Yasar Islamoglu

Yasar Islamoglu

Auto-generated profile, based on publicly available information

Yasar Islamoglu

Mechanical Engineering Department, Thermoelectric Systems-Heat Transfer Laboratory, Sakarya University, Esentepe Campus, Serdivan, Turkey

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2015 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
EAErman Aslan
Erman Aslan
ITImdat Taymaz
Imdat Taymaz
YIYasar Islamoglu
Yasar Islamoglu

1 August 2022 in IEEE Access
Verified
Journal Article
Open access
UYUgur Yilmaz
Ugur Yilmaz
TÇTürker Fedai ÇAVUŞ
Türker Fedai ÇAVUŞ
YIYasar Islamoglu
Yasar Islamoglu
This paper presents a complete model for thermoelectric modules (TEMs) in order to be used in circuit simulations in MATLAB/Simulink software. The purpose of this study is to develop a single block like other circuit elements in the Simulink library by combining both thermoelectric generator (TEG) and thermoelectric cooler (TEC) module parameters and their operations. Since TEG and TEC are both thermoelectric devices, mostly whose main material, such as Bi2Te3, is the same for similar temperature ranges, a TEG can be operated as TEC and vice versa a TEC can be operated as TEG. In some systems, such as PV-thermoelectric (TE), fuel cell-TE, and battery temperature management of electric vehicles, the modules can be used in both modes. Also, in some cases of these systems, sometimes the TEM may need to be operated as a generator, and sometimes as a cooler. The bidirectional operation of the TEM is a cost-saving approach since the 2 types of TEMs are not needed to be installed together. This paper proposes a novel model whereas the studies up to date in the literature have not been fully compatible with the bidirectional usage of the modules. The proposed model deals with the polarities of both the thermal and the electrical ports of the TEM in order to decide the mode of operation, that is TEG or TEC. Maximum parameters and performance parameters for both TEG and TEC operations are included in the module block so as to observe and control the device for desired operating conditions. It is seen that the simulations with the temperature-dependent parameters have given very close results to the graphics of the datasheet. However, simulations in which the Thomson heat isn’t ignored have more deviations compared to the datasheet. Moreover, the simulations with the constant material properties have given better results than the Thomson heat included ones in the cases of the higher ΔT levels. While ΔT is 10 °K, COPmax without the Thomson heat has been found as 3.399 which is the same as the datasheet. Meanwhile, COPmax with the Thomson heat has been found as 3.7147, and COPmax with the constant properties has been found as 3.8057. However; while ΔT is 50 °K, COPmax is 0.247 without the Thomson heat which is the same as the datasheet, but COPmax is 0.341 with the Thomson heat, and COPmax is 0.268 with constant material properties. In addition, it is shown that, under variable polarities of thermal and electrical ports, bidirectional operation of the TEM is successfully achieved and the TEM is operated as both TEG and TEC in the same simulation.

1 October 2020 in Sakarya University Journal of Science
Verified
Journal Article
Closed access
YİYaşar İSLAMOĞLU
Yaşar İSLAMOĞLU
ITİmDat Taymaz
İmDat Taymaz
CPCem Parmaksizoğlu
Cem Parmaksizoğlu
MÖMurat Özsoy
Murat Özsoy
EAErman Aslan
Erman Aslan
A thermoelectric generator system has a potential to transform waste heat into electricity. Equate to other technologies of waste heat recover, usage of thermoelectric generators (TEGs) in a waste heat recovery system has many attractive features, for example quite operation, no moving parts, small size and endurance In addition to, thermoelectric generators are environmentally friendly materials that convert thermal energy directly into electricity by Seebeck effect. In work presented, a heat pipe assisted thermoelectric generator system is designed to generate electricity from the waste heat. Usage of heat pipes can latently decrease the thermal resistance and pressure losses in the system as well as temperature regulation of the TEGs and enhanced design flexibility. The designed system is suitable for the heat recovery from the piped systems such as the exhaust and the cylindrical chimney systems. The power performance of the designed thermoelectric generator system has been determined both theoretically and experimentally.

26 April 2022 in Heat Transfer Engineering
Verified
Journal Article
Closed access
ZPZekeriya Parlak
Zekeriya Parlak
NPNezaket PARLAK
Nezaket PARLAK
YIYaşar Islamoğlu
Yaşar Islamoğlu
UDUfuk Durmaz
Ufuk Durmaz
In the present work, a parametric numerical study is performed for a converging–diverging channel under pulsatile flow conditions. The sinusoidal velocity at the channel entrance provides the pulsatile flow condition. Simulations are performed for transient flow in the range of 0.001 − 0.5 for the Strouhal numbers, 3400 − 6500 for the Reynolds numbers, and 0.025 − 0.5 for the nondimensionalized amplitude values. The thermal–hydraulic performance is reported to compare pulsatile flow conditions with non-pulsatile conditions. The numerical results showed that the Nusselt number decreased as the Strouhal number and nondimensionalized amplitude values increased. In addition, an improvement in heat transfer is observed in pulsatile conditions for the Reynolds number range 3400–5200. It is understood that turbulent pulsatile airflow in a converging–diverging duct has a limited potential for heat transfer improvement in a specific range. The maximum thermal–hydraulic performance coefficient is found to be 1.17 for the Reynolds number of 3412 and for the Strouhal number of 0.001. It is concluded that pulsatile flow provides satisfactory improvement at lower Reynolds numbers than non-pulsatile flow. Moreover, pulsatile airflow in a converging–diverging duct has a limited potential for the heat transfer improvement in a specific range.