This paper presents a new approach to consider the time-dependent provision of flexibility by RES. In order to achieve an advanced coordination level between grid operators it is essential to consider the increasing penetration of DER, especially at the lower voltage levels. Massive amounts of information are required to reach a complete observability of the grid, therefore, different methodologies to aggregate flexibility within distribution grids have been proposed. In this case, the modelling of Flexibility Providing Units is adapted to consider time-series, while the aggregation process is repeated for several time-steps, which is essential for short-term operation planning of power systems. The proposed method is applied to the European CIGRE MV Grid for two scenarios, a typical summer and winter day. Results show that the load profile over a specific time, the reactive power requirements and the amount of flexibility provided within a grid play major roles in the probability distribution of the operating points of the grid. This has a direct influence on the definition of predefined schedules at the TSO-DSO interconnection point.
With increasing penetration of DER in distribution grids, the use of flexibility provided by these new resources for ancillary services is gaining relevance. Changes in the topology of a distribution grid can influence the provision of flexibility, since grid constraints are modified. Therefore, the impact of operating radial and meshed grids is assessed in this paper. A method to aggregate the flexibility provision within a distribution grid is used to quantify this impact. A case study was performed using the adapted CIGRE MV test-bench grid. The feasible operation region of a grid was calculated under several discrete switching combinations, combined with a transformer with tap changer. Results showed that grids with meshed topologies have an increased ability to provide flexibility, due to the homogenization of power flows among the branches. Critical scenarios were observed in radial structures with large branch distances.
Grid operators are required to ensure the secure and stable operation of the power grid. With increasing penetration of distributed generation in the grid, especially at lower voltage levels, this task is becoming more complex for system operators, leading to the need of an improvement in their coordination efforts. To tackle this issue, different methodologies to present the flexibility provision within a distribution grid in an aggregated manner have been developed. This paper focuses on validating the results provided by such aggregation algorithms. A random sampling approach is used to validate the obtained flexibility range of a distribution grid obtained through a previously developed linear optimal power flow algorithm. By means of a ‘beta’ instead of a ‘uniform’ distribution for the selection of the random variables, the flexibility ranges become comparable and a validation of the results is applicable. A case study is performed using the CIGRE test-bench grid. Results show that optimization-based aggregation algorithms can provide accurate results, while respecting grid constraints and showing a convex behavior.