Mika Okahara

Mika Okahara

Auto-generated profile, based on publicly available information

Mika Okahara

All authors: Department of Radiology, Oita University Faculty of Medicine, Hasama-machi 1-1, Oita 879-5593 Japan

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2002 in Stroke
Verified
Journal Article
Closed access
MOMika Okahara
Mika Okahara
HKHiro Kiyosue
Hiro Kiyosue
MYMasanori Yamashita
Masanori Yamashita
HNHirohumi Nagatomi
Hirohumi Nagatomi
HHHiroyuki Hata
Hiroyuki Hata
HMHiromu Mori
Hiromu Mori
Background and Purpose — We investigated the sensitivity of 3D–time-of flight (3D-TOF) magnetic resonance angiography (MRA) in the detection of cerebral aneurysms with the use of 3D digital subtraction angiography as the gold standard. We also evaluated the effects of location and number of aneurysms (and experience of the reader) on the sensitivity. Methods — 3D-TOF MRA was performed in 82 patients with 133 cerebral aneurysms. Each patient underwent rotational angiography. Three-dimensional reconstructed images were obtained from data of the rotational angiography (as the gold standard). A blind study with 4 readers of different experiences was performed to evaluate the diagnostic accuracy of 3D-TOF MRA for cerebral aneurysms. Results — One hundred five (79%) of all 133 aneurysms were detected with MRA by a neuroradiologist, 100 (75%) were detected by an experienced neurosurgeon, 84 (63%) were detected by a general radiologist, and 80 (60%) were detected by a resident neuroradiologist. For each reader, the detectability was lower for small aneurysms (<3 mm in maximum diameter) and/or for those located at the internal carotid artery and anterior cerebral artery. False-positive aneurysms were 29 for the neuroradiologist, 19 for the neurosurgeon, 31 for the general radiologist, and 30 for the resident neuroradiologist; most of the aneurysms were at the internal carotid artery. Causes of the false-positive and false-negative results included complex flow in a tortuous artery and susceptibility artifacts. Conclusions — Although MRA is useful in the diagnosis of cerebral aneurysms, sufficient experience and careful attention are necessary for accurate diagnosis of aneurysms located at the internal carotid and anterior cerebral arteries.

21 March 2002 in European Radiology
Verified
Journal Article
Closed access
PDF file
MOMika Okahara
Mika Okahara
HKHiro Kiyosue
Hiro Kiyosue
HMHiromu Mori
Hiromu Mori
STShuichi Tanoue
Shuichi Tanoue
MSMichihumi Sainou
Michihumi Sainou
HNHirohumi Nagatomi
Hirohumi Nagatomi

10 October 2003 in European Radiology
Verified
Journal Article
Closed access
PDF file
MOMika Okahara
Mika Okahara
HKHiro Kiyosue
Hiro Kiyosue
YHYuko Hori
Yuko Hori
AMAkira Matsumoto
Akira Matsumoto
HMHiromu Mori
Hiromu Mori
SYShigeo Yokoyama
Shigeo Yokoyama

21 April 2004 in European Radiology
Verified
Journal Article
Closed access
PDF file
MOMika Okahara
Mika Okahara
HKHiro Kiyosue
Hiro Kiyosue
YHYuzo Hori
Yuzo Hori
MYMasanori Yamashita
Masanori Yamashita
HNHirofumi Nagatomi
Hirofumi Nagatomi
HMHiromu Mori
Hiromu Mori

1 April 2002
Verified
Journal Article
Closed access
HKHiro Kiyosue
Hiro Kiyosue
STShuichi Tanoue
Shuichi Tanoue
MOMika Okahara
Mika Okahara
MYMasanori Yamashita
Masanori Yamashita
HNHirohumi Nagatomi
Hirohumi Nagatomi
HMHiromu Mori
Hiromu Mori

1 August 2002
Verified
Journal Article
Closed access
HKHiro Kiyosue
Hiro Kiyosue
STShuichi Tanoue
Shuichi Tanoue
MOMika Okahara
Mika Okahara
YHYuzo Hori
Yuzo Hori
TNTakaharu Nakamura
Takaharu Nakamura
HMHiromu Mori
Hiromu Mori