Beatriz Alemón

Dr. Beatriz Alemón

Tecnológico de Monterrey
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Salvador Ibarra AguilaSalvador Ibarra Aguila
Salvador Ibarra Aguila
GSGisel J. Sánchez
Gisel J. Sánchez
ESEric Sauvain
Eric Sauvain
BABeatriz Alemón
Beatriz Alemón
RFRita Q. Fuentes-Aguilar
Rita Q. Fuentes-Aguilar
JHJoel Huegel
Joel Huegel
The interface pressure between the residual limb and prosthetic socket has a significant effect on the amputee’s mobility and level of comfort with their prosthesis. This paper presents a socket interface pressure (SIFP) system to compare the interface pressure differences during gait between two different types of prosthetic sockets for a transtibial amputee. The system evaluates the interface pressure in six critical regions of interest (CROI) of the lower limb amputee and identifies the peak pressures during certain moments of the gait cycle. The six sensors were attached to the residual limb in the CROIs before the participant with transtibial amputation donned a prosthetic socket. The interface pressure was monitored and recorded while the participant walked on a treadmill for 10 min at 1.4 m/s. The results show peak pressure differences of almost 0.22 kgf/cm2 between the sockets. It was observed that the peak pressure occurred at 50% of the stance phase of the gait cycle. This SIFP system may be used by prosthetists, physical therapists, amputation care centers, and researchers, as well as government and private regulators requiring comparison and evaluation of prosthetic components, components under development, and testing.

21 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MBMariana Ballesteros
Mariana Ballesteros
MLManuel A. Lopez-Perez
Manuel A. Lopez-Perez
RFRita Q. Fuentes-Aguilar
Rita Q. Fuentes-Aguilar
PCPedro E. Chavarrias-Solano
Pedro E. Chavarrias-Solano
BABeatriz Alemón
Beatriz Alemón
JHJoel Huegel
Joel Huegel
This work describes the development of a controlled cabin for capturing and analyzing thermal images. The motivation of such a device is to aid in the thermal image acquisition process within a confined space. The thermograms generated provide helpful information for analyzing the residual human limb in subjects with transtibial amputation. Such a study proposes a non-intrusive method to study the thermal activity on the amputee residual limb and seek a correlation to the quality of the socket. The proposed cabin ensures the repeatability of the thermograms acquisition process and provides an isolated workspace, thus improving the quality of the samples. The methodology consists of the design of the mechanical elements and parts of the system on computer-aided design software, the electronic instrumentation, a graphic user interface, and the control algorithm based on a barrier Lyapunov function to solve the trajectory tracking for the camera movements, and numerical simulations to illustrate the functionality and the manufacture of a prototype. The results obtained by implementing the control design on the automated cabin reveal that the thermal image acquisition process is completed following the desired trajectory with a mean squared tracking error of 0.0052. In addition, an example of the thermal images of two subjects and the results processing this class of pictures using the designed interface is shown.

19 December 2025 in Machines
Verified
Journal Article
Open access
PDF file
CPCesar Daniel Pizarro
Cesar Daniel Pizarro
JHJoel Huegel
Joel Huegel
EDElias Diaz
Elias Diaz
BABeatriz Alemón
Beatriz Alemón
HHHugh Herr
Hugh Herr
L. C. Félix-HerránL. C. Félix-Herrán
L. C. Félix-Herrán
Since elevated temperature and humidity may occur at the prosthetic socket–skin interface, it is essential to collect thermal data from the residual limb, as this information serves as an indicator of adverse effects such as irritation, postural problems, and significant damage to health. These data are obtained non-invasively through the execution of a thermal imaging (TI) procedure. However, the precision and repeatability of a TI procedure rely significantly on its execution technique. This work presents the design and implementation of a mechatronic device that automates a thermal imaging technique. The application of the device is in lower-limb prosthetics evaluation. The proposed system improves data acquisition consistency by reducing execution time and minimizing human error, thereby enhancing the reproducibility and reliability of thermal measurements. The introduced device, Thermal Imaging Booth, proposes an automated solution for TI standardization in clinical and research settings. By minimizing inconsistencies, this system improves the diagnostic potential of thermography, facilitating its adoption in biomedical applications.