Adrian F. Howansky

Adrian F. Howansky

Auto-generated profile, based on publicly available information

Adrian F. Howansky

State University of New York at Stony Brook, Department of Radiology, Stony Brook, New York, United States

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2019 in Medical Physics
Verified
Journal Article
Closed access
PDF file
AHAdrian Howansky
Adrian Howansky
AMAnastasiia Mishchenko
Anastasiia Mishchenko
ALA. R. Lubinsky
A. R. Lubinsky
WZWei Zhao
Wei Zhao

9 July 2019 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
ALAnthony R. Lubinsky
Anthony R. Lubinsky
AHAdrian F. Howansky
Adrian F. Howansky
HZHao Zheng
Hao Zheng
WZWei Zhao
Wei Zhao
<!-- *** Custom HTML *** --> Recent advances in thin film transistor array technology have enabled the possibility of “back-irradiated” (BI) indirect active-matrix flat-panel imagers (AMFPIs), in which x-rays first expose the scintillator through the optical sensor, and “dual-screen” AMFPIs, in which two scintillating screens are sandwiched around a bidirectional active matrix. We developed a theoretical treatment of such detectors. The theory is used to investigate possible imaging performance improvements over conventional “front-irradiation” (FI) AMFPIs, where the active matrix is opposite the x-ray entrance surface. Simple expressions for the modulation transfer function, normalized noise power spectrum, Swank factor (As), Lubberts function L ( f ) , and spatial frequency-dependent detective quantum efficiency DQE ( f ) are derived and used to compute these quantities for a variety of FI, BI, and dual-screen detector configurations. DQE ( f ) is used as the figure of merit for optimizing and comparing the performance of the various configurations. Large performance improvements over FI single-screen systems are found possible with BI. Further improvements are found possible with dual-screen configurations. The ratio of the thicknesses of the two screens that optimizes DQE is generally asymmetric, with the thinner screen facing the incident flux. The optimum ratio depends on the x-ray attenuation length in the screen.

11 August 2020 in Journal of the American Ceramic Society
Verified
Journal Article
Closed access
PDF file
Russell LeonardRussell Leonard
Russell Leonard
DBDanielle T. Berkowitz
Danielle T. Berkowitz
ATAustin Thomas
Austin Thomas
AHAdrian Howansky
Adrian Howansky
ALAnthony R. Lubinsky
Anthony R. Lubinsky
Jacqueline A JohnsonJacqueline A Johnson
Jacqueline A Johnson

1 January 2024 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
COCorey Orlik
Corey Orlik
SLSébastien Léveillé
Sébastien Léveillé
SASalman M. Arnab
Salman M. Arnab
AHAdrian F. Howansky
Adrian F. Howansky
JSJann Stavro
Jann Stavro
WZWei Zhao
Wei Zhao
PurposeActive matrix flat panel imagers (AMFPIs) with thin-film transistor arrays experience image quality degradation by electronic noise in low-dose radiography and fluoroscopy. One potential solution is to overcome electronic noise using avalanche gain in an amorphous selenium (a-Se) (HARP) photoconductor in indirect AMFPI. In this work, we aim to improve temporal performance of HARP using a novel composite hole blocking layer (HBL) structure and increase optical quantum efficiency (OQE) to CsI:Tl scintillators by tellurium (Te) doping.ApproachTwo different HARP structures were fabricated: Composite HBL samples and Te-doped samples. Dark current and optical sensitivity measurements were performed on the composite HBL samples to evaluate avalanche gain and temporal performance. The OQE and temporal performance of the Te-doped samples were characterized by optical sensitivity measurements. A charge transport model was used to investigate the hole mobility and lifetime of the Te-doped samples in combination with time-of-flight measurements.ResultsThe composite HBL has excellent temporal performance, with ghosting below 3% at 10 mR equivalent exposure. Furthermore, the composite HBL samples have dark current <10−10 A/cm2 and achieved an avalanche gain of 16. Te-doped samples increased OQE from 0.018 to 0.43 for 532 nm light. The addition of Te resulted in 2.1% first-frame lag, attributed to hole trapping within the layer.ConclusionsThe composite HBL and Te-doping can be utilized to improve upon the limitations of previously developed indirect HARP imagers, showing excellent temporal performance and increased OQE, respectively.

