Zaki Ahmed

Zaki Ahmed

Auto-generated profile, based on publicly available information

Zaki Ahmed

Corewell Health William Beaumont University Hospital Royal Oak Michigan USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2021 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
EDElizabeth DuPre
Elizabeth DuPre
TSTaylor Salo
Taylor Salo
ZAZaki Ahmed
Zaki Ahmed
PBPeter A. Bandettini
Peter A. Bandettini
KBKatherine L. Bottenhorn
Katherine L. Bottenhorn
DHDaniel A. Handwerker
Daniel A. Handwerker

13 October 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
BDBen R. Dickie
Ben R. Dickie
ZAZaki Ahmed
Zaki Ahmed
JAJonathan Arvidsson
Jonathan Arvidsson
LBLaura C. Bell
Laura C. Bell
DBDavid L. Buckley
David L. Buckley
OIon behalf of The Perfusion Study Group of the ISMRM
on behalf of The Perfusion Study Group of the ISMRM
This manuscript describes the ISMRM OSIPI (Open Science Initiative for Perfusion Imaging) lexicon for dynamic contrast‐enhanced and dynamic susceptibility‐contrast MRI. The lexicon was developed by Taskforce 4.2 of OSIPI to provide standardized definitions of commonly used quantities, models, and analysis processes with the aim of reducing reporting variability. The taskforce was established in February 2020 and consists of medical physicists, engineers, clinicians, data and computer scientists, and DICOM (Digital Imaging and Communications in Medicine) standard experts. Members of the taskforce collaborated via a slack channel and quarterly virtual meetings. Members participated by defining lexicon items and reporting formats that were reviewed by at least two other members of the taskforce. Version 1.0.0 of the lexicon was subject to open review from the wider perfusion imaging community between January and March 2022, and endorsed by the Perfusion Study Group of the ISMRM in the summer of 2022. The initial scope of the lexicon was set by the taskforce and defined such that it contained a basic set of quantities, processes, and models to enable users to report an end‐to‐end analysis pipeline including kinetic model fitting. We also provide guidance on how to easily incorporate lexicon items and definitions into free‐text descriptions (e.g., in manuscripts and other documentation) and introduce an XML‐based pipeline encoding format to encode analyses using lexicon definitions in standardized and extensible machine‐readable code. The lexicon is designed to be open‐source and extendable, enabling ongoing expansion of its content. We hope that widespread adoption of lexicon terminology and reporting formats described herein will increase reproducibility within the field.

19 December 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
ESEve S. Shalom
Eve S. Shalom
HKHarrison Kim
Harrison Kim
RHRianne A. van der Heijden
Rianne A. van der Heijden
ZAZaki Ahmed
Zaki Ahmed
RPReyna Patel
Reyna Patel
AKAnahita Fathi Kazerooni
Anahita Fathi Kazerooni
Purpose: has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.Methods: A framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.Results: Across the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.Conclusions: This study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.

27 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
DKDaehun Kang
Daehun Kang
MIMyung-Ho In
Myung-Ho In
HJHang Joon Jo
Hang Joon Jo
MHMaria A. Halverson
Maria A. Halverson
NMNolan K. Meyer
Nolan K. Meyer
YSYunhong Shu
Yunhong Shu
In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.

1 April 2018 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
MVMartin Vallières
Martin Vallières
MSMonica Serban
Monica Serban
IBIbtissam Benzyane
Ibtissam Benzyane
ZAZaki Ahmed
Zaki Ahmed
SXShu Xing
Shu Xing
CFCarolyn R. Freeman
Carolyn R. Freeman
In this work, we validate a texture-based model computed from positron emission tomography (PET) and magnetic resonance imaging (MRI) for the prediction of lung metastases in soft-tissue sarcomas (STS). We explore functional imaging at different treatment time points and evaluate the feasibility of radiotherapy dose painting as a potential treatment strategy for patients with higher metastatic risk. We acquired fluorodeoxyglucose (FDG)-PET, fluoromisonidazole (FMISO)-PET, diffusion weighting (DW)-MRI and dynamic contrast enhanced (DCE)-MRI data for 18 patients with extremity STS before, during, and after pre-operative radiotherapy. We tested the lung metastases prediction model using pre-treatment images. We evaluated the feasibility of dose painting using volumetric arc therapy (VMAT) via treatment re-planning with a prescription of 50 Gy to the planning target volume (PTV50Gy) and boost doses of 60 Gy to the FDG hypermetabolic gross tumour volume (GTV60Gy) and 65 Gy to the low-perfusion DCE-MRI hypoxic GTV contained within the GTV60Gy (GTV65Gy). The texture-based model for lung metastases prediction reached an area under the curve (AUC), sensitivity, specificity and accuracy of 0.71, 0.75, 0.85 and 0.82, respectively. Dose painting resulted in adequate coverage and homogeneity in the re-planned treatments: D95% to the PTV50Gy, GTV60Gy and GTV65Gy were 50.0 Gy, 60.3 Gy and 65.4 Gy, respectively. Textural biomarkers extracted from FDG-PET and MRI could be useful to identify STS patients that might benefit from dose escalation. The feasibility of treatment planning with double boost levels to intratumoural GTV functional sub-volumes was established.

10 May 2018 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
ZAZaki Ahmed
Zaki Ahmed
ILIves R. Levesque
Ives R. Levesque