7 September 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
The highly complementary information provided by multispectral optoacoustics and pulse-echo ultrasound have recently prompted development of hybrid imaging instruments bringing together the unique contrast advantages of both modalities. In the hybrid optoacoustic ultrasound (OPUS) combination, images retrieved by one modality may further be used to improve the reconstruction accuracy of the other. In this regard, image segmentation plays a major role as it can aid improving the image quality and quantification abilities by facilitating modeling of light and sound propagation through the imaged tissues and surrounding coupling medium. Here we propose an automated approach for surface segmentation in whole-body mouse OPUS imaging using a deep convolutional neural network (CNN). The method has shown robust performance, attaining accurate segmentation of the animal boundary in both optoacoustic and pulseecho ultrasound images, as evinced by quantitative performance evaluation using Dice coefficient metrics.
28 October 2023 in Medical Image Analysis
Optoacoustic (OA) imaging is based on optical excitation of biological tissues with nanosecond-duration laser pulses and detection of ultrasound (US) waves generated by thermoelastic expansion following light absorption. The image quality and fidelity of OA images critically depend on the extent of tomographic coverage provided by the US detector arrays. However, full tomographic coverage is not always possible due to experimental constraints. One major challenge concerns an efficient integration between OA and pulse-echo US measurements using the same transducer array. A common approach toward the hybridization consists in using standard linear transducer arrays, which readily results in arc-type artifacts and distorted shapes in OA images due to the limited angular coverage. Deep learning methods have been proposed to mitigate limited-view artifacts in OA reconstructions by mapping artifactual to artifact-free (ground truth) images. However, acquisition of ground truth data with full angular coverage is not always possible, particularly when using handheld probes in a clinical setting. Deep learning methods operating in the image domain are then commonly based on networks trained on simulated data. This approach is yet incapable of transferring the learned features between two domains, which results in poor performance on experimental data. Here, we propose a signal domain adaptation network (SDAN) consisting of i) a domain adaptation network to reduce the domain gap between simulated and experimental signals and ii) a sides prediction network to complement the missing signals in limited-view OA datasets acquired from a human forearm by means of a handheld linear transducer array. The proposed method showed improved performance in reducing limited-view artifacts without the need for ground truth signals from full tomographic acquisitions.
1 December 2020 in Neoplasia
Development of imaging methods capable of furnishing tumor-specific morphological, functional, and molecular information is paramount for early diagnosis, staging, and treatment of breast cancer. Ultrasound (US) and optoacoustic (OA) imaging methods exhibit excellent traits for tumor imaging in terms of fast imaging speed, ease of use, excellent contrast, and lack of ionizing radiation. Here, we demonstrate simultaneous tomographic whole body imaging of optical absorption, US reflectivity, and speed of sound (SoS) in living mice. In vivo studies of 4T1 breast cancer xenografts models revealed synergistic and complementary value of the hybrid imaging approach for characterizing mammary tumors. While neovasculature surrounding the tumor areas were observed based on the vascular anatomy contrast provided by the OA data, the tumor boundaries could be discerned by segmenting hypoechoic structures in pulse-echo US images. Tumor delineation was further facilitated by enhancing the contrast and spatial resolution of the SoS maps with a full-wave inversion method. The malignant lesions could thus be distinguished from other hypoechoic regions based on the average SoS values. The reported findings corroborate the strong potential of the hybrid imaging approach for advancing cancer research in small animal models and fostering development of new clinical diagnostic approaches.
1 August 2021 in NeuroImage
Intense efforts are underway to develop functional imaging modalities for capturing brain activity at the whole organ scale with high spatial and temporal resolution. Functional optoacoustic (fOA) imaging is emerging as a new tool to monitor multiple hemodynamic parameters across the mouse brain, but its sound validation against established neuroimaging modalities is often lacking. Here we investigate mouse brain responses to peripheral sensory stimulation using both fOA and functional ultrasound (fUS) imaging. The two modalities operate under similar spatio-temporal resolution regime, with a potential to provide synergistic and complementary hemodynamic readouts. Specific contralateral activation was observed with sub-millimetre spatial resolution with both methods. Sensitivity to hemodynamic activity was found to be on comparable levels, with the strongest responses obtained in the oxygenated hemoglobin channel of fOA. While the techniques attained highly correlated hemodynamic responses, the differential fOA readings of oxygenated and deoxygenated haemoglobin provided complementary information to the blood flow contrast of fUS. The multi-modal approach may thus emerge as a powerful tool providing new insights into brain function, complementing our current knowledge generated with well-established neuroimaging methods.
4 May 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Reflection ultrasound computed tomography (RUCT) attains optimal image quality from objects that can be fully accessed from multiple directions, such as the human breast or small animals. Owing to the full-view tomography approach based on the compounding of images taken from multiple angles, RUCT effectively mitigates several deficiencies afflicting conventional pulse-echo ultrasound (US) systems, such as speckle patterns and interuser variability. On the other hand, the small interelement pitch required to fulfill the spatial sampling criterion in the circular transducer configuration used in RUCT typically implies the use of an excessive number of independent array elements. This increases the system’s complexity and costs, and limits the achievable imaging speed. Here, we explore acquisition schemes that enable RUCT imaging with the reduced number of transmit/receive elements. We investigated the influence of the element size in transmission and reception in a ring array geometry. The performance of a sparse acquisition approach based on partial acquisition from a subset of the elements has been further assessed. A larger element size is shown to preserve contrast and resolution at the center of the field of view (FOV), while a reduced number of elements is shown to cause uniform loss of contrast and resolution across the entire FOV. The tradeoffs of achievable FOV, contrast-to-noise ratio, and temporal and spatial resolutions are assessed in phantoms and in vivo mouse experiments. The experimental analysis is expected to aid the development of optimized hardware and image acquisition strategies for RUCT and, thus, result in more affordable imaging systems facilitating wider adoption.
18 June 2021 in Optics Letters
Images rendered with common optoacoustic system implementations are often afflicted with distortions and poor visibility of structures, hindering reliable image interpretation and quantification of bio-chrome distribution. Among the practical limitations contributing to artifactual reconstructions are insufficient tomographic detection coverage and suboptimal illumination geometry, as well as inability to accurately account for acoustic reflections and speed of sound heterogeneities in the imaged tissues. Here we developed a convolutional neural network (CNN) approach for enhancement of optoacoustic image quality which combines training on both time-resolved signals and tomographic reconstructions. Reference human finger data for training the CNN were recorded using a full-ring array system that provides optimal tomographic coverage around the imaged object. The reconstructions were further refined with a dedicated algorithm that minimizes acoustic reflection artifacts induced by acoustically mismatch structures, such as bones. The combined methodology is shown to outperform other learning-based methods solely operating on image-domain data.