12 May 2020 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
SDScott Dow
Scott Dow
AHAdrian F. Howansky
Adrian F. Howansky
ALAnthony R. Lubinsky
Anthony R. Lubinsky
WZWei Zhao
Wei Zhao
Purpose: Monte Carlo simulations were used to evaluate the imaging properties of a composite direct–indirect active matrix flat-panel imager (AMFPI) with potentially more favorable tradeoffs between x-ray quantum efficiency and spatial resolution than direct or indirect AMFPIs alone. This configuration, referred to as a hybrid AMFPI, comprises a scintillator that is optically coupled to an a-Se direct AMFPI through a transparent electrode and hole blocking layer, such that a-Se acts as both a direct x-ray converter and an optical sensor. Approach: GEANT4 was used to simulate x-ray energy deposition, optical transport, and charge signal generation processes in various hybrid AMPFI configurations under RQA5 and RQA9 x-ray beam conditions. The Fujita–Lubberts–Swank method was used to quantify the impact of irradiation geometry, x-ray converter thicknesses, conversion gain of each layer, and x-ray cross talk between layers on detective quantum efficiency (DQE). Results: Each hybrid configuration had a greater DQE than its direct AMFPI layer alone. The DQE improvement was largest at low spatial frequencies in both front- and back-irradiation (BI) geometries due to increased x-ray quantum efficiency provided by the scintillator. DQE improvements persisted at higher frequencies in BI geometry due to preferential x-ray absorption in a-Se. Matching the x-ray-to-charge conversion gains of a hybrid AMFPI’s direct and indirect detection layers affects its Swank factor and, thus, DQE(0). X-ray cross talk has a negligible impact on the DQE ( f ) of hybrid AMFPIs with sufficiently high optical quantum efficiency. Conclusion: An optimized hybrid AMFPI can achieve greater DQE performance than current direct or indirect AMFPIs.

16 March 2020
Verified
Conference Paper
Closed access
PDF file
AHAdrian F. Howansky
Adrian F. Howansky
AMAnastasiia Mishchenko
Anastasiia Mishchenko
SLSébastien Léveillé
Sébastien Léveillé
SDScott Dow
Scott Dow
JSJann Stavro
Jann Stavro
WZWei Zhao
Wei Zhao
Direct active matrix flat panel imagers (AMFPIs) using amorphous selenium (a-Se) offer high intrinsic spatial resolution but have limited x-ray quantum efficiency at general radiographic energies due to selenium’s low atomic number. Conversely, indirect AMFPIs using inorganic scintillators typically have superior x-ray quantum efficiency at these energies, but inferior spatial resolution and increased noise due to optical effects in the scintillator. These inherent limitations motivate alternative AMFPI designs to further improve detector xray sensitivity and signal-to-noise performance. Towards this goal, this work constructs and experimentally investigates the x-ray imaging performance of a novel direct-indirect prototype imager referred to as Hybrid AMFPI. The imager comprises a direct conversion a-Se layer that may be coupled to an interchangeable scintillator screen through a transparent blocking layer and bias electrode. In this direct-indirect “hybrid” configuration, a-Se serves as both an x-ray and optical sensor. Readout is performed by a thin-film transistor array with 85 μm pixel pitch. The prototype imager’s x-ray sensitivity, modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) are measured in a direct AMFPI configuration (i.e. a-Se alone) and in a Hybrid configuration under identical x-ray exposure conditions and the results are compared. Contrast-detail and spatial resolution phantoms are also imaged using direct, Hybrid and indirect AMFPI configurations under identical exposure conditions to evaluate differences in their imaging performance.