Peilun Li

Peilun Li

Auto-generated profile, based on publicly available information

Peilun Li

Department of Biomedical Engineering Zhejiang University Hangzhou China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Microvascular Research
Verified
Journal Article
Closed access
QPQing Pan
Qing Pan
WFWeida Feng
Weida Feng
RWRuofan Wang
Ruofan Wang
ATArata Tabuchi
Arata Tabuchi
PLPeilun Li
Peilun Li
GNGangmin Ning
Gangmin Ning

28 July 2022 in Frontiers in Psychology
Verified
Journal Article
Open access
JCJunjin Chen
Junjin Chen
SZShuaishuai Zhai
Shuaishuai Zhai
ZXZenghui Xi
Zenghui Xi
PLPeilun Li
Peilun Li
SZShuolin Zhang
Shuolin Zhang
Purpose: Spectators have a significant impact on match performances in soccer, but to what extent crowd support contributes to the technical and physical performances remains unclear. This study aimed to (1) investigate the differences in terms of technical and physical performances with and without spectators; and (2) identify the key factors differentiating between win and loss when playing with and without the presence of an audience.Methods: Our study examined 794 performance records from 397 matches during the 2019–2020 seasons in the Chinese Soccer Super League. The least absolute shrinkage and selection operator (LASSO)-logistic regression was utilized to select significant predictors. Using an independent t-test and the Mann–Whitney non-parametric test explores the difference between matches with and without spectators. Key factors between win and loss were explored using univariate and multivariate logistic regression analyses.Results: Our study found that cross (p < 0.01, ES = −0.24), shots (p < 0.001, ES = −0.25), and shot accuracy (p < 0.05, ES = −0.18) displayed decreasing trends whereas sprint distances (p < 0.05, ES = 0.16) presented an increasing trend without spectators comparing with the crowd support. Moreover, the above three technical variables were the main factors differentiating between wins and losses. Similarly, team and opponent quality remained important potential factors affecting the match outcome.Conclusion: Match outcome or team performance is determined by a myriad of factors, but there are clear differences in technical and physical performances between matches with and without the presence of an audience. Similarly, our study provides a better explanation for the impact of crowd support on match performances whereby coaches can deploy players and adjust match strategies for ultimate success.

12 December 2021 in Microcirculation
Verified
Journal Article
Closed access
PDF file
PLPeilun Li
Peilun Li
QPQing Pan
Qing Pan
SJSheng Jiang
Sheng Jiang
WKWolfgang M. Kuebler
Wolfgang M. Kuebler
APAxel R. Pries
Axel R. Pries
GNGangmin Ning
Gangmin Ning

1 May 2024 in Microcirculation
Verified
Journal Article
Closed access
QPQing Pan
Qing Pan
HSHuanghui Shen
Huanghui Shen
PLPeilun Li
Peilun Li
BLBiyun Lai
Biyun Lai
AJAkang Jiang
Akang Jiang
GNGangmin Ning
Gangmin Ning

1 September 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MZMin Zhang
Min Zhang
YWYanmei Wang
Yanmei Wang
PLPeilun Li
Peilun Li
YZYadan Zhang
Yadan Zhang
Min XiangMin Xiang
Min Xiang
Magnetocardiography (MCG) source localisation plays a key role in estimating cardiac electrical activity and identifying abnormal activity locations for disease diagnosis. To improve estimation accuracy in clinical applications, evaluating the performance of MCG sensor arrays is crucial for selecting optimal configurations. Such evaluations have traditionally been conducted through various metrics. However, these metrics depend on specific estimation algorithms and fail to directly reflect how the sensor array influences the variance of parameter estimation. Furthermore, the diversity of estimation algorithms hinders the establishment of uniform assessment criteria. To overcome these challenges, we present an evaluation method for MCG arrays focused on minimising the variance in source parameter estimation. The method leverages the Cramér-Rao Bound (CRB), a theoretical limit on the variance of unbiased estimators and independent of the employed algorithm. Aided by the boundary element method, we derive the CRB framework for estimating cardiac source parameters using MCG data and quantify the effect of adding sensors on the CRB. In addition, we utilise the CRB to evaluate the performance of MCG arrays measuring different magnetic field components, quantifying the advantages of three-dimensional (3D) vector field measurements for source estimation. Compared to conventional radial measurements, 3D vector measurements reduce the equivalent uncertainty radius by more than 25.62%. Finally, we apply the approach to optimise sensor arrangements when the number of sensors is limited. Overall, our results show that the CRB effectively evaluates MCG arrays across diverse configurations, making it applicable to various clinical and engineering applications.

20 March 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MZMin Zhang
Min Zhang
YWYanmei Wang
Yanmei Wang
PLPeilun Li
Peilun Li
YZYadan Zhang
Yadan Zhang
YCYangyang Cui
Yangyang Cui
Min XiangMin Xiang
Min Xiang
Magnetocardiography (MCG) source imaging allows high-precision three-dimensional localisation of regions with abnormal cardiac activity, playing a crucial role in disease diagnosis. In practical measurements, however, four key types of error in sensor arrays, i.e., crosstalk, gain error, angular error, and position error, can distort magnetic signals or the lead field matrix, thereby compromising imaging performance. To date, their impact on MCG source imaging has not been systematically assessed. In this study, we establish an evaluation framework and systematically investigate the effects of these errors for the first time. A comprehensive evaluation is conducted across three key aspects: reconstruction accuracy, spatial resolution, and the localisation accuracy of correlated sources. Our results indicate that all four error types degrade imaging performance to varying degrees. The detrimental influence of errors on reconstruction accuracy and spatial resolution becomes more severe as the signal-to-noise ratio increases. For the localisation of correlated sources, increases in the number of sources and the inter-source coupling strength further exacerbate the interference caused by array errors. Based on the configuration in this work, we derive conservative safe operating limits: crosstalk <1%, gain error <3%, angular error <1°, and position error <2 mm. Therefore, precise calibration of sensor parameters before MCG measurements is essential to ensure imaging performance. This study highlights that systematically evaluating array errors is critical for designing calibration strategies and supporting the clinical application of MCG systems.