Aykut Aksit

Dr. Aykut Aksit

Columbia University
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2020 in Hearing Research
Verified
Journal Article
Closed access
BSBetsy Szeto
Betsy Szeto
AAAykut Aksit
Aykut Aksit
CVChris Valentini
Chris Valentini
MYMichelle Yu
Michelle Yu
EWEmily G. Werth
Emily G. Werth
ALAnil Lalwani
Anil Lalwani

2 June 2020 in Drug Delivery and Translational Research
Verified
Journal Article
Closed access
PDF file
AAAykut Aksit
Aykut Aksit
SRShruti Rastogi
Shruti Rastogi
MNMaria L. Nadal
Maria L. Nadal
APAmber M. Parker
Amber M. Parker
ALAnil K. Lalwani
Anil K. Lalwani
JKJeffrey W. Kysar
Jeffrey W. Kysar

8 June 2018 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
AAAykut Aksit
Aykut Aksit
DADaniel N. Arteaga
Daniel N. Arteaga
MAMiguel Arriaga
Miguel Arriaga
XWXun Wang
Xun Wang
HWHirobumi Watanabe
Hirobumi Watanabe
JKJeffrey W. Kysar
Jeffrey W. Kysar

1 February 2020 in Otology & Neurotology
Verified
Journal Article
Closed access
HCHarry Chiang
Harry Chiang
MYMichelle Yu
Michelle Yu
AAAykut Aksit
Aykut Aksit
WWWenbin Wang
Wenbin Wang
SSSagit Stern-Shavit
Sagit Stern-Shavit
ALAnil Lalwani
Anil Lalwani
Hypothesis: Three-dimensional (3D)-printed microneedles can create precise holes on the scale of micrometers in the human round window membrane (HRWM). Background: An intact round window membrane is a barrier to delivery of therapeutic and diagnostic agents into the inner ear. Microperforation of the guinea pig round window membrane has been shown to overcome this barrier by enhancing diffusion 35-fold. In humans, the challenge is to design a microneedle that can precisely perforate the thicker HRWM without damage. Methods: Based on the thickness and mechanical properties of the HRWM, two microneedle designs were 3D-printed to perforate the HRWM from fresh frozen temporal bones in situ (n = 18 total perforations), simultaneously measuring force and displacement. Perforations were analyzed using confocal microscopy; microneedles were examined for deformity using scanning electron microscopy. Results: HRWM thickness was determined to be 60.1 ± 14.6 (SD) μm. Microneedles separated the collagen fibers and created slit-shaped perforations with the major axis equal to the microneedle shaft diameter. Microneedles needed to be displaced only minimally after making initial contact with the RWM to create a complete perforation, thus avoiding damage to intracochlear structures. The microneedles were durable and intact after use. Conclusion: 3D-printed microneedles can create precise perforations in the HRWM without damaging intracochlear structures. As such, they have many potential applications ranging from aspiration of cochlear fluids using a lumenized needle for diagnosis and creating portals for therapeutic delivery into the inner ear.

1 February 2020 in Otology & Neurotology
Verified
Journal Article
Closed access
MYMichelle Yu
Michelle Yu
DADaniel N. Arteaga
Daniel N. Arteaga
AAAykut Aksit
Aykut Aksit
HCHarry Chiang
Harry Chiang
EOElizabeth S. Olson
Elizabeth S. Olson
ALAnil Lalwani
Anil Lalwani
Hypothesis: Microneedles can create microperforations in the round window membrane (RWM) without causing anatomic or physiologic damage. Background: Reliable delivery of agents into the inner ear for therapeutic and diagnostic purposes remains a challenge. Our novel approach employs microneedles to facilitate intracochlear access via the RWM. This study investigates the anatomical and functional consequences of microneedle perforations in guinea pig RWMs in vivo. Methods: Single three-dimensional-printed, 100 μm diameter microneedles were used to perforate the guinea pig RWM via the postauricular sulcus. Hearing was assessed both before and after microneedle perforation using compound action potential and distortion product otoacoustic emissions. Confocal microscopy was used ex vivo to examine harvested RWMs, measuring the size, shape, and location of perforations and documenting healing at 0 hours (n = 7), 24 hours (n = 6), 48 hours (n = 6), and 1 week (n = 6). Results: Microneedles create precise and accurate perforations measuring 93.1 ± 29.0 μm by 34.5 ± 16.8 μm and produce a high-frequency threshold shift that disappears after 24 hours. Examination of perforations over time demonstrates healing progression over 24 to 48 hours and complete perforation closure by 1 week. Conclusion: Microneedles can create a temporary microperforation in the RWM without causing significant anatomic or physiologic dysfunction. Microneedles have the potential to mediate safe and effective intracochlear access for diagnosis and treatment of inner ear disease.

17 September 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SLStephen Leong
Stephen Leong
AAAykut Aksit
Aykut Aksit
SFSharon J. Feng
Sharon J. Feng
JKJeffrey W. Kysar
Jeffrey W. Kysar
ALAnil Lalwani
Anil Lalwani
Objectives: Precision medicine for inner ear disorders has seen significant advances in recent years. However, unreliable access to the inner ear has impeded diagnostics and therapeutic delivery. The purpose of this review is to describe the development, production, and utility of novel microneedles for intracochlear access. Methods: We summarize the current work on microneedles developed using two-photon polymerization (2PP) lithography for perforation of the round window membrane (RWM). We contextualize our findings with the existing literature in intracochlear diagnostics and delivery. Results: Two-photon polymerization lithography produces microneedles capable of perforating human and guinea pig RWMs without structural or functional damage. Solid microneedles may be used to perforate guinea pig RWMs in vivo with full reconstitution of the membrane in 48–72 h, and hollow microneedles may be used to aspirate perilymph or inject therapeutics into the inner ear. Microneedles produced with two-photon templated electrodeposition (2PTE) have greater strength and biocompatibility and may be used to perforate human RWMs. Conclusions: Microneedles produced with 2PP lithography and 2PTE can safely and reliably perforate the RWM for intracochlear access. This technology is groundbreaking and enabling in the field of inner ear precision medicine.