Orlando Carlos Belmonte Wender

Orlando Carlos Belmonte Wender

Auto-generated profile, based on publicly available information

Orlando Carlos Belmonte Wender

Hospital de Clínicas de Porto Alegre, Brazil

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2020 in Journal of Cardiac Surgery
Verified
Journal Article
Closed access
PDF file
ATAna Paula Tagliari
Ana Paula Tagliari
GSGabriela Vieira Steckert
Gabriela Vieira Steckert
LSLucas Molinari Veloso Silveira
Lucas Molinari Veloso Silveira
AKAdriano Nunes Kochi
Adriano Nunes Kochi
OWOrlando Carlos Belmonte Wender
Orlando Carlos Belmonte Wender

1 January 2011 in Brazilian Journal of Cardiovascular Surgery
Verified
Journal Article
Open access
AAAdriana Silveira de Almeida
Adriana Silveira de Almeida
PPPaulo Dornelles Picon
Paulo Dornelles Picon
OWOrlando Carlos Belmonte Wender
Orlando Carlos Belmonte Wender
This paper evaluates outcomes in patients subjected to surgery for replacement of the aortic valve using biological or mechanical substitutes, where selection of the type of prosthesis is relevant. Three hundred and one patients, randomly selected, who had been subjected to aortic valve replacement surgery between 1990 and 2005, with a maximum follow-up period of 20 years. Survival at 5, 10 and 15 years after surgery using mechanical substitute was 83.9%, 75.4% and 60.2% and, for biological substitute, was 89.3%, 70.4% and 58.4%, respectively (P = 0.939). Factors associated with death were: age, obesity, pulmonary disease, arrhythmia, bleeding and aortic valve failure. Probability free of reoperation for these patients at 5, 10 and 15 years after surgery using mechanical substitute was 97.9%, 95.8% and 95.8% and, for those using bioprostheses, was 94.6%, 91.0% and 83.3%, respectively (P = 0.057). Factors associated with reoperation were: renal failure, prosthesis endocarditis and age. Probability free of bleeding events at 5, 10 and 15 years after surgery using mechanical substitute was 94.5%, 91.7% and 91.7% and, for bioprostheses, was 98.6%, 97.8% and 97.8%, respectively (P = 0.047). Factors associated with bleeding events were: renal failure and mechanical prostheses. The authors have concluded that: 1) mortality was statistically similar in the groups; 2) patient characteristics at baseline were a major determinant of late mortality after surgery; 3) there was a tendency toward reoperation in the bioprostheses group; 4) patients using mechanical prosthesis had more bleeding events as time passed; 5) data presented in this paper is in accordance with current literature.

1 January 2021 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
MGMarcelo Curcio Gib
Marcelo Curcio Gib
TZThamyres Zanirati
Thamyres Zanirati
PSPauline Simas
Pauline Simas
OWOrlando Carlos Belmonte Wender
Orlando Carlos Belmonte Wender
LCLeandro Totti Cavazzola
Leandro Totti Cavazzola
To compare the blood flow in the internal thoracic artery when dissected endoscopically in a conventional manner, in addition to develop a reliable experimental training model for the surgical team. Paired experimental study. Ten pigs were operated and had both internal thoracic arteries dissected, the right with a conventional technique and the left by video endoscopy. The main outcomes to be studied were flow, length, and time of dissection of each vessel. Blood flow measurements were performed with mean heart rate of 100 ± 16 bpm and mean arterial pressure of 89.7 ± 13 mm Hg. The mean blood flow of endoscopic dissection of the internal thoracic artery was 170.2 ± 66.3 mL/min and by direct view was 180.8 ± 70.5 (p = 0.26). Thus, there was no statistically significant difference between the flows, showing no inferiority between the methods. The minimally invasive dissection of the internal thoracic artery was shown to be not inferior to the dissection by open technique in relation to the blood flow in the present experimental model. In addition, the model that we replicated was shown to be adequate for the development of the learning curve and improvement of the endoscopic abilities.