14 August 2023 in IEEE Transactions on Instrumentation and Measurement
Superficial flow velocity perception is inspired by aquatic organisms and has become increasingly important for underwater robots and vehicles. Existing marine electromagnetic velometers require very large AC coils with high power consumption for excitation, limiting their mobility and underwater applications. Permanent magnet excitation is preferable for miniature flow sensors because of low power consumption, small size, and high sensitivity. However, permanent magnet excitation has not been applicable due to the high output drift caused by electrode polarization voltage. This paper proposes a permanent magnet-based flow velocity meter that measures the velocity based on the electrode output current instead of the output voltage. The relationship between the output current and the fluid velocity, fluid conductivity, permanent magnet parameters, and electrode position during permanent magnet excitation is derived, and a finite element simulation is conducted. A signal processing circuit is designed to obtain the current output. The experimental results show that the output drift ratio of the proposed sensor is 92% lower than that of the sensor measuring the voltage output, and the measurement R 2 is 0.998 in the test range of 0-0.875m/s.
4 March 2024 in IEEE Sensors Journal
Inspired by the flow perception ability of underwater organisms’ lateral line system, recently, the artificial lateral line system (ALLS) is showing highly competitive application prospect in AUVs. However, the existing ALLS contains lots of movable parts, which are easily to be damaged and entangled, and will generate flow resistance to the AUV carrier. Moreover, existing ALLS mainly focus on vibration objects detection, while the studies on the more common and valuable translational moving objects are relatively less. In this paper, a novel and practical theory for underwater moving objects detection is proposed to achieve no-contact object velocity estimation via the measured object wake flow signal. The object motion induced flow field and sensor signals are well studied. The signal processing method is established based on the array signals’ time delay features. A fully solid-state ALLS is proposed using permanent magnet based superficial electromagnetic flow velometer array without any movable parts. The experiment results proves that the proposed ALLS and the object velocity estimation method is ultra robust to the object shape and object distance changes. The object velocity estimation accuracy of the proposed ALLS reaches 96.64-99.96% within the range of 0-0.875 [m/s] and the maximum detection range reaches 0.14 [m] of the test 0.02 [m] width cuboid object at 0.5 [m/s].
26 November 2021 in JID Innovations
Sensitive, objective, and easily applied methods for evaluating skin lesions are needed to improve diagnostic accuracy. In this study, we evaluated whether a developed noninvasive electrical impedance dermography device URSKIN could serve this purpose. In this pilot study, 17 subjects with subsequently confirmed basal cell carcinoma underwent four-electrode electrical impedance dermography measurements to assess the electrical properties of basal cell carcinoma and adjacent normal skin. A linear mixed-effects model with random intercept and slope terms was used for the analysis of multifrequency values in longitudinal and transverse directions. A significant difference in the intercept of frequency trajectories was observed for the longitudinal conductivity of 0.13 siemens/m (P < 0.001, 95% confidence interval = 0.10–0.16), transverse conductivity of 0.06 siemens/m (P < 0.001, 95% confidence interval = 0.05–0.07), longitudinal relative permittivity (dimensionless) of 203,742 (P < 0.001, 95% confidence interval = 180,292–227,191), and transverse relative permittivity (dimensionless) of 86,894 (P < 0.001, 95% confidence interval = 81,549 – 92,238). Thus, our device detected significant electrical differences between basal cell carcinoma and adjacent normal skin. Given these preliminary performance metrics and the ease of use, this technology merits further study to establish its value in facilitating the clinical diagnosis of skin cancers.
1 April 2021 in Physiological Measurement
Objective. Electrophysiological assessment of the tongue volume conduction properties (VCPs) using our novel multi-electrode user tongue array (UTA) depressor has the promise to serve as a biomarker in patients with bulbar dysfunction. However, whether in vivo data collected using the UTA depressor accurately reflect the tongue VCPs remains unknown. Approach. To address this question, we performed in silico simulations of the depressor with an accurate anatomical tongue finite element model (FEM) using healthy human tongue VCP values, namely the conductivity and the relative permittivity, in the sagittal plane (i.e. longitudinal direction) and axial and coronal planes (i.e. transverse directions). We then established the relationship between tongue VCP values simulated from our model to measured human data. Main results. Experimental versus simulated tongue VCP values including their spatial variation were in good agreement with differences well within the variability of the experimental results. Tongue FEM simulations corroborate the feasibility of our UTA depressor in assessing tongue VCPs. Significance. The UTA depressor is a new non-invasive and safe tool to measure tongue VCPs. These electrical properties reflect the tongue’s ionic composition and cellular membrane integrity and could serve as a novel electrophysiological biomarker in neurological disorders affecting the tongue.
26 July 2022 in IEEE Transactions on Instrumentation and Measurement
Flow perception, as unique for underwater creature, is also the key components for underwater robots. However, due to strictly limitation on power consumption, flow resistance, volume and weight, to achieve flow perception ability artificialy is not easy in underwater robots. Different from the existing sensors, by using the stray field of permanent magnet, a novel surface flow velocity sensor is proposed with zero excitation power consumption, nearly zero flow resistance and considerable signal output. In this paper, based on the derived formula of electromagnetic induction with stray field, the relationship between electrode output voltage, permanent magnet stray field, surface flow field boundary layer and electrode position is established, and the spatial sensitivity distribution of sensor unit to surface flow field with optimal electrode position are studied. By using flexible surface printed electrode, when the fluid flows through the magnetic field area on the electrode surface, induced voltage proportional to the velocity is generated. Finally, the flow velocity perception ability of the sensor is verified by finite element simulation and experiments, and the sensitivity coefficients of the sensor under different electrode positions are compared. The proposed sensor can be used for any underwater vehicle to realize the perception of surface flow field without damaging the streamline shape. The intrinsic sensitivity of the sensor unit is 1.6 mV/(m∙ s-1) with the weight of 7.8 grams.
1 May 2021 in Physiological Measurement
Objective. Bioimpedance technology is experiencing an increased use to assess health in a wide range of new consumer, research and clinical applications. However, the interaction between tissues producing bioimpedance data is often unclear. Methods. This work provides a novel theoretical framework to model bioimpedance measurements of nonhomogeneous tissues. We consider five case studies to validate the usefulness of our approach against finite element model simulations. Results. Theoretical and FEM-simulated apparent resistance and reactance data were in good agreement, with a maximum relative errors <4% and <8%, respectively. Conclusion. The biophysics-driven framework developed provides compact analytical expressions to model nonhomogeneous bioimpedance measurements including multiple tissues with arbitrary shape and electrical properties. This work provides a new perspective to interpret nonhomogeneous bioimpedance measurements using series , parallel , and series-parallel circuit-like topology equivalents. Significance. Our framework is a new tool to better understand and describe complex nonhomogeneous biological measurements as, for example, cardiac, brain and respiratory applications using (non)invasive electrodes.