Phuong Anh Nguyen

Phuong Anh Nguyen

Auto-generated profile, based on publicly available information

Phuong Anh Nguyen

Radiology Center - Bach Mai Hospital

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2023 in Chemical Engineering Journal
Verified
Journal Article
Open access
PNPhuong Anh Nguyen
Phuong Anh Nguyen
Quang DaoQuang Dao
Quang Dao
TDThanh Truong Dang
Thanh Truong Dang
THThi Van Anh Hoang
Thi Van Anh Hoang
JCJin Suk Chung
Jin Suk Chung
ESEun Woo Shin
Eun Woo Shin

22 April 2026 in Journal of CO2 Utilization
Verified
Journal Article
Open access
NPNhiem Pham-Ngoc
Nhiem Pham-Ngoc
GJGa Eun Jo
Ga Eun Jo
PNPhuong Anh Nguyen
Phuong Anh Nguyen
AJAzam Jamsaz
Azam Jamsaz
BLByung Jin Lee
Byung Jin Lee
ESEun Woo Shin
Eun Woo Shin

30 December 2022 in Vietnamese Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
PDF file
NTNgọc Mai Thị
Ngọc Mai Thị
TDThuy Trang Dam
Thuy Trang Dam
TNThi Thu Thao Nguyen
Thi Thu Thao Nguyen
TNThanh Thuy Nguyen
Thanh Thuy Nguyen
PNPhuong Anh Nguyen
Phuong Anh Nguyen
LVLuu Vu
Luu Vu
This study focused on evaluating the diagnostic performance of the lung point (LP)- a lung ultrasound (LUS) sign in detecting and semi-quantifying pneumothorax (PTX), using computed tomography (CT) as the reference standard. The study included 150 patients who underwent CT-guided transthoracic biopsy (TTB) for lung lesions. Two radiologists blinded to the participant’s prior information performed LUS post-biopsy. The results showed that PTX was present on CT in 49/150 (32.3%) cases. The LP was positive in 36/150 (24%) patients, with a substantial agreement between the two radiologists (Cohen κ statistics = 0.8). The sensitivity and specificity of the LP were 73.5% (95%CI 66.5% to 80.5) and 100% (95%CI 97.6% to 100%), respectively. Moreover, the positive and negative predictive values were 100% (95%CI 97.6% to 100%) and 67.3% (95%CI 59.8% to 78.4%), respectively. In the semi-quantification of PTX, the location of LP was described in 36/49 (73.5%) patients. The sensitivity and specificity of this sign were 87.5% (95%CI 82.2% to 92.8%) and 96.4% (95%CI 92.4% to 98.9%), respectively. The positive and negative predictive values were 87.5% (95%CI 82.2% to 92.8%) and 96.4% (95%CI 92.4% to 98.9%), respectively. In conclusion, LP is a susceptible and specific LUS sign for diagnosing and semi-quantifying PTX.