Begüm Yalçın

Ms. Begüm Yalçın

Department of Biomedical Engineering, Acıbadem University, Istanbul, İstanbul, Turkey (Türkiye)
orcid
Ph.D. Candidate & Research Assistant

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2020 in International Journal of Performance Analysis in Sport
Verified
Journal Article
Closed access
HAHande Argunsah
Hande Argunsah
Begüm YalçınBegüm Yalçın
Begüm Yalçın
Biofeedback is used for enhancing performance through providing real-time stimulus to the individual during physical activities. This randomised controlled trial aimed investigating the changes in physiological and kinematic variables of treadmill running in response to biofeedback. 24 age-matched, healthy, and recreationally active participants were randomly assigned to biofeedback and no-biofeedback groups. During 15-min treadmill running, group-based knee ROM, COM and heart rate were collected and analysed. Heart rate change was statistically significant for no-biofeedback group (156.60 ± 5.18, 160.20 ± 5.22 and 163.60 ± 5.93 F (2, 9) = 13.878, p < 0.001). No such change was found for biofeedback group (152.20 ± 6.63, 152.10 ± 6.12 and 155.30 ± 6.22 F (2, 9) = 2.787, p = 0.088). According to the Pearson Correlation Coefficient and RMSE techniques knee movement was highly correlated (initial-mid R2 = 0.995, RMSE = 1.558; initial-final R2 = 0.994, RMSE = 1.407) for biofeedback group compared to no biofeedback group (initial-mid R2 = 0.989, RMSE = 1.988; initial-final R2 = 0.985, RMSE = 4.978). Heart rate and COM variability were minimised; correspondingly, consistent knee movement was obtained in biofeedback group. Future research should determine if muscle involvement in motion and fatigue are regulated with biofeedback.

1 January 2023 in Acta of Bioengineering and Biomechanics
Verified
Journal Article
Closed access
HAHande Argunsah
Hande Argunsah
Begüm YalçınBegüm Yalçın
Begüm Yalçın
Purpose Children with Cerebral Palsy have limitations in utilizing neural information to perform smooth movement and maintain balance during walking. This study aimed to develop a wearable sensor that tracks balance continuously and provides haptic biofeedback to its user through real-time vibration stimulus to assist patients with balance and postural control impairments such as cerebral palsy. Methods Twelve children with cerebral palsy and 12 age-matched typically developed children used the sensor during walking at a self-selected speed. The lower extremity joint kinematics, center of mass, and spatial-temporal parameters were recorded with Xsens MVN during “with” and “without” biofeedback conditions. Results The sensor did not disturb healthy gait. Pearson Correlation Coefficient and Root Mean Square Error techniques showed that biofeedback regulated the gait parameters and trunk stability of the CP group when biofeedback was given. The extended stance percentage (without BF: 73.91% ± 10.42, with BF: 63.53% ± 2.99), step width (without BF: 0.20m ± 0.05, with BF: 0.18m ± 0.07), and step time (without BF: 1.55s ± 1.07, with BF: 0.73s ± 0.14) parameters decreased; similarly, cadence and walking speed increased. Conclusions Obtained results indicated that this wearable sensor can be integrated into the physical therapy and rehabilitation process of children with balance and postural control impairments to improve motor learning and balance control. The present findings contribute to a better understanding of the adaptation of innovative engineering applications with rehabilitation processes, which in turn could assist patients with balance impairments and facilitate their integration into society.

1 November 2017
Verified
Conference Paper
Closed access
Begüm YalçınBegüm Yalçın
Begüm Yalçın
HBHande Argunsah Bayram
Hande Argunsah Bayram
MBMehmed B. Bayram
Mehmed B. Bayram
AIAnil Isik
Anil Isik
Biological feedback mechanisms are commonly used in sports and rehabilitation for the purpose of increasing motivation and performance of the athletes/ patients through tactile, audial and visual feedback in real-time. Biological feedback methods favor motor learning by improving motor control in static and dynamic tasks by augmenting motor information that makes it a helpful tool for improving balance, motor control and performance during training. This study aimed exploring the quantification of heart rate optimization via heart rate sensor as well as knee joint range of motion and center of mass during running on treadmill at self-selected pace with and without biological feedback using XSENS MVN (Xsens Technologies BV (Netherlands ®)) wearable 3D motion analysis system. POLAR H10 (Polar, USA) sensor was used to monitor heart rate simultaneously. Therefore, the biological feedback mechanisms used in this investigation not only improved the benefits of the training on treadmill by altering motivation but also explored the advantages of using biological feedback in improving balance and motor control. The data obtained from 10 healthy, unprofessional young participants. The results showed that biological feedback assisted the participants in obtaining more symmetrical, balanced and sustainable training.

