Binoe Abuan

Dr. Binoe Abuan

University of the Philippines Diliman

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Renewable Energy
Verified
Journal Article
Open access
BABinoe Abuan
Binoe Abuan
RHRobert J. Howell
Robert J. Howell

22 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
SMSy Miguel
Sy Miguel
BABinoe Abuan
Binoe Abuan
Louis Angelo DanaoLouis Angelo Danao
Louis Angelo Danao
Wind energy is one of the fastest growing renewable energy sources, and the most developed energy extraction device that harnesses this energy is the Horizontal Axis Wind Turbine (HAWT). Increasing the efficiency of HAWTs is one important topic in current research with multiple aspects to look at such as blade design and rotor array optimization. This study looked at the effect of wingtip devices, a split winglet, in particular, to reduce the drag induced by the wind vortices at the blade tip, hence increasing performance. Split winglet implementation was done using computational fluid dynamics (CFD) on the National Renewable Energy Lab (NREL) Phase VI sequence H. In total, there are four (4) blade configurations that are simulated, the base NREL Phase VI sequence H blade, an extended version of the previous blade to equalize length of the blades, the base blade with a winglet and the base blade with split winglet. Results at wind speeds of 7 m/s to 15 m/s show that adding a winglet increased the power generation, on an average, by 1.23%, whereas adding a split winglet increased it by 2.53% in comparison to the extended blade. The study also shows that the increase is achieved by reducing the drag at the blade tip and because of the fact that the winglet and split winglet generating lift themselves. This, however, comes at a cost, i.e., an increase in thrust of 0.83% and 2.05% for the blades with winglet and split winglet, respectively, in comparison to the extended blade.

23 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
VAVirgel Arocena
Virgel Arocena
BABinoe Abuan
Binoe Abuan
JRJoseph Gerard Reyes
Joseph Gerard Reyes
PRPaul L. Rodgers
Paul L. Rodgers
Louis Angelo DanaoLouis Angelo Danao
Louis Angelo Danao
Pump intake structure design is one area where physical models still remain as the only acceptable method that can provide reliable engineering results. Ensuring the amount of turbulence, entrained air vortices, and swirl are kept within acceptable limits requires site-specific, expensive, and time-consuming physical model studies. This study aims to investigate the viability of Computational Fluid Dynamics (CFD) as an alternative tool for pump intake design thus reducing the need for extensive physical experiments. In this study, a transient multiphase simulation of a 530 mm wide rectangular intake sump housing a 116 m3/h pump is presented. The flow conditions, vortex formation and inlet swirl are compared to an existing 1:10 reduced scaled physical model test. For the baseline test, the predicted surface and submerged vortices agreed well with those observed in the physical model. Both the physical model test and the numerical model showed that the initial geometry of the pump sump is unacceptable as per ANSI/HI 9.8 criteria. Strong type 2 to type 3 submerged vortices were observed at the floor of the pump and behind the pump. Consequently, numerical simulations of proposed sump design modification are further investigated. Two CFD models with different fillet-splitter designs are evaluated and compared based on the vortex formation and swirl. In the study, it was seen that a trident-shaped splitter design was able to prevent flow separation and vortex suppression as compared to a cross-baffle design based on ANSI/HI 9.8. CFD results for the cross-baffle design showed that backwall and floor vortices were still present and additional turbulence was observed due to the cross-flow caused by the geometry. Conversely, CFD results for the trident-shaped fillet-splitter design showed stable flow and minimized the floor and wall vortices previously observed in the first two models.

