Simon Eckstein

Simon Eckstein

Auto-generated profile, based on publicly available information

Simon Eckstein

Fraunhofer Institute for Manufacturing Engineering and Automation, Nobelstraße 12, 70569, Stuttgart, Germany; Institute of Industrial Manufacturing and Management, University of Stuttgart, Allmandring 35, 70569, Stuttgart, Germany; Graduate School of Excellence advanced Manufacturing Engineering (GSaME), University of Stuttgart, Nobelstraße 12, 70569, Stuttgart, Germany

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2025 in Applied Ergonomics
Verified
Journal Article
Open access
Mark TrösterMark Tröster
Mark Tröster
SESimon Eckstein
Simon Eckstein
PKPaula Kennel
Paula Kennel
VKVerena Kopp
Verena Kopp
ABAlina Benkiser
Alina Benkiser
TBThomas Bauernhansl
Thomas Bauernhansl
Human-centred and ergonomic work design is one of the most important drivers for increasing the competitiveness of the European Union. As a flexible, person-specific occupational measure, exoskeletons promise great potential for effectively reducing individual ergonomic stress. Digital human models can provide important insights and offer great potential for systematising the effect and targeted use of exoskeletons, supporting their effective implementation in practice. In this article, digital human models are applied on two levels. Firstly, a realistic industrial logistics scenario in which boxes had to be relocated is designed with the help of a digital human model for workplace and process planning and secondly, a new biomechanical evaluation methodology to analyse intended and unintended effects on internal stress on the human body is demonstrated by applying musculoskeletal exoskeleton human models of four test subjects. Finally, the modelled biomechanical support tendencies of one exoskeleton are preliminary validated using EMG measurement data of the back muscles collected from the four male workers. The preliminary analysis of two back-support exoskeletons to demonstrate the new methodological approach confirms the expected, intended effects in the lower back and reveals unintended effects, such as e.g. changes in knee kinetics when applying a soft or hard-frame exoskeleton. Furthermore, the exemplary results to demonstrate the methodological approach expose notable differences between the test subjects, which underlines the relevance of person-specific evaluation and consideration of exoskeleton support. The preliminary validation shows a correlation between the modelled and the EMG-measured biomechanical exoskeleton support of the considered back muscles.