major mucormycosis agent, by the internal transcribed spacer (ITS) region of rRNA gene. Primers were designed to identify five Rhizopus species known to cause human disease by multiplex PCR. PCR was done not only with test strains and clinical isolates, but also with clinical samples from cutaneous mucormycosis patients. Sporangiospore morphology was observed by scanning electron microscopy to confirm the correlation of phenotypic and genotypic features. Multiplex PCR identified five Rhizopus species including Rhizopus oryzae, where R. azygosporus could only be distinguished from R. microsporus by certain polymorphisms that were present in its sequence. When this multiplex PCR was applied to clinical samples from three mucormycosis patients (paraffin sections from all and sera from one patient), Rhizopus DNA corresponding to the isolated pathogens were specifically detected. While fungal DNA detection from clinical samples is a rigorously studied area, this is the first report to genetically identify and detect Rhizopus species from human mucormycosis specimens. This may expand the possibility of this multiplex PCR system not only to identify isolated fungi, but also as a screening method for visceral mucormycosis.

22 May 2022 in Antioxidants
Verified
Journal Article
Open access
PDF file
Hidehiko OkazawaHidehiko Okazawa
Hidehiko Okazawa
MIMasamichi Ikawa
Masamichi Ikawa
TTTetsuya Tsujikawa
Tetsuya Tsujikawa
TMTetsuya Mori
Tetsuya Mori
AMAkira Makino
Akira Makino
MYMakoto Yoneda
Makoto Yoneda
Oxidative stress imaging using diacetyl-bis (N4-methylthiosemicarbazone) (Cu-ATSM) was applied to the evaluation of patients with early Alzheimer’s disease (eAD). Ten eAD patients (72 ± 9 years) and 10 age-matched healthy controls (HCs) (73 ± 9 years) participated in this study. They underwent dynamic PET/MRI using 11C-PiB and 64Cu-ATSM with multiple MRI sequences. To evaluate cerebral oxidative stress, three parameters of 64Cu-ATSM PET were compared: standardized uptake value (SUV), tracer influx rate (Kin), and a rate constant k3. The input functions were estimated by the image-derived input function method. The relative differences were analyzed by statistical parametric mapping (SPM) using SUV and Kin images. All eAD patients had positive and HC subjects had negative PiB accumulation, and MMSE scores were significantly different between them. The 64Cu-ATSM accumulation tended to be higher in eAD than in HCs for both SUV and Kin. When comparing absolute values, eAD patients had a greater Kin in the posterior cingulate cortex and a greater k3 in the hippocampus compared with lobar cortical values of HCs. In SPM analysis, eAD had an increased left operculum and decreased bilateral hippocampus and anterior cingulate cortex compared to HCs. 64Cu-ATSM PET/MRI and tracer kinetic analysis elucidated cerebral oxidative stress in the eAD patients, particularly in the cingulate cortex and hippocampus.

19 March 2019 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
Hidehiko OkazawaHidehiko Okazawa
Hidehiko Okazawa
TTTetsuya Tsujikawa
Tetsuya Tsujikawa
YHYoshifumi Higashino
Yoshifumi Higashino
KKKen-Ichiro Kikuta
Ken-Ichiro Kikuta
TMTetsuya Mori
Tetsuya Mori
YKYasushi Kiyono
Yasushi Kiyono
Accurate attenuation correction (AC) is one of the most important issues to be addressed in quantitative brain PET/MRI imaging. Atlas-based MRI AC (AB-MRAC), one of the representative MRAC methods, has been used to estimate the skull attenuation in brain scans. The zero echo time (ZTE) pulse sequence is also expected to provide a better MRAC estimation in brain PET scans. The difference in quantitative measurements of cerebral blood flow (CBF) using H215O-PET/MRI was compared between the two MRAC methods, AB and ZTE. Twelve patients with cerebrovascular disease (4 males, 43.2 ± 11.7 years) underwent H215O-PET/MRI studies with a 3-min PET scan and MRI scans including the ZTE sequence. Eleven of them were also studied under the conditions of baseline and 10 min after acetazolamide administration, and 2 of them were followed up after several months interval. A total of 25 PET images were reconstructed as dynamic data using 2 sets of reconstruction parameters to obtain the image-derived input function (IDIF), the time-activity curves of the major cerebral artery extracted from images, and CBF images. The CBF images from AB- and ZTE-MRAC were then compared for global and regional differences. The mean differences of IDIF curves at each point obtained from AB- and ZTE-MRAC dynamic data were less than 5%, and the differences in time-activity curves were very small. The means of CBF from AB- and ZTE-MRAC reconstructions calculated using each IDIF showed differences of less than 5% for all cortical regions. CBF images from AB-MRAC tended to show greater values in the parietal region and smaller values in the skull base region. The CBF images from AB- and ZTE-MRAC reconstruction showed no significant differences in regional values, although the parietal region tended to show greater values in AB-MRAC reconstruction. Quantitative values in the skull base region were very close, and almost the same IDIFs were obtained.

