Bryan J. Caldwell

Bryan J. Caldwell

Auto-generated profile, based on publicly available information

Bryan J. Caldwell

Auckland Bioengineering Institute, University of Auckland, New Zealand

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2007 in Circulation Research
Verified
Journal Article
Closed access
PDF file
DHDarren A. Hooks
Darren A. Hooks
MTMark L. Trew
Mark L. Trew
BCBryan J. Caldwell
Bryan J. Caldwell
GSGregory B. Sands
Gregory B. Sands
ILIan J. LeGrice
Ian J. LeGrice
BSBruce H. Smaill
Bruce H. Smaill
The response of the heart to electrical shock, electrical propagation in sinus rhythm, and the spatiotemporal dynamics of ventricular fibrillation all depend critically on the electrical anisotropy of cardiac tissue. A long-held view of cardiac electrical anisotropy is that electrical conductivity is greatest along the myocyte axis allowing most rapid propagation of electrical activation in this direction, and that conductivity is isotropic transverse to the myocyte axis supporting a slower uniform spread of activation in this plane. In this context, knowledge of conductivity in two directions, parallel and transverse to the myofiber axis, is sufficient to characterize the electrical action of the heart. Here we present new experimental data that challenge this view. We have used a novel combination of intramural electrical mapping, and experiment-specific computer modeling, to demonstrate that left ventricular myocardium has unique bulk conductivities associated with three microstructurally-defined axes. We show that voltage fields induced by intramural current injection are influenced by not only myofiber direction, but also the transmural arrangement of muscle layers or myolaminae. Computer models of these experiments, in which measured 3D tissue structure was reconstructed in-silico, best matched recorded voltages with conductivities in the myofiber direction, and parallel and normal to myolaminae, set in the ratio 4:2:1, respectively. These findings redefine cardiac tissue as an electrically orthotropic substrate and enhance our understanding of how external shocks may act to successfully reset the fibrillating heart into a uniform electrical state. More generally, the mechanisms governing the destabilization of coordinated electrical propagation into ventricular arrhythmia need to be evaluated in the light of this discovery.

1 August 2009 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
BCBryan J. Caldwell
Bryan J. Caldwell
MTMark L. Trew
Mark L. Trew
GSGregory B. Sands
Gregory B. Sands
DHDarren A. Hooks
Darren A. Hooks
ILIan J. LeGrice
Ian J. LeGrice
BSBruce H. Smaill
Bruce H. Smaill
The anisotropy of cardiac tissue is a key determinant of 3D electric propagation and the stability of activation wave fronts in the heart. The electric properties of ventricular myocardium are widely assumed to be axially anisotropic, with activation propagating most rapidly in the myofiber direction and at uniform velocity transverse to this. We present new experimental evidence that contradicts this view. For the first time, high-density intramural electric mapping (325 electrodes at approximately 4x4x1-mm spacing) from pig left ventricular tissue was used to reconstruct 3D paced activation surfaces projected directly onto 3D tissue structure imaged throughout the same left ventricular volume. These data from 5 hearts demonstrate that ventricular tissue is electrically orthotropic with 3 distinct propagation directions that coincide with local microstructural axes defined by the laminar arrangement of ventricular myocytes. The maximum conduction velocity of 0.67+/-0.019 ms(-1) was aligned with the myofiber axis. However, transverse to this, the maximum conduction velocity was 0.30+/-0.010 ms(-1), parallel to the myocyte layers and 0.17+/-0.004 ms(-1) normal to them. These orthotropic conduction velocities give rise to preferential activation pathways across the left ventricular free wall that are not captured by structurally detailed computer models, which incorporate axially anisotropic electric properties. Our findings suggest that current views on uniform side-to-side electric coupling in the heart need to be revised. In particular, nonuniform laminar myocardial architecture and associated electric orthotropy should be included in future models of initiation and maintenance of ventricular arrhythmia.