23 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
HAHande Argunsah
Hande Argunsah
Begüm YalçınBegüm Yalçın
Begüm Yalçın
MEMehmet Alper Ergin
Mehmet Alper Ergin
GCGokay Coruhlu
Gokay Coruhlu
MYMustafa Yalcin
Mustafa Yalcin
ZGZeynep Guven
Zeynep Guven
Effective upper-extremity rehabilitation requires intensive and precise movement training, yet conventional therapies lack accurate motion tracking. Robotic exoskeletons address this limitation but are often hindered by ergonomic misalignment and limited adaptability. The AssistOn-Arm, a novel self-aligning exoskeleton, integrates ergonomic design and back-drivable actuation to enhance comfort and facilitate natural user interaction. This study aimed to assess the usability and ergonomics of the device in healthy participants and to conduct a pilot clinical evaluation in individuals with upper-extremity impairments. Thirty healthy participants and twelve patients with shoulder impairments performed predefined tasks under participant-active and device-active conditions. Kinematic data captured concurrently with AssistOn-Arm and Xsens MVN demonstrated strong agreement between conditions. Quantitative analysis revealed no significant differences (p > 0.05) in flexion, elevation, abduction–adduction, and external rotation, indicating reliable alignment with natural joint axes. Significant differences (p < 0.05) were observed only in sagittal hyperextension and internal rotation, reflecting device mechanical constraints. The study confirms the clinical feasibility of AssistOn-Arm as a sensor-driven, self-aligning exoskeleton that bridges engineering innovation and precision rehabilitation, paving the way for its integration into clinical practice.

1 January 2025 in Acta of Bioengineering and Biomechanics
Verified
Journal Article
Closed access
ZKZeynep Katircioglu
Zeynep Katircioglu
Begüm YalçınBegüm Yalçın
Begüm Yalçın
AIAnil Isik
Anil Isik
MYMelda P. Yargic
Melda P. Yargic
HAHande Argunsah
Hande Argunsah
Purpose This study investigates inter-limb asymmetry during drop vertical jumps in elite female football players by examining biomechanical variables—such as joint kinematics and ground reaction forces—that are strongly associated with increased anterior cruciate ligament injury risk. Methods Kinematic and kinetic parameters of 12 football players performing a vertical drop jump from a 30 cm high box were recorded using the Xsens MVN Awinda motion capture system and Vald Force Decks. Results The findings revealed significant differences in range of motion between the limbs, particularly in internal/external rotation and dorsiflexion/plantarflexion (p < 0.05). No significant differences were found in abduction/adduction or flexion-extension ROM between limbs during both landing phases. Internal/external rotation range differed significantly during the first landing phase (p < 0.05) but not the second. Hip joint flexion/extension exhibited minimal variation compared to the ankle and knee, with slight increases observed at the hip. From a kinetic standpoint, concentric mean power demonstrated a strong positive correlation with peak power (ρ = 0.903), underscoring its crucial role in optimizing performance and mitigating injury risk. Conclusions The study evaluated biomechanical indicators strongly linked to ACL injury risk. Findings highlight that asymmetrical loading and movement patterns—especially knee valgus and inter-limb discrepancies—may predispose female athletes to non-contact ACL injuries. These results emphasize the need for neuromuscular training interventions targeting symmetry, proprioception, and controlled landing to reduce injury risk and enhance performance.

5 August 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Begüm YalçınBegüm Yalçın
Begüm Yalçın
Yiğit Can GökhanYiğit Can Gökhan
Yiğit Can Gökhan
HŞHülya Şirzai
Hülya Şirzai
GYGunes Melek Yavuzer
Gunes Melek Yavuzer
HAHande Argunsah
Hande Argunsah
Background: Quantitative assessment of dynamic balance remains challenging in clinical practice. Wearable inertial measurement unit (IMU)-based technologies offer an objective and accessible approach for monitoring postural control. This study aimed to develop and preliminarily validate a wearable IMU-based trunk sway monitoring system (SwayTracker) and investigate trunk sway characteristics in stroke patients walking with and without arm sling support. Methods: A sternum-mounted IMU system was developed to quantify dynamic trunk sway during walking. Fifteen healthy adults and fourteen stroke patients participated. The healthy participants established normative reference values, whereas the stroke patients completed walking trials with and without arm sling support. Trunk sway was quantified using anteroposterior (AP) and mediolateral (ML) deviations and a polar-coordinate-based sway model. Results: The healthy reference cohort exhibited a mean trunk sway magnitude (radius) of 8.20 ± 3.16°. The stroke patients demonstrated greater sway during unsupported (15.36 ± 5.83°) and sling-assisted walking (15.35 ± 4.59°). Although overall sway magnitude remained unchanged, the mean sway direction shifted from 69.49° to 110.20°, indicating a redistribution of trunk sway from the anterior-right toward the anterior-left quadrant. Forward sway remained the dominant AP component, whereas ML sway shifted from predominantly rightward to leftward with sling use. Conclusions: SwayTracker provides a feasible method for objective assessment of dynamic trunk sway during walking. The stroke patients exhibited increased sway magnitude and altered directional organization compared with healthy individuals. Arm sling use primarily modified ML postural compensation patterns rather than reducing overall trunk sway, highlighting the potential of wearable trunk sway monitoring for gait and balance assessment in neurological rehabilitation.