A concept for the application of a magnetocaloric device in energy-efficient air conditioners is introduced. In order to evaluate this concept, a test stand has been developed equipped with a magnetic field source providing about a 1.5-T flux density change into which different regenerator geometries can be implemented and evaluated. A processing route for the production of profiled magnetocaloric LaFeSiMn-based composite plates by tape casting is presented. The processed plates show a maximum isothermal entropy change of about 3.8 J kg K at a magnetic field change of 1.5 T at 285 K. The hydraulic and thermal performance of regenerator geometries that can be realized by profiled plates is assessed by calculations.
This paper presents a simplified method to compute the frequency dependent coupling resistances inside high current instrument transformers (HCTs). The solution of the one-dimensional Helmholtz equation is used to estimate the losses inside the winding layers dependent on the frequency of the exciting current. The resistive couplings inside the HCT are determined by computing the total winding losses inside the HCT and differentiating the loss equation. An equivalent proximity depth for HCTs is defined by assessing the losses component of skin- and proximity effect. This quantity, which only depends on the skin depth and the number of winding layers, enable to estimate the limit beyond which the proximity effect causes high losses inside the winding. An computation example shows the results of the model.
19 August 2023 in International Journal of Refrigeration