Ioan-Ovidiu Neaga

Ioan-Ovidiu Neaga

Auto-generated profile, based on publicly available information

Ioan-Ovidiu Neaga

Laboratory of Pharmaceutical Analysis, Faculty of Medicine and Pharmacy, Research Institute for Health Sciences and Technology, University of Mons, Place du Parc 20, 7000, Mons, Belgium

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Polymer Degradation and Stability
Verified
Journal Article
Closed access
TKTímea Kacsó
Tímea Kacsó
INIoan O. Neaga
Ioan O. Neaga
AEArnold Erincz
Arnold Erincz
CACarlos E. Astete
Carlos E. Astete
CSCristina M. Sabliov
Cristina M. Sabliov
Ede BodokiEde Bodoki
Ede Bodoki

1 February 2016 in Talanta
Verified
Journal Article
Closed access
INI.O. Neaga
I.O. Neaga
Ede BodokiEde Bodoki
Ede Bodoki
SHS. Hambye
S. Hambye
BBB. Blankert
B. Blankert
RORadu Oprean
Radu Oprean

3 April 2014 in Journal of Liquid Chromatography & Related Technologies
Verified
Journal Article
Closed access
INIoan-Ovidiu Neaga
Ioan-Ovidiu Neaga
BIBogdan Cezar Iacob
Bogdan Cezar Iacob
Ede BodokiEde Bodoki
Ede Bodoki
Simultaneous electrophoretic separation of inorganic anions and cations from ground waters by dual opposite end injection and their capacitively coupled contactless conductometric detection is described. The chemometry assisted method development revealed that using this type of detection, apart from many advantages, implies a careful fine tuning of experimental variables. Proper choice of buffer components is the most critical aspect of the recorded signal's quality and the obtained resolution, where minor changes could lead to major changes in the recorded electropherograms. From a big variety of acidic and basic electrolytes, a pyromellitic acid/citric acid based buffer (pH = 3.70) was chosen for the baseline separation of 11 cations and anions in a single, less than 3 min run, using a PVA coated fused silica capillary. The estimated limits of detection (0.07–2 ppm) and defined limits of quantification (0.3–7 ppm) were comparable or better than those described for indirect UV detection, allowing much broader linear ranges (up to 120 ppm) for most of the studied ions. Following method validation the method was successfully applied for the assessment of inorganic ion content of 51 geotagged drinking water (domestic well) samples collected from the rural area of Cluj County, Romania, and correlations between sample composition and their geographical origin were identified by multivariate data analysis.

8 May 2018 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
INIoan O. Neaga
Ioan O. Neaga
SHStephanie Hambye
Stephanie Hambye
EBEde Bodoki
Ede Bodoki
CPClaudio Palmieri
Claudio Palmieri
EAEugénie Ansseau
Eugénie Ansseau
BBBertrand Blankert
Bertrand Blankert

15 November 2018 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
INIoan O. Neaga
Ioan O. Neaga
SHStephanie Hambye
Stephanie Hambye
EBEde Bodoki
Ede Bodoki
CPClaudio Palmieri
Claudio Palmieri
Jean Jacques Vanden EyndeJean Jacques Vanden Eynde
Jean Jacques Vanden Eynde
BBBertrand Blankert
Bertrand Blankert
Unfortunately the name of Jean Jacques Vanden Eynde was missing as co-author of this contribution. The correct list of authors is: Ioan O. Neaga, Stephanie Hambye, Ede Bodoki, Claudio Palmieri, Jean...