Ranald Iain Mackay

Ranald Iain Mackay

Auto-generated profile, based on publicly available information

Ranald Iain Mackay

Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2011 in British Journal of Cancer
Verified
Journal Article
Open access
PDF file
KHKevin Harrington
Kevin Harrington
LBL J Billingham
L J Billingham
TBT B Brunner
T B Brunner
NBN G Burnet
N G Burnet
CCC S Chan
C S Chan
TITimothy Illidge
Timothy Illidge
Guidelines for preclinical and early phase clinical assessment of novel radiosensitisers

26 September 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
TMT E Marchant
T E Marchant
CMC J Moore
C J Moore
CRC G Rowbottom
C G Rowbottom
RMR I MacKay
R I MacKay
PWP C Williams
P C Williams
Cone-beam CT (CBCT) images have recently become an established modality for treatment verification in radiotherapy. However, identification of soft-tissue structures and the calculation of dose distributions based on CBCT images is often obstructed by image artefacts and poor consistency of density calibration. A robust method for voxel-by-voxel enhancement of CBCT images using a priori knowledge from the planning CT scan has been developed and implemented. CBCT scans were enhanced using a low spatial frequency grey scale shading function generated with the aid of a planning CT scan from the same patient. This circumvents the need for exact correspondence between CBCT and CT and the process is robust to the appearance of unshared features such as gas pockets. Enhancement was validated using patient CBCT images. CT numbers in regions of fat and muscle tissue in the processed CBCT were both within 1% of the values in the planning CT, as opposed to 10-20% different for the original CBCT. Visual assessment of processed CBCT images showed improvement in soft-tissue visibility, although some cases of artefact introduction were observed.

25 February 2021 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
BRBethany Rothwell
Bethany Rothwell
NKNorman F Kirkby
Norman F Kirkby
MMMichael Merchant
Michael Merchant
ACAmy L Chadwick
Amy L Chadwick
MLMatthew Lowe
Matthew Lowe
KKKaren J Kirkby
Karen J Kirkby
There has been a recent revival of interest in the FLASH effect, after experiments have shown normal tissue sparing capabilities of ultra-high-dose-rate radiation with no compromise on tumour growth restraint. A model has been developed to investigate the relative importance of a number of fundamental parameters considered to be involved in the oxygen depletion paradigm of induced radioresistance. An example eight-dimensional parameter space demonstrates the conditions under which radiation may induce sufficient depletion of oxygen for a diffusion-limited hypoxic cellular response. Initial results support experimental evidence that FLASH sparing is only achieved for dose rates on the order of tens of Gy s −1 or higher, for a sufficiently high dose, and only for tissue that is slightly hypoxic at the time of radiation. We show that the FLASH effect is the result of a number of biological, radiochemical and delivery parameters. Also, the threshold dose for a FLASH effect occurring would be more prominent when the parameterisation was optimised to produce the maximum effect. The model provides a framework for further FLASH-related investigation and experimental design. An understanding of the mechanistic interactions producing an optimised FLASH effect is essential for its translation into clinical practice.

1 November 2018 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
WBWilliam Beasley
William Beasley
MTMaria Thor
Maria Thor
AMAlan McWilliam
Alan McWilliam
AGAndrew Green
Andrew Green
RMRanald Mackay
Ranald Mackay
MHMarcel van Herk
Marcel van Herk


17 November 2017 in Nanoscale
Verified
Journal Article
Open access
PDF file
MSMarios Sotiropoulos
Marios Sotiropoulos
NHNicholas T Henthorn
Nicholas T Henthorn
JWJohn W Warmenhoven
John W Warmenhoven
RMRanald I. Mackay
Ranald I. Mackay
KKKaren J. Kirkby
Karen J. Kirkby
MMMichael Merchant
Michael Merchant
Gold nanoparticles have been proven as potential radiosensitizer when combined with protons. Initially the radiosensitization effect was attributed to the physical interactions of radiation with the gold and the production of secondary electrons that induce DNA damage. However, emerging data challenge this hypothesis, supporting the existence of alternative or supplementary radiosensitization mechanisms. In this work we incorporate a realistic cell model with detailed DNA geometry and a realistic gold nanoparticle biodistribution based on experimental data. The DNA single and double strand breaks, and damage complexity are counted under various scenarios of different gold nanoparticle size, biodistribution and concentration, and proton energy. The locality of the effect, i.e. the existence of higher damage at a location close to the gold distribution, is also addressed by investigating the DNA damage at a chromosomal territory. In all the cases we do not observe any significant increase in the single/double strand break yield or damage complexity in the presence of gold nanoparticles under proton irradiation; nor there is a locality to the effect. Our results show for the first time that the physical interactions of protons with the gold nanoparticles should not be considered directly responsible for the observed radiosensitization effect. The model used only accounts for DNA damage from direct interactions, whilst considering the indirect effect, and it is possible the radiosensitization effect to be due to other physical effects, although we consider that possibility unlikely. Our conclusion suggests that other mechanisms might have greater contribution to the radiosensitization effect and further investigation should be conducted.