Frédéric Giraud

Frédéric Giraud

Auto-generated profile, based on publicly available information

Frédéric Giraud

University of Lille, Villeneuve d'Ascq, France

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2007 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MBMelisande Biet
Melisande Biet
FGFrederic Giraud
Frederic Giraud
BLBetty Lemaire-Semail
Betty Lemaire-Semail
Most tactile displays currently built rely on pin-based arrays. However, this kind of tactile device is not always appropriate when we need to give the illusion of finely textured surfaces. In this paper, we describe the squeeze film effect between a plate and a finger, and we use this effect to design an ultrasonic tactile plate. The plate is actuated by piezoelectric ceramics. Ultrasonic vibrations are thus produced and are capable of generating the squeeze film effect. This enables us to simulate variable friction on the surface of the plate. In order to identify the squeeze film phenomenon, this study considers the case where a finger, with a planar bottom surface and with epidermal ridges, is placed on a rapidly vibrating plate. The overpressure is calculated and the result enables us to assess the relative coefficient of friction as a function of the vibration amplitude of the plate. Based on this principle, and using both analytic and FE method studies, and given ergonomic and stimulation (squeeze film) requirements, we show that it is possible to design a tactile plate which is capable of giving programmable tactile sensations. We conclude by comparing the results obtained from our simulations with experimental results.

1 March 2008
Verified
Conference Paper
Closed access
MBMelisande Biet
Melisande Biet
GCGery Casiez
Gery Casiez
FGFrederic Giraud
Frederic Giraud
BLBetty Lemaire-Semail
Betty Lemaire-Semail
In this paper, we investigate the use of friction based tactile displays for the simulation of finely textured surfaces, as such displays offer a promising way for the development of devices with co-located vision and tactile feedback. The resolution of the textures rendered with such devices and their matching to real textures have never been investigated. The paper first contributes to the evaluation of the texture resolution of friction based tactile displays. In a controlled experiment, we investigate the differential thresholds for square gratings simulated with a friction based tactile device by dynamic touch. Then we compare them to the differential thresholds of real square wave gratings. We found that the Weber fraction remains constant across the different spatial period at 9%, which is close to the Weber fraction found for corresponding real square gratings. This study inclines us to conclude that friction based tactile displays offers a realistic alternative to pin based arrays and can be used for co-located vision and tactile rendering. From the results of the experiment, we also give the design guidelines to improve the perception of textures on friction based tactile displays.

18 December 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SGSofiane Ghenna
Sofiane Ghenna
FGFrederic Giraud
Frederic Giraud
CGChristophe Giraud-Audine
Christophe Giraud-Audine
MAMichel Amberg
Michel Amberg
This paper presents the implementation of a novel vibration amplitude control and resonant frequency tracking for piezoelectric transducers (PTs) and ultrasonic motors (USMs). It is based on a generalization of the vector control method to the PT and the USM, which is explained in the first part. We show that two independent controllers with a similar structure are required: one tracks the resonant frequency and the second controls the amplitude. We then present the implementation into a low-cost digital signal processing controller with a sampling period of 200 μs. Experimental results on a Langevin transducer achieved a time response of 20 ms approximately, and the generality of the method is further demonstrated on a 2-D tactile stimulator at the end of this paper.

1 March 2012
Verified
Conference Paper
Closed access
FGFrederic Giraud
Frederic Giraud
MAMichel Amberg
Michel Amberg
BLBetty Lemaire-Semail
Betty Lemaire-Semail
GCGery Casiez
Gery Casiez
This paper presents the design of a transparent tactile stimulator, based on the friction reduction between the fingertip and the active surface. With such a design, the ratio between the useful area (i.e. the active display and the tactile area) and the device face is equal to 0.7, while the touched area's size is 93mm×65mm. Key design procedure is given, and experimental results are presented.

1 July 2013 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
FGFrédéric Giraud
Frédéric Giraud
MAMichel Amberg
Michel Amberg
BLBetty Lemaire-Semail
Betty Lemaire-Semail

23 July 2007 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
FGFrederic Giraud
Frederic Giraud
BLBetty Lemaire-Semail
Betty Lemaire-Semail
JAJulien Aragones
Julien Aragones
JRJacques P. Robineau
Jacques P. Robineau
JAJean-Thierry Audren
Jean-Thierry Audren
In this paper, precise position control of a traveling-wave ultrasonic motor is achieved, avoiding the traditional drawbacks attributable to nonlinear torque generation, which are overshoot or slow response time. For that purpose, a behavior model control is proposed and presented. With this control law, a quick and precise response is obtained. In this paper, we present a position-control scheme of an inertial load. The guideline used for this control was a rotation of 90 in a response time of about 200 ms with a position error of 0.6 mrad, targeting a typical application for avionics. In this paper, a Shinsei USR30 is used, but the method can be applied to other ultrasonic motors.