Jake A. Carter

Jake A. Carter

Auto-generated profile, based on publicly available information

Jake A. Carter

Department of Chemistry, Wake Forest University, Salem Hall, Box 7486, Winston-Salem, NC, 27109, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2018 in Frontiers in Chemistry
Verified
Journal Article
Open access
PDF file
JCJake A. Carter
Jake A. Carter
ABAriane I. Barros
Ariane I. Barros
JNJoaquim A. Nóbrega
Joaquim A. Nóbrega
GDGeorge L. Donati
George L. Donati
Applications, advantages, and limitations of the traditional external standard calibration, matrix-matched calibration, internal standardization, and standard additions, as well as the non-traditional interference standard method, standard dilution analysis, multi-isotope calibration, and multispecies calibration methods are discussed.

13 December 2018 in Chemistry of Materials
Verified
Journal Article
Closed access
CLChang Lu
Chang Lu
MWMarcus W. Wright
Marcus W. Wright
XMXiao Ma
Xiao Ma
HLHui Li
Hui Li
DIDominique S. Itanze
Dominique S. Itanze
SGScott M. Geyer
Scott M. Geyer

1 January 2019 in Expert Systems with Applications
Verified
Journal Article
Closed access
JCJake A. Carter
Jake A. Carter
CLChristina S. Long
Christina S. Long
BSBeth P. Smith
Beth P. Smith
TSThomas L. Smith
Thomas L. Smith
GDGeorge L. Donati
George L. Donati

1 February 2021 in Talanta
Verified
Journal Article
Closed access
JCJake A. Carter
Jake A. Carter
LOLogan M. O'Brien
Logan M. O'Brien
THTina Harville
Tina Harville
BJBradley T. Jones
Bradley T. Jones
GDGeorge L. Donati
George L. Donati

12 April 2019 in Journal of Trace Elements in Medicine and Biology
Verified
Journal Article
Closed access
JSJohn T. Sloop
John T. Sloop
JCJake A. Carter
Jake A. Carter
UBUlrich Bierbach
Ulrich Bierbach
BJBradley T. Jones
Bradley T. Jones
GDGeorge L. Donati
George L. Donati

25 February 2020 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
JCJake A. Carter
Jake A. Carter
JSJohn T. Sloop
John T. Sloop
THTina Harville
Tina Harville
BJBradley T. Jones
Bradley T. Jones
GDGeorge L. Donati
George L. Donati
A supervised data-driven methodology was used to evaluate matrix effect severity and the consequent analytical signal bias caused by easily ionizable elements (EIEs) in inductively coupled plasma optical emission spectrometry (ICP OES). Eight different supervised machine learning models were trained on signals from nine plasma naturally-occurring species of Ar, H and O to predict analyte recoveries for Cd, Co, Cr and Pb. The Ar atomic line at 737.212 nm was then used to correct for analytical signal bias due to matrix effects caused by high concentrations of Ca and Na. Recoveries were accurately predicted for all analytes (R2 > 0.9) by optimized generalized linear models (GLMs), regularized GLMs and partial least squares (PLS) regression. Accuracy was improved by employing Ar or Y as internal standards (IS). Although Y outperformed Ar in Cd determinations, both species were comparable for Co, Cr and Pb. In this preliminary study, however, there was no significant accuracy improvement observed when utilizing the Ar 737.212 nm line at the discretion of machine learning models. Therefore, for the analytes and matrices evaluated here, this species should be simply used as an IS when optimized models predict absolute errors < 0.3 (30%). The methodology described in this study may be easily implemented in routine applications, as one simply needs to monitor non-analyte signals while performing external standard calibration (EC). Once a series of models are trained, instrument software can be programmed to monitor plasma native species in real time and alert the analyst to different levels of matrix effect severity. Based on analyte recovery predictions from the optimized models, the analyst can then choose between simple EC, internal standardization with the Ar 737.212 nm line, or a more robust matrix-matching strategy.