The seismic performance assessment of dry-joint masonry arches is challenging because of their unique structural characteristics. Widely used assessment methods developed for frame-type structures require the use of a material-dependent section response. In contrast, the response of a dry-joint arch is not dependent on the material capacity but characterized by the sustainment of stability, primarily depending on rigid body rotation or sliding motion at the interfaces between the adjacent voussoirs. A hybrid methodology, combining a simple finite element micro model with principles of limit analysis method, is proposed in this work for the seismic performance assessment of these structures. The nonlinearity is concentrated at interfaces of the model by means of shear and compression-only axial springs. Kinematic conditions yielding a possible collapse mechanism were traced at every step of the time history analysis by checking the failure of individual interfaces. The procedure is applied to an ancient dry-joint Roman arch bridge