2 May 2023 in Physics in Medicine & Biology
Objective. To compare a not adapted (NA) robust planning strategy with three fully automated online adaptive proton therapy (OAPT) workflows based on the same optimization method: dose mimicking (DM). The added clinical value and limitations of the OAPT methods are investigated for head and neck cancer (HNC) patients. Approach. The three OAPT strategies aimed at compensating for inter-fractional anatomical changes by mimiking different dose distributions on corrected cone beam CT images (corrCBCTs). Order by complexity, the OAPTs were: (1) online adaptive dose restoration (OADR) where the approved clinical dose on the planning-CT (pCT) was mimicked, (2) online adaptation using DM of the deformed clinical dose from the pCT to corrCBCTs (OADEF), and (3) online adaptation applying DM to a predicted dose on corrCBCTs (OAML). Adaptation was only applied in fractions where the target coverage criteria were not met (D98% < 95% of the prescribed dose). For 10 HNC patients, the accumulated dose distributions over the 35 fractions were calculated for NA, OADR, OADEF, and OAML. Main results. Higher target coverage was observed for all OAPT strategies compared to no adaptation. OADEF and OAML outperformed both NA and OADR and were comparable in terms of target coverage to initial clinical plans. However, only OAML provided comparable NTCP values to those from the clinical dose without statistically significant differences. When the NA initial plan was evaluated on corrCBCTs, 51% of fractions needed adaptation. The adaptation rate decreased significantly to 25% when the last adapted plan with OADR was selected for delivery, to 16% with OADEF, and to 21% with OAML. The reduction was even greater when the best plan among previously generated adapted plans (instead of the last one) was selected. Significance . The implemented OAPT strategies provided superior target coverage compared to no adaptation, higher OAR sparing, and fewer required adaptations.
29 October 2024 in Acta Oncologica
Background and purpose: Intensity Modulated Proton Therapy (IMPT) faces challenges in lung cancer treatment, like maintaining plan robustness for moving tumors against setup, range errors, and interplay effects. Proton Arc Therapy (PAT) is an alternative to maintain target coverage, potentially improving organ at risk (OAR) sparing, reducing beam delivery time (BDT), and enhancing patient experience. We aim to perform a systematic plan comparison study between IMPT and energy layer (EL) and spot assignment algorithm – Proton Arc Therapy (ELSA-PAT) to assess its potential for lung cancer treatment. Material and methods: A total of 14 Lung ELSA-PAT plans were compared retrospectively with IMPT plans. 4D worst-case minimax robust optimization was performed, including 84 scenarios (3%, 3 mm). Dosimetry assessment included target (clinical tumor volume [CTV]) and important OARs, on nominal and worst-case scenarios. Most relevant normal tissue complication probabilities (NTCP), target coverage robustness against interplay effect, and BDT were evaluated. Results: CTV D95% and D98% showed no significant difference in comparison. PAT demonstrated better conformality by 66% (p = 0.00012) but delivered a higher heart mean dose (HMD, 23%). There was a 2% increase in NTCP 2-year mortality risk with PAT. Total BDT was comparable among techniques. IMPT was more robust than PAT against interplay effect, considering both D1% (1.0 ± 0.8 Gy vs 1.1 ± 1.4 Gy) and D98% bandwidths (0.9 ± 0.9 Gy vs 1.1 ± 1.3 Gy). Interpretation: Both techniques provide a similar level of dose coverage to the target volume. Although PAT improved dose conformality, higher HMD translated into increased heart toxicity, presumably due to chosen planning methodology and OAR proximity to target. Increased ELs and spots raised PAT BDT, although it could improve daily treatment workflow.
31 January 2025 in Physics and Imaging in Radiation Oncology
Proton therapy for oesophageal cancer is administered over multiple fractions, based on a single pre-treatment image. However, anatomical changes can lead to the deterioration of the treatment plan, necessitating manual replanning. To keep this within limits, increased residual margins are employed. This study aimed to evaluate the proposed automated Online Adaptive Proton Therapy (OAPT) strategies on their capability to reduce the need for manual replanning, while also exploring the possibility of margin reduction. Two automated OAPT methods were examined: Automated Dose Restoration (ADR) and Automated Full Adaptation (AFA). ADR makes use of dose restoration, restoring the original dose map based on the patient's altered anatomy. AFA adapts the contours used for plan optimization by applying a deformation field, not only correcting for density changes, but also for the relative location of organs. A comparative analysis of OAPT strategies, evaluating tumour coverage on 17 patients, was conducted. The nominal results of non-adapted plans with 7 mm residual margins required manual replanning for 18% of the patients. ADR reduced this to 6%, while AFA eliminated the need for manual replanning. With 2 mm margins, 47% of cases required manual replanning. ADR reduced this to 18%, and AFA further reduced it to 11%. The proposed OAPT strategies offered a marked improvement compared to a non-adaptive approach. ADR and AFA significantly reduced the necessity for manual replanning and facilitated the reduction of residual margins, enhancing dose conformity and reducing treatment toxicity.