Michael Zawaneh

Michael Zawaneh

Auto-generated profile, based on publicly available information

Michael Zawaneh

From the Department of Radiology (M.G.) and Division of Cardiology (J.I., R.T.), Banner University Medical Center Tucson, Tucson, Ariz; Division of Clinical Data Analytics, University of Arizona College of Medicine Phoenix, Phoenix, Ariz (P.R.); and Department of Radiology (S.U., B.T., M.F.M.) and Division of Cardiology (W.S., J.P.W., M.Z., S.U., B.T., M.F.M.), Banner University Medical Center Phoenix, 1111 E McDowell Rd, Phoenix, AZ 85006

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
RYRonghui Yu
Ronghui Yu
NLNian Liu
Nian Liu
BYBinquan You
Binquan You
HWHaixiong Wang
Haixiong Wang
YRYanfei Ruan
Yanfei Ruan
RBRong Bai
Rong Bai
Pericardiocentesis is usually completed under fluoroscopy. The electroanatomic mapping (EAM) system allows visualizing puncture needle tip (NT) while displaying the electrogram recorded from NT, making it possible to obtain epicardial access (EA) independent of fluoroscopy. This study was designed to establish and validate a technique by which EA is obtained under guidance of three-dimensional (3D) EAM combined with NT electrogram. 3D shell of the heart was generated, and the NT was made trackable in the EAM system. Unipolar NT electrogram was continuously monitored. Penetration into pericardial sac was determined by an increase in NT potential amplitude and an injury current. A long guidewire of which the tip was also visible in the EAM system was advanced to confirm EA. Epicardial access was successfully obtained without complication in 13 pigs and 22 patients. In the animals, NT potential amplitude was 3.2 ± 1.0 mV when it was located in mediastinum, 5.2 ± 1.6 mV when in contact with fibrous pericardium, and 9.8 ± 2.8 mV after penetrating into pericardial sac (all P ≤ 0.001). In human subjects, it measured 1.54 ± 0.40 mV, 3.61 ± 1.08 mV, and 7.15 ± 2.88 mV, respectively (all P < 0.001). Fluoroscopy time decreased in every 4–5 cases (64 ± 15, 23 ± 17, and 0 s for animals 1–4, 5–8, 9–13, respectively, P = 0.01; 44 ± 23, 31 ± 18, 4±7 s for patients 1–7, 8–14, 15–22, respectively, P < 0.001). In five pigs and seven patients, EA was obtained without X-ray exposure. By tracking NT in the 3D EAM system and continuously monitoring the NT electrogram, it is feasible and safe to obtain EA with minimum or no fluoroscopic guidance. Demonstration of connection of pericardiocentesis needle to the EAM system and recording of needle tip electrogram. (A–C) The proximal end of a modified Tuohy needle was connected to the EAM system via a jumper wire (J), the body of needle was covered by outer sheath (N + S) except for the tip that remained electrically conductive. The needle was inserted underneath the subxiphoid at an angle of 45–60° to the body surface and was kept at a direction towards to the front one-half of the inferior wall of the right ventricle. (D) A closer view at LAO 45° of the needle tip (NT) and its relative location to the heart. The red circles represented the needle tip location when it was in the mediastinum over the diaphragm (MD), in contact with fibrotic epicardium (FP), and penetrated into pericardial sac (PS). The typical needle tip unipolar electrogram (N1) at these three locations were shown in panel F. (E) In the EAM system, the needle was detected as a bipolar catheter (yellow arrow). It was real-timely tracked and displayed with pre-acquired 3D shells of LV and RV in different projections (left: AP view; right: LAO 45° view). (F) The dominant component of the needle electrogram was the electrical activity from ventricles, namely Ned potential, corresponding to the QRS complex on surface ECG. Lower row—small Ned potential when NT in the mediastinal; middle row—larger Ned potential with small injury current (white arrow) when NT in contact with fibrotic pericardium. A PVC (blue arrow) indicated that the needle tip has been in contact with the heart; upper row—giant Ned potential with significant injury current (red arrow) when NT penetrated into pericardial sac. FP, fibrous pericardium; MD, mediastinum; PS, pericardial space; Myo, myocardium; Ned, the dominant potential on needle electrogram; J, jumper wire; N + S, needle with outer sheath; other abbreviations as Figures 1–6.

1 June 2024 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Closed access
MGMark Greenhill
Mark Greenhill
PRPooja Rangan
Pooja Rangan
WSWilber Su
Wilber Su
JWJ. Peter Weiss
J. Peter Weiss
MZMichael Zawaneh
Michael Zawaneh
MMMichael F. Morris
Michael F. Morris
Purpose To examine the clinical effect of lead length and lead orientation in patients with cardiac implantable electronic devices (CIEDs) and lead fragments or abandoned leads undergoing 1.5-T MRI. Materials and Methods This Health Insurance Portability and Accountability Act-compliant retrospective study included patients with CIEDs and abandoned leads or lead fragments undergoing 1.5-T MRI from March 2014 through July 2020. CIED settings before and after MRI were reviewed, with clinically significant variations defined as a composite of the change in capture threshold of at least 50%, in sensing of at least 40%, or in lead impedance of at least 30% between before MRI and after MRI interrogation. Adverse clinical events were assessed at MRI and up to 30 days after. Univariable and multivariable analysis was performed. Results Eighty patients with 126 abandoned CIED leads or lead fragments underwent 107 1.5-T MRI examinations. Sixty-seven patients (median age, 74 years; IQR, 66-78 years; 44 male patients, 23 female patients) had abandoned leads, and 13 (median age, 66 years; IQR, 52-74 years; nine male patients, four female patients) had lead fragments. There were no reported deaths, clinically significant arrhythmias, or adverse clinical events within 30 days of MRI. Three patients with abandoned leads had a significant change in the composite of capture threshold, sensing, or lead impedance. In a multivariable generalized estimating equation analysis, lead orientation, lead length, MRI type, and MRI duration were not associated with a significant change in the composite outcome. Conclusion Use of 1.5-T MRI in patients with abandoned CIED leads or lead fragments of varying length and orientation was not associated with adverse clinical events. Keywords: Cardiac Assist Devices, MRI, Cardiac Implantable Electronic Device Supplemental material is available for this article. © RSNA, 2024.