12 April 2022 in IEEE Transactions on Medical Robotics and Bionics
This study aims to develop a robust myoelectric control method for gait phase recognition in a lower-limb exoskeleton robot. In the proposed method, a metric learning-based temporal convolution network (ML-TCN) was utilized to extract discriminative features of the surface electromyography (sEMG) signals and recognize four gait phases: heel strike (HS), foot flat (FF), heel off (HO), and swing (SW). Vicon validated the effectiveness of the sEMG data-acquisition system. The proposed method acquires significantly more discriminative features than long short-term memory (LSTM) or common temporal convolutional network (TCN). The experimental results show that the proposed model has a higher prediction accuracy and stronger robustness against disturbances in complex terrain. Finally, under the complex terrain of level ground-ramp ascending-ramp descending walking, the proposed model’s accuracy of gait phase recognition is 96.22%, which is better than LSTM’s 91.20%. Noise disturbances of 10%, 20%, 30%, 40%, and 50% were added to the test set. Compared with LSTM, the resistance to disturbances of the proposed method increased by 8.15%, 8.79%, 9.67%, 10.6%, and 10.61%, respectively.
4 July 2022 in IEEE Transactions on Automation Science and Engineering
Multisource biosignals are being increasingly used in human–machine interaction applications. In particular, a critical problem in exoskeleton-assisted rehabilitation for patients with hemiplegia is the generation of rhythmic and symmetrical locomotion. To support lower limb rehabilitation, we propose a model for predicting contralateral joint angles using multisource biosignals. First, a vibroarthrography (VAG) sensor is attached to the affected leg, and surface electromyography sensors are attached to the sound leg. The corresponding signals are used to estimate the hip, knee, and ankle joint angles of the affected leg. Second, an algorithm based on a temporal convolution network (TCN) is introduced to predict the contralateral lower-limb joint angles during human locomotion. The TCN is compared with a long short-term memory (LSTM) network and a convolutional neural network. Experiments were conducted by 10 healthy participants. The results of the proposed model were compared with measurements from encoders in three joints mounted on an exoskeleton to verify the applicability of the proposed model. In addition, by using the outputs of a motion capture system as the ground truth, the experimental results validated the model prediction performance. The prediction root mean square error (RMSE) of the TCN was 52%–70% lower than that of the LSTM network and CNN at different paces. The prediction RMSE using VAG was 20%–24% lower than that without using VAG. Note to Practitioners—We propose a model for predicting the contralateral lower-limb joint angles of an exoskeleton. The model uses measurements from multiple biosignal sensors to support exoskeleton-assisted hemiplegia rehabilitation. A sensing system based on acoustic signals and bioelectric signals is developed to improve the joint angle prediction in the affected leg of patients with hemiplegia. A temporal convolution network is implemented to estimate joint angles, and training considering the root mean square error and Pearson correlation coefficient as evaluation indicators is performed. Unlike similar methods that include no sensory feedback from the affected leg, the proposed method incorporates VAG signals from the affected leg and sEMG signals from the sound leg to handle different degrees of hemiplegia and support the generation of rhythmic and symmetrical locomotion for gait rehabilitation using an exoskeleton.
23 June 2022 in IEEE Robotics and Automation Letters
Lower-limb exoskeleton robots can support hemiplegic patients’ affected limbs and assist in their rehabilitation. In order to set effective control strategies, it is necessary to obtain the user’s motion intention accurately and timeously. These requirements pose many challenges. The surface electromyography (sEMG) signal has long been used for detecting a person’s locomotion mode. However, most traditional myoelectric motion recognition methods need to collect multi-channel sEMG signals (more than eight) and use feature engineering to obtain the desired accuracy. Additionally, traditional methods make decisions when the recognition probability is still uncertain, resulting in misclassification during continuous recognition. In order to overcome these limitations, a dual-purpose autoencoder-guided temporal convolution network (DA-TCN) is proposed, which is used as a motion detection model for a lower-limb exoskeleton robot based on sEMG. In the proposed method, we first obtain four-channel sEMG signals without any feature engineering. Next, the DA-TCN is used to obtain the discriminative deep features of the sEMG signals. Compared with separable features from common TCNs, discriminative features assist in obtaining a more discriminative twins-loss. Finally, the classification result is redetermined by the decoder, based on the reconstruction of deep features, and misclassifications are rejected based on the value of the twins-loss. The performance of the proposed method was evaluated by obtaining data from seven volunteer subjects in seven locomotion modes. The proposed method was able to effectively detect misclassifications and significantly improved the stability of continuous recognition.