1 September 2022 in Journal of Instrumentation
The Cooling Storage Ring (CSR) External-target Experiment (CEE) is the first multi-purpose nuclear physics experimental device to operate in the GeV energy range at the Heavy-Ion Research Facility (HIRFL-CSR) in Lanzhou, China.The primary goals of the CEE are to study the bulk properties of dense matter and to understand the quantum chromo-dynamic (QCD) phase diagram by measuring the charged particles produced in heavy-ion collisions at the target region with large acceptance. An inner time of flight (iTOF) system has been proposed to measure the multiplicity, angular distribution, and time information of the charged particles. Herein, we introduce the performance requirements of iTOF according to calculations and GEANT4 simulations. The proposed system is characterized by high granularity and time performance, hence, the conceptual design of the iTOF wall adopts high granularity Multi-gap Resistive Plate Chambers (MRPC) with a time resolution around 30 ps. To evaluate the MRPC design, the cosmic ray test was performed. A timing resolution better than 28 ps and an efficiency better than 98% have been achieved for MIPs, as interpreted by the cosmic ray GEANT4 simulation of time jitter components.
28 March 2020 in The European Physical Journal C
The Cooling Storage Ring (CSR) External-target Experiment (CEE) will be the first large-scale nuclear physics experimental device at the CSR of the Heavy-Ion Research Facility in Lanzhou (HIRFL) in China. A new T0 detector has been proposed to measure the multiplicity, angular distribution and timing information of charged particles produced in heavy-ion collisions at the target region. Multi-gap resistive plate chamber (MRPC) technology was chosen as part of the construction of the T0 detector, which provides precision event collision times (T0) and collision geometry information. The prototype was tested with hadron and heavy-ion beams to study its performance. By comparing the experimental results with a Monte Carlo simulation, the time resolution of the MRPCs are found to be better than $$\sim 50$$ ps. The timing performance of the T0 detector, including both detector and readout electronics, is found to fulfil the requirements of the CEE.
1 January 2011 in Chinese Physics C
The time calibration for end cap TOF system of BES is studied in this paper.It has achieved about 110 ps time resolution for muons in dimu events.The pulse height correction using electronic scan curve and the predicted time calculated using Kalman filter method are introduced.This paper also describes the study of using electrons and muons as calibration samples.
1 June 2017 in Journal of Instrumentation
1 February 2020 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 September 2013 in Chinese Physics C