Caglar Ozturk

Caglar Ozturk

Auto-generated profile, based on publicly available information

Caglar Ozturk

Massachusetts Institute of Technology

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2022 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
LRLuca Rosalia
Luca Rosalia
COCaglar Ozturk
Caglar Ozturk
JCJaume Coll-Font
Jaume Coll-Font
YFYiling Fan
Yiling Fan
YNYasufumi Nagata
Yasufumi Nagata
CNChristopher T. Nguyen
Christopher T. Nguyen

22 February 2023 in Science Robotics
Verified
Journal Article
Closed access
LRLuca Rosalia
Luca Rosalia
COCaglar Ozturk
Caglar Ozturk
Debkalpa GoswamiDebkalpa Goswami
Debkalpa Goswami
JBJean Bonnemain
Jean Bonnemain
SWSophie X. Wang
Sophie X. Wang
EREllen Roche
Ellen Roche
Aortic stenosis (AS) affects about 1.5 million people in the United States and is associated with a 5-year survival rate of 20% if untreated. In these patients, aortic valve replacement is performed to restore adequate hemodynamics and alleviate symptoms. The development of next-generation prosthetic aortic valves seeks to provide enhanced hemodynamic performance, durability, and long-term safety, emphasizing the need for high-fidelity testing platforms for these devices. We propose a soft robotic model that recapitulates patient-specific hemodynamics of AS and secondary ventricular remodeling which we validated against clinical data. The model leverages 3D-printed replicas of each patient’s cardiac anatomy and patient-specific soft robotic sleeves to recreate the patients’ hemodynamics. An aortic sleeve allows mimicry of AS lesions due to degenerative or congenital disease, whereas a left ventricular sleeve recapitulates loss of ventricular compliance and diastolic dysfunction (DD) associated with AS. Through a combination of echocardiographic and catheterization techniques, this system is shown to recreate clinical metrics of AS with greater controllability compared with methods based on image-guided aortic root reconstruction and parameters of cardiac function that rigid systems fail to mimic physiologically. Last, we leverage this model to evaluate the hemodynamic benefit of transcatheter aortic valves in a subset of patients with diverse anatomies, etiologies, and disease states. Through the development of a high-fidelity model of AS and DD, this work demonstrates the use of soft robotics to recreate cardiovascular disease, with potential applications in device development, procedural planning, and outcome prediction in industrial and clinical settings.

8 December 2023 in Nature Cardiovascular Research
Verified
Journal Article
Open access
PDF file
MSManisha Singh
Manisha Singh
JBJean Bonnemain
Jean Bonnemain
COCaglar Ozturk
Caglar Ozturk
BABrian Ayers
Brian Ayers
MSMossab Y. Saeed
Mossab Y. Saeed
EREllen Roche
Ellen Roche
The increasing recognition of the right ventricle (RV) necessitates the development of RV-focused interventions, devices and testbeds. In this study, we developed a soft robotic model of the right heart that accurately mimics RV biomechanics and hemodynamics, including free wall, septal and valve motion. This model uses a biohybrid approach, combining a chemically treated endocardial scaffold with a soft robotic synthetic myocardium. When connected to a circulatory flow loop, the robotic right ventricle (RRV) replicates real-time hemodynamic changes in healthy and pathological conditions, including volume overload, RV systolic failure and pressure overload. The RRV also mimics clinical markers of RV dysfunction and is validated using an in vivo porcine model. Additionally, the RRV recreates chordae tension, simulating papillary muscle motion, and shows the potential for tricuspid valve repair and replacement in vitro. This work aims to provide a platform for developing tools for research and treatment for RV pathophysiology.

11 August 2022 in Advanced Functional Materials
Verified
Journal Article
Open access
CPClara Park
Clara Park
COCaglar Ozturk
Caglar Ozturk
EREllen Roche
Ellen Roche
Soft robotic devices containing multiple actuating elements have successfully recapitulated complex biological motion, leading to their utility in biomedical applications. However, there are inherent nonlinear mechanics associated with soft composite materials where soft actuators are embedded in elastomeric matrices. Predicting their overall behavior prior to fabrication and subsequent experimental characterization can therefore present a hurdle in the design process and in efficiently satisfying functional requirements and specifications. In this work, a computational design framework for optimizing the motion and function of biomimetic soft robotic composites is demonstrated by conducting a design case study of soft robotic cardiac muscle (myocardium) with a particular focus on applications including replicating and assisting cardiac motion and function. A finite element model of a soft robotic myocardium is built, in which actuators are prescribed with anisotropic strain to simulate local deformation, and various design parameters are investigated by evaluating the performance of each configuration in terms of ventricular twist, volumetric output, and pressure generation. Then, an optimized design is proposed that recapitulates the physiological motion and hemodynamics of the heart, and its thrombogenicity is further explored using a fluid‐structure interaction model. This framework has broader utility in predicting the performance of other soft robotic embedded composites.

12 December 2024 in Advanced Science
Verified
Journal Article
Open access
COCaglar Ozturk
Caglar Ozturk
DPDaniel H. Pak
Daniel H. Pak
LRLuca Rosalia
Luca Rosalia
DGDebkalpa Goswami
Debkalpa Goswami
MRMary E. Robakowski
Mary E. Robakowski
EREllen Roche
Ellen Roche
Aortic stenosis (AS) is the most common valvular heart disease in developed countries. High‐fidelity preclinical models can improve AS management by enabling therapeutic innovation, early diagnosis, and tailored treatment planning. However, their use is currently limited by complex workflows necessitating lengthy expert‐driven manual operations. Here, we propose an AI‐powered computational framework for accelerated and democratized patient‐specific modeling of AS hemodynamics from computed tomography (CT). First, we demonstrate that the automated meshing algorithms can generate task‐ready geometries for both computational and benchtop simulations with higher accuracy and 100 times faster than existing approaches. Then, we show that the approach can be integrated with fluid‐structure interaction and soft robotics models to accurately recapitulate a broad spectrum of clinical hemodynamic measurements of diverse AS patients. The efficiency and reliability of these algorithms make them an ideal complementary tool for personalized high‐fidelity modeling of AS biomechanics, hemodynamics, and treatment planning.

12 June 2024 in Science Robotics
Verified
Journal Article
Closed access
LRLuca Rosalia
Luca Rosalia
SWSophie X. Wang
Sophie X. Wang
COCaglar Ozturk
Caglar Ozturk
WHWei Huang
Wei Huang
JBJean Bonnemain
Jean Bonnemain
EREllen Roche
Ellen Roche
Our understanding of cardiac remodeling processes due to left ventricular pressure overload derives largely from animal models of aortic banding. However, these studies fail to enable control over both disease progression and reversal, hindering their clinical relevance. Here, we describe a method for progressive and reversible aortic banding based on an implantable expandable actuator that can be finely tuned to modulate aortic banding and debanding in a rat model. Through catheterization, imaging, and histologic studies, we demonstrate that our platform can recapitulate the hemodynamic and structural changes associated with pressure overload in a controllable manner. We leveraged soft robotics to enable noninvasive aortic debanding, demonstrating that these changes can be partly reversed because of cessation of the biomechanical stimulus. By recapitulating longitudinal disease progression and reversibility, this animal model could elucidate fundamental mechanisms of cardiac remodeling and optimize timing of intervention for pressure overload.