27 July 2007 in Microscopy Research and Technique
Verified
Journal Article
Closed access
PDF file
DGDane A. Gerneke
Dane A. Gerneke
GSGregory B. Sands
Gregory B. Sands
RGRamanujan Ganesalingam
Ramanujan Ganesalingam
PJPurva Joshi
Purva Joshi
BCBryan J. Caldwell
Bryan J. Caldwell
ILIan J. Legrice
Ian J. Legrice

3 March 2006 in Experimental Physiology
Verified
Journal Article
Open access
PDF file
MTMark L. Trew
Mark L. Trew
BCBryan J. Caldwell
Bryan J. Caldwell
GSGregory B. Sands
Gregory B. Sands
DHDarren A. Hooks
Darren A. Hooks
DTDean C.‐S. Tai
Dean C.‐S. Tai
BSBruce H. Smaill
Bruce H. Smaill
Significant tissue structures exist in cardiac ventricular tissue that are of supracellular dimension. It is hypothesized that these tissue structures contribute to the discontinuous spread of electrical activation, may contribute to arrhymogenesis and also provide a substrate for effective cardioversion. However, the influences of these mesoscale tissue structures in intact ventricular tissue are difficult to understand solely on the basis of experimental measurement. Current measurement technology is able to record at both the macroscale tissue level and the microscale cellular or subcellular level, but to date it has not been possible to obtain large volume, direct measurements at the mesoscales. To bridge this scale gap in experimental measurements, we use tissue‐specific structure and mathematical modelling. Our models have enabled us to consider key hypotheses regarding discontinuous activation. We also consider the future developments of our intact tissue experimental programme.

1 September 2004 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
DTDean C.-S. Tai
Dean C.-S. Tai
BCBryan J. Caldwell
Bryan J. Caldwell
ILIan J. LeGrice
Ian J. LeGrice
DHDarren A. Hooks
Darren A. Hooks
APAndrew J. Pullan
Andrew J. Pullan
BSBruce H. Smaill
Bruce H. Smaill
Fast voltage-sensitive dyes are widely used to image cardiac electrical activity. Typically, the emission spectrum of these fluorochromes is wavelength shifted with altered membrane potential, but the optical signals obtained also decay with time and are affected by contraction. Ratiometry reduces, but may not fully remove, these artifacts. An alternate approach has been developed in which the time decay in simultaneously acquired short- and long-wavelength signals is characterized nonparametrically and removed. Motion artifact is then identified as the time-varying signal component common to both decay-corrected signals and subtracted. Performance of this subtraction technique was compared with ratiometry for intramural optical signals acquired with a fiber-optic probe in an isolated, Langendorff-perfused pig heart preparation ( n = 4) stained with di-4-ANEPPS. Perfusate concentration of 2,3-butanedione monoxime was adjusted (7.5–12.5 mM) to alter contractile activity. Short-wavelength (520–600 nm) and long-wavelength (>600 nm) signals were recorded over 8–16 cardiac cycles at 6 sites across the left ventricular free wall in sinus rhythm and during pacing. A total of 451 such data sets were acquired. Appreciable wall motion was observed in 225 cases, with motion artifact classed as moderate (less than modulation due to action potential) in 187 and substantial (more than modulation due to action potential) in 38. In all cases, subtraction performed as well as, or better than, ratiometry in removing motion artifact and decay. Action potential morphology was recovered more faithfully by subtraction than by ratiometry in 58 of 187 and 31 of 38 cases with moderate and substantial motion artifact, respectively. This novel subtraction approach may therefore provide a means of reducing the concentration of uncoupling agents used in cardiac optical mapping studies.

31 August 2005 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
BCBryan J. Caldwell
Bryan J. Caldwell
ILIan J. Legrice
Ian J. Legrice
DHDarren A. Hooks
Darren A. Hooks
DTDean C.‐S. Tai
Dean C.‐S. Tai
APAndrew J. Pullan
Andrew J. Pullan
BSBruce H. Smaill
Bruce H. Smaill