18 August 2021 in Energies
Verified
Journal Article
Open access
PDF file
VAVirgel Arocena
Virgel Arocena
BABinoe Abuan
Binoe Abuan
JRJoseph Gerard Reyes
Joseph Gerard Reyes
PRPaul L. Rodgers
Paul L. Rodgers
Louis Angelo DanaoLouis Angelo Danao
Louis Angelo Danao
Like any other turbomachinery, it is essential that the hydraulic behavior and performance of mixed-flow pumps are evaluated way in advance prior to manufacturing. Pump performance relies heavily on the proper design of the intake structure. Intake structures should be accurately designed in order to minimize and avoid unnecessary swirl and vortex formations. Ensuring the optimum performance condition as well as predicting how a particular intake structure affects the efficiency of the pump often requires either physical model studies or theoretical evaluations. Unfortunately, physical models are costly, time-consuming, and site-specific. Conversely, design and performance predictions using a theoretical approach merely gives performance values or parameters, which are usually unable to determine the root cause of poor pump performance. This study evaluates the viability of using Computational Fluid Dynamics (CFD) as an alternative tool for pump designers and engineers in evaluating pump performance. A procedure for conducting CFD simulations to verify pump characteristics such as head, efficiency, and flow as an aid for preliminary pump design is presented. Afterwards, a multiphase simulation using the VOF approach is applied to compare the fluid dynamics between four different pump intake structures. A full-sized CFD model of the pump sump complete with the pump’s active components was used for the intake structure analysis in order to avoid scaling issues encountered during the reduced-scale physical model test. The results provided a clear illustration of the hydraulic phenomena and characteristic curves of the pump. A performance drop in terms of reduction in TDH was predicted across the various intake structure designs. The CFD simulation of intake structure provided a clear insight on the varying degree of swirl, flow circulation, and effect on pump efficiency between all four cases.

16 August 2021 in Fluids
Verified
Journal Article
Open access
PDF file
IMIan Jay T. Matias
Ian Jay T. Matias
Louis Angelo DanaoLouis Angelo Danao
Louis Angelo Danao
BABinoe Abuan
Binoe Abuan
Two-dimensional computational fluid dynamics (CFD) simulations are employed to investigate the effects of adding a circular-arc-shaped windshield on the performance of a Banki type vertical axis wind turbine (VAWT), particularly to the application where the VAWT is harnessing wind energy in highway caused by the passing vehicles. Unsteady Reynolds-Averaged Navier-Stokes (URANS) is the computational approach used to calculate the turbulent flow within the domain. Two sets of simulation cases based on two different vehicles (i.e., car and a bus) are performed with varying arc-length of the windshield. The results show that the windshield provides an increase in the energy captured by the VAWT by up to 16.14% compared to no windshield case when the car model is used. In contrast, windshield in all the simulation cases using a bus model gives a negative effect to VAWT performance where the worst case yields −64.77%.

30 December 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
GGGlecelyn M. Galvez
Glecelyn M. Galvez
KOKarl Andrie M. Olivar
Karl Andrie M. Olivar
FTFrancis Rey G. Tolentino
Francis Rey G. Tolentino
Louis Angelo DanaoLouis Angelo Danao
Louis Angelo Danao
BABinoe Abuan
Binoe Abuan
The fabrication route for tidal turbine blades has been compounded with the appearance of additive manufacturing; with the use of infill patterns, improvement of mechanical strength and material reduction for 3D printed parts can be obtained. Through finite element analysis and three-point bend tests, the optimal infill lattice pattern, and the viability of the shell–infill turbine blade model as an alternative to the conventional shell-spar model was determined. Out of a selection of infills, the best infill pattern was determined as the hexagonal infill pattern oriented in-plane. A representative volume element was modeled in ANSYS Material Designer, resulting in the homogenized properties of the in-plane hexagonal lattice. After validation, the homogenized properties were applied to the tidal turbine blade. The shell–infill model was based on the volume of the final shell-spar model which had a blade deflection of 9.720% of the blade length. The difference in the deflection between the homogenized infill and the spar cross-section was 0.00125% with a maximum stress of 170.3 MPa which was within the tensile strength and flexure strength of the carbon fiber with onyx base material. Conclusively, the homogenized infill was determined as a suitable alternative to the spar cross-section. The best orientation of the infill relative to the horizontal orientation of the blade was 0 degrees; however, the lack of trend made it inconclusive whether 0 degrees was the absolute optimal infill orientation.