Pablo Hernandez-Cerdan

Pablo Hernandez-Cerdan

Auto-generated profile, based on publicly available information

Pablo Hernandez-Cerdan

Kitware, Inc. 101 East Weaver Street, Carrboro, NC, USA 25710

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2018 in Biomacromolecules
Verified
Journal Article
Closed access
PHPablo Hernandez-Cerdan
Pablo Hernandez-Cerdan
BMBradley William Mansel
Bradley William Mansel
ALAndrew Leis
Andrew Leis
LLLeif Lundin
Leif Lundin
BWBill Williams
Bill Williams

12 March 2018
Verified
Conference Paper
Closed access
PDF file
BPBeatriz Paniagua
Beatriz Paniagua
HSHina Shah
Hina Shah
PHPablo Hernandez-Cerdan
Pablo Hernandez-Cerdan
FBFrancois Budin
Francois Budin
DCDeepak Chittajallu
Deepak Chittajallu
JVJean-Baptiste Vimort
Jean-Baptiste Vimort
Studies show that cracked teeth are the third most common cause for tooth loss in industrialized countries. If detected early and accurately, patients can retain their teeth for a longer time. Most cracks are not detected early because of the discontinuous symptoms and lack of good diagnostic tools. Currently used imaging modalities like Cone Beam Computed Tomography (CBCT) and intraoral radiography often have low sensitivity and do not show cracks clearly. This paper introduces a novel method that can detect, quantify, and localize cracks automatically in high resolution CBCT (hr-CBCT) scans of teeth using steerable wavelets and learning methods. These initial results were created using hr-CBCT scans of a set of healthy teeth and of teeth with simulated longitudinal cracks. The cracks were simulated using multiple orientations. The crack detection was trained on the most significant wavelet coefficients at each scale using a bagged classifier of Support Vector Machines. Our results show high discriminative specificity and sensitivity of this method. The framework aims to be automatic, reproducible, and open-source. Future work will focus on the clinical validation of the proposed techniques on different types of cracks ex-vivo. We believe that this work will ultimately lead to improved tracking and detection of cracks allowing for longer lasting healthy teeth.

1 January 2010 in Journal of Neurophysiology
Verified
Journal Article
Open access
PDF file
RLRoberto Lagunes-Córdoba
Roberto Lagunes-Córdoba
PHPablo Rogelio Hernández
Pablo Rogelio Hernández
JRJosé Guadalupe Raya
José Guadalupe Raya
EME. J. Muñoz-Martínez
E. J. Muñoz-Martínez
The question of whether skin receptors might help in the perception of muscle contraction and body movement has not been settled. The present study gives direct evidence of skin receptor firing in close coincidence with the contraction of the vaginal and anal sphincters. The distal stump of the sectioned motor pudendal nerve was stimulated. Single shocks induced a wavelike increase in the lumen pressure of the distal vagina and the anal canal, as well as constriction of the vaginal introitus and the anus. The constriction pulls on and moves the surrounding skin, which was initially detected visually. In the present experiments, a thin strain gauge that pressed on the skin surface detected its displacement. Single shocks to the motor nerve induced a wave of skin movement with maximal amplitude at 5 mm from the anus and propagated with decrement beyond 35 mm. The peripheral terminals of the sensory pudendal nerve and the posterior femoral nerve supply the skin that moves. Sensory axons from both nerves fired in response to both tactile stimulation and the skin movement produced by the constriction of the orifices (motor–sensory coupling). In cats with all nerves intact, a single shock to the sensory nerves induced reflex waves of skin movement and lumen pressure (sensory–motor coupling). Both couplings provide evidence for a feedforward action that might help to maintain the female posture during mating and to the perception of muscle contraction.

2 October 2023
Verified
Conference Paper
Closed access
PMPhilipp Mand
Philipp Mand
PHPablo Hernandez
Pablo Hernandez
CPChristian Poivey
Christian Poivey
VGViyas Gupta
Viyas Gupta
The increase of lower class satellite missions and the reduction of space launch costs increase the need for performant and affordable electronics with a short lead time. This leads to the increasing demand for Commercial Off-The-Shelf (COTS) component usage in Space. Especially the selection of DC-DC buck converters is highly important considering their sensitivity to Destructive Single Event Effects which can lead to the loss of the regulated load or even a short on the power bus. In this paper, multiple modern COTS DC-DC buck converter ICs with integrated power MOSEFTs are tested against SEEs and their usability in Space is evaluated. Devices from various manufacturers and with different maximum input voltages were chosen. First promising results were gathered and therefore the derating capability as well as the overall SEE sensitivity is evaluated for these given COTS buck converters in Space. SEE testing showed not only DSEEs but also overvoltage conditions at the load as well as multiple Single Event Functional Interrupts and for some devices Single Event Latch-ups, all of which need consideration depending on their application in Space.

15 March 2019 in Proceedings of SPIE
Verified
Conference Paper
Closed access
PDF file
PHPablo Hernandez-Cerdan
Pablo Hernandez-Cerdan
BPBeatriz Paniagua
Beatriz Paniagua
JPJack Prothero
Jack Prothero
JMJames S. Marron
James S. Marron
ELEric Livingston
Eric Livingston
MMMatthew M. McCormick
Matthew M. McCormick
Computed tomography (CT) images can potentially provide insights into bone structure for diagnosis of disorders and diseases. However, evaluation of trabecular bone structure and whole bone shape is often qualitative or semiquantitative. This limits inter-study comparisons and the ability to detect subtle bone quality variations during early disease onset or in response to new treatments. In this work, we enable quantitative characterization of bone diseases through bone morphometry, texture analysis, and shape analysis methods. The potential of our analysis methods to identify the impact of hemophilia is validated in a mouse femur wound model. In our results, shape localizes and characterizes the formation of spurious bone, and our texture and bone morphometry analysis results provide extra information about the composition of that bone. Some of our one-dimensional (1D) textural features were able to significantly differentiate our injured femurs from our healthy femurs, even with this small sample size demonstrating the potential of the proposed analysis framework. While trabecular bone morphometrics have been a pillar in 3D microCT bone research for decades, the proposed analysis framework augments how we define and understand phenotypical presentation of bone disease. The contributed open source software is exposed to the medical image analysis community through 3D Slicer extensions to ensure both robustness and reproducibility.

15 March 2019
Verified
Conference Paper
Closed access
PDF file
BPBeatriz Paniagua
Beatriz Paniagua
JPJack Prothero
Jack Prothero
JVJean-Baptiste Vimort
Jean-Baptiste Vimort
ARAntonio Carlos O. Ruellas
Antonio Carlos O. Ruellas
JMJames S. Marron
James S. Marron
PHPablo Hernandez-Cerdan
Pablo Hernandez-Cerdan
Temporomandibular Joint (TMJ) Osteoarthritis (OA) is associated with significant pain and disability. It is really hard to diagnose TMJ OA during early stages of the disease. Subchondral bone texture has been observed to change in the TMJ early during TMJ OA progression. We believe that raw probability-distribution matrices describing image texture encode important information that might aid diagnosing TMJ OA. In this paper we present novel statistical methods for High Dimensionality Low Sample Size Data (HDLSSD) to test the discriminatory power of probability-distribution matrices in computed from TMJ OA medical scans. Our results, and comparison with previous results obtained from the summary features obtained from them indicate that probability-distribution matrices are an important piece of information provided by texture analysis methods and should not be down sampled for analysis.