Background: Circular economy (CE) has raised great interest as a concept and as a development model worldwide. This concept aims to provide a substitute for the linear economic model, which was based on production and consumption, continuous growth, and resources depletion. CE allows a greener economy with sustainable development and promotes more balanced societies. The healthcare sector is a major contributor to the climate crisis, with a carbon footprint representing 4.4% of global net emissions. It is thus essential to rethink the applicability of CE in healthcare. Methods: We conducted a scoping review guided by the Arksey and O’Malley methodological framework and utilised PRISMA-ScR (Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews) checklist. A systematic search from MEDLINE complete, SCOPUS, and Web of Science databases published between 1992 and 2022. Results: Through database searching a total of 1018 records were identified and 475 duplicates were removed. From the total search, 543 articles were screened by title/abstract according to the inclusion and exclusion criteria. After screening, 38 full-text articles were selected and assessed for eligibility. Forty-seven additional records were also identified through other sources and screened for eligibility. Other sources included: 12 articles from snowballing of previous papers; 9 articles following peer-reviewers suggestions; 19 reports from relevant organisations in CE and healthcare; two webpage, and one book. Conclusion: Specific areas were identified where hospitals could reduce their greenhouse gas (GHG) emissions and consequently their negative environmental impact, namely through waste management, energy, water, transportation/travel, hospital design, food optimisation, green procurement, and behaviour. Also, lack of staff awareness and knowledge of the environmental impact of healthcare, and hospitals sustainability were identified as major contributors.
The utilization of extended reality (ER) has been increasingly explored in the medical field over the past ten years. A comprehensive analysis of scientific publications was conducted to assess the applications of ER in the field of diagnostic imaging, including ultrasound, interventional radiology, and computed tomography. The study also evaluated the use of ER in patient positioning and medical education. Additionally, we explored the potential of ER as a replacement for anesthesia and sedation during examinations. The use of ER technologies in medical education has received increased attention in recent years. This technology allows for a more interactive and engaging educational experience, particularly in anatomy and patient positioning, although the question may be asked: is the technology and maintenance cost worth the investment? The results of the analyzed studies suggest that implementing augmented reality in clinical practice is a positive phenomenon that expands the diagnostic capabilities of imaging studies, education, and positioning. The results suggest that ER has significant potential to improve diagnostic imaging procedures’ accuracy and efficiency and enhance the patient experience through increased visualization and understanding of medical conditions. Despite these promising advancements, further research is needed to fully realize the potential of ER in the medical field and to address the challenges and limitations associated with its integration into clinical practice.
Global warming and the increase in greenhouse gases are a current concern worldwide. The healthcare sector constitutes about 4.4% of all emissions. This study aims to evaluate the knowledge, awareness and attitudes of Therapeutic Radiographers/Radiation Therapists (TR/RTTs) regarding environment-related concepts to inform the development of educational curriculum. A validated self-designed survey was distributed to TR/RTTs across Europe by the SAFE EUROPE partners and via social media between October 2021 and February 2022. The survey was divided into six sections: (i) demographics, (ii) knowledge of Circular Economy (CE) and Green Skills (GS), (iii) personal attitudes, (iv) TR/RTTs attitudes, (v) the importance of CE, and (vi) education. Questions consisted of mostly Likert scales complemented with other closed- and open-ended questions. 31%-42% of participants are aware of national and departmental policies in CE and GS concepts. Even though half of the participants considered that they advocate and practice CE, the open questions indicated that participants only focus on waste management, ignoring all the other dimensions of CE in healthcare. Personal attitudes and lifestyles also did not reflect CE. TR/RTTs considered CE practices and GS development essential. However, the suggested academic level at which these skills should be developed was split between High School (44%) and Bachelor's degree (32%). It is essential to raise awareness among TR/RTTs about the various dimensions of CE applied to healthcare: "green transportation", "environment-friendly procurement", "hospital building design", "food process optimisation", "water reduction", "energy efficiency", and "waste management". These GS must be developed by TR/RTTs to decrease their impact on the environment. Their training may need to be lifelong, starting during basic high school education and continuing as healthcare professionals after graduation.
1 June 2014 in Technology in Cancer Research & Treatment
Helical tomotherapy (HT) was introduced at the Greater Poland Cancer Centre (GPCC) in April 2009. Retrospective analysis included data from the treatments performed for the first 656 patients treated with HT between May 2009 and May 2012 at the GPCC. In order to evaluate the implications on daily workload and scheduling of patients, stepwise regression and time analysis for each component of the overall treatment time, such as positioning, imaging, registration, and irradiation were performed. A detailed analysis included: (1) learning curves and optimized time needed for positioning and registration; (2) relation between irradiation time and parameters used for plan creation; and (3) average time of daily imaging. The irradiation component has the highest influence on the overall treatment time (R = 0.911). The lowest influence was observed for the imaging (R = 0.670). The learning curve for positioning was 7 months while the reduction of the average daily time needed for registration was observed even after two years. The irradiation time strongly depends on the planning parameters. Changing the pitch from 0.215 to 0.287 for pelvic cancer cases decreased the average daily beam-on time per patient by about 2 minutes. Similar changes for head and neck reduced this time by 1.3 minutes. The limitation in the usage of 1 cm field width only for complex cases, lower than 10 cm in the cranio-caudal direction, reduced the beam-on time per patient by 2 minutes. The average overall treatment time decreased from 21.5 minutes per patient in the first year of the HT usage to 13.8 minutes per patient in current practice. Our current practice shows that for a group of patients including mainly those with pelvis and head and neck cancers, the HT treatment takes approximately 15 minutes per patient allowing 40 patients to be treated within 10 hours.
1 April 2013 in Journal of Medical Imaging and Radiation Oncology
To compare DVHs for OARs in two different positions - prone and supine - for prostate cancer patients irradiated with a Tomotherapy unit. In the era of dose escalation, the choice of optimal patient immobilization plays an essential role in radiotherapy of prostate cancer. The study included 24 patients who were allocated to 3 risk groups based on D'Amico criteria; 12 patients represented a low or intermediate and 12 a high risk group. FOR EACH PATIENT TWO TREATMENT PLANS WERE PERFORMED: one in the supine and one in the prone position. PTV included the prostate, seminal vesicles and lymph nodes for the high risk group and the prostate and seminal vesicles for the intermediate or low risk groups. DVHs for the two positions were compared according to parameters: Dmean, D70, D50 and D20 for the bladder and rectum and Dmean, D10 for the intestine. The position accuracy was verified using daily MVCT. Prone position was associated with lower doses in OARs, especially in the rectum. Despite the fact that in the entire group the differences between tested parameters were not large, the Dmean and D10 for the intestine were statistically significant. In the case of irradiation only to the prostate and seminal vesicles, the prone position allowed for substantial reduction of all tested DVH parameters in the bladder and rectum, except D20 for bladder. Moreover, the Dmean and D50 parameter differences for the bladder were statistically significant. No significant differences between positions reproducibility were demonstrated. In patients irradiated to prostate and seminal vesicles, the prone position may support sparing of the rectum and bladder. The reproducibility of position arrangement in both positions is comparable.