One of the stages in development and implementation of the quality system in medical laboratories is to conduct the validation works. The main objects of these works are the methods by which measurements of various parameters inthe laboratory are carried out.Aim. To study the quality assurance aspects in the Laboratory of the Clinical Diagnostics of the Clinical and Diagnostic Center at the National University of Pharmacy (NPhU) by carrying out validation procedures to assess the intra-laboratory reproducibility of biochemical methods.Materials and methods. The objects of the study were standardized biochemical methods for determining the levels of gamma-glutamyltransferase (GGT) and alkaline phosphatase in the samples of biological fluids. The “Chemical control.A reagent kit” produced by High Technology, Inc. (USA) with the known concentration of analytes was selected as a control serum. The measurements were carried out using the Express Plus automatic biochemical analyzer manufactured by Bayer (Germany). When processing the results of the research the indicators of descriptive statistics were used, and statistical estimates were made.Results. The assessment of intralaboratory convergence and reproducibility of the methods for determining the concentration of GGT and alkaline phosphatase by the photometric method when working on the Express Plus biochemicalanalyzer carried out by two operators-laboratory technicians of the same qualification indicates the absence of gross errors in the analyzer operation and statistically significant differences in the measurements. The assessment of themethod correctness using the standard sample has proven that the systematic error is insignificant (according to the criterion of acceptability specified). Thus, these methods provide the correctness of measurements within the laboratory. The increased uncertainty calculated as a metrological assessment of acceptability has shown that the values of the GGT and alkaline phosphatase levels obtained can be considered accurate and reliable. Conclusions. The validation of the methods for determination of GGT and alkaline phosphatase in the human blood by the photometric method has proven that these methods have performance characteristics corresponding to the regulated ones, satisfy the criteria specified, and the parameters measured with them correspond to the proper ones.
Approaches to the implementation of the quality system in accordance with ISO 15189:2015 in the Laboratory of Clinical Diagnostics of the Clinical and Diagnostic Center at the National University of Pharmacy on the example of methods for determining the l
The main principles of creating a quality system in modern laboratory diagnostics are: standardization of laboratory processes by developing standard operating procedures; general quality management of laboratory research based on the development and implementation of the requirements of international standards (according to ISO 15189: 2015 "Medical laboratories. Basic requirements for quality and competence"); quality control of all stages of the laboratory process through the implementation of the validation procedure. Aim. To develop a methodology for conducting validation procedures to assess the suitability of a biochemical method for determining the level of total cholesterol in biological fluids in the Clinical Diagnostic Laboratory of the Clinical Diagnostic Center of the NUPh. Materials and methods. The object of the study was a standardized method for determining the concentration of total cholesterol. The method was validated using the “Cholesterol Reagent Set” test kit and the standard sample “Chemical control. Reagent kit. Level 1 ", manufactured by High Technology, Inc. (USA) with known concentration. The measurements were carried out on an Express Plus automatic biochemical analyzer manufactured by Bayer Corporation, Germany. When processing the research results, descriptive statistics were used and a number of statistical evaluations were carried out. Results. A protocol and a validation report were developed at the Clinical Diagnostic Laboratory of the CDC NUPh to assess the suitability of the method for determining the concentration of cholesterol in biological fluids by the photometric enzymatic method on an automatic biochemical analyzer Express Plus (using reagents and control material manufactured by High Technology, Inc., USA). The validation characteristics of the method were determined: repeatability and reproducibility, correctness and uncertainty of measurements. Evaluation of the internal laboratory repeatability and reproducibility of this technique indicates the absence of gross errors in the operation of the instrument and statistically important differences in measurements. The assessment of the correctness of the method (carried out using the control material) proved that the systematic error is not significant (according to a given acceptance criterion). The expanded uncertainty calculation showed that the obtained values of the total cholesterol level can be considered accurate and reliable. Conclusions. Validation of the method for determining total cholesterol in human blood by the photometric enzymatic method has proven that this method has performance characteristics that correspond to the regulated ones, meets the established criteria, and the parameters measured with it correspond to the proper ones. Key words: validation, determination method, total cholesterol, repeatability and reproducibility, correctness and uncertainty of measurements
The scientific and practical substantiation of the therapeutic drug monitoring procedure: validation of the analytical method of valproic acid measurement