15 February 2019 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
TTTetsuya Tsujikawa
Tetsuya Tsujikawa
TTToshiki Tasaki
Toshiki Tasaki
NHNaoko Hosono
Naoko Hosono
TMTetsuya Mori
Tetsuya Mori
AMAkira Makino
Akira Makino
Hidehiko OkazawaHidehiko Okazawa
Hidehiko Okazawa
Bone marrow failure syndrome (BMFS) is a heterogeneous group of disorders associated with single- or multiple-lineage cytopenia and failure of normal hematopoiesis. We assessed the feasibility of integrated PET/MRI with 3′-deoxy-3′-18F-fluorothymidine (18F-FLT) to assess the pathophysiology of whole-body bone marrow for the diagnosis and monitoring of BMFS. Twenty-five consecutive patients with BMFS underwent a pre-treatment 18F-FLT PET/MRI scan. They included 7 patients with aplastic anemia (AA), 16 with myelodysplastic syndrome (MDS), and 2 with myeloproliferative neoplasms (MPNs), primary myelofibrosis (MF), and secondary [post-essential thrombocythemia (post-ET)] MF. Two of the seven AA patients underwent a post-treatment scan. Eight of the 16 MDS patients who exhibited decreased 18F-FLT uptake in the pelvis were considered to have hypoplastic MDS (hypo-MDS). 18F-FLT PET and diffusion-weighted imaging (DWI) were visually and quantitatively evaluated. The 18F-FLT uptake in the ilium was strongly correlated with bone marrow cellularity based on biopsy samples (ρ = 0.85). AA patients exhibited heterogeneously decreased uptake of 18F-FLT according to disease severity. Multiple 18F-FLT foci were observed in the proximal extremities, and they were in the central skeleton in severe AA patients. Post-treatment 18F-FLT PET scans of severe AA patients reflected the response of hematopoietic activity to treatment. MDS patients had marked 18F-FLT uptake in the central skeleton and proximal extremities, whereas hypo-MDS patients had heterogeneously decreased uptake, similar to that of non-severe AA patients. 18F-FLT PET and DWI were unable to predict the progression to leukemia for both MDS and hypo-MDS patients. A primary MF patient had slightly decreased 18F-FLT uptake in the central skeleton, but marked expansion of bone marrow activity to the distal extremities and high uptake of tracer in the extremely enlarged spleen (extramedullary hematopoiesis). In contrast, a secondary (post-ET) MF patient demonstrated marked bone marrow uptake, reflecting the hypercellular marrow with fibrosis. DWI revealed diffusely high signal intensities in both the primary and secondary MF patients. 18F-FLT PET can be used to noninvasively assess whole-body bone marrow proliferative activity and DWI may reflect the different aspects of bone marrow pathophysiology from 18F-FLT PET. 18F-FLT PET/MRI is useful for the diagnosis and monitoring of BMFS, except for the differentiation between non-severe AA and hypo-MDS, and the prediction of progression to leukemia.

12 June 2008 in Molecular Imaging and Biology
Verified
Journal Article
Closed access
PDF file
TLTalakad Goolaiah Lohith
Talakad Goolaiah Lohith
TFTakako Furukawa
Takako Furukawa
TMTetsuya Mori
Tetsuya Mori
Masato KobayashiMasato Kobayashi
Masato Kobayashi
YFYasuhisa Fujibayashi
Yasuhisa Fujibayashi

10 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
YNYudai Nishikawa
Yudai Nishikawa
NTNaoki Takahashi
Naoki Takahashi
SNSho Nishikawa
Sho Nishikawa
YSYuki Shimamoto
Yuki Shimamoto
KNKazuhisa Nishimori
Kazuhisa Nishimori
MIMasayuki Iwano
Masayuki Iwano
This study aimed to evaluate the renal blood flow (RBF) in patients with chronic kidney disease (CKD) using 64Cu(II)-diacetyl-bis(4-methylthiosemicarbazonate) (64Cu-ATSM) for positron emission tomography (PET)/magnetic resonance imaging (MRI). We included five healthy controls (HCs) and ten patients with CKD. The estimated glomerular filtration rate (eGFR) was calculated from the serum creatinine (cr) and cystatin C (cys) levels. The estimated RBF (eRBF) was calculated using the eGFR, hematocrit, and filtration fraction. A single dose of 64Cu-ATSM (300–400 MBq) was administered for RBF evaluation, and a 40 min dynamic PET scan was performed with simultaneous arterial spin labeling (ASL) imaging. PET-RBF images were obtained from the dynamic PET images at 3 min after injection using the image-derived input function method. The mean eRBF values calculated from various eGFR values differed significantly between the patients and HCs; both groups also differed significantly in terms of the RBF values (mL/min/100 g) measured using PET (151 ± 20 vs. 124 ± 22, p < 0.05) and ASL-MRI (172 ± 38 vs. 125 ± 30, p < 0.001). The ASL-MRI-RBF was positively correlated with the eRBFcr-cys (r = 0.858, p < 0.001). The PET-RBF was positively correlated with the eRBFcr-cys (r = 0.893, p < 0.001). The ASL-RBF was positively correlated with the PET-RBF (r = 0.849, p < 0.001). 64Cu-ATSM PET/MRI demonstrated the reliability of PET-RBF and ASL-RBF by comparing them with eRBF. This is the first study to demonstrate that 64Cu-ATSM-PET is useful for assessing the RBF and is well correlated with ASL-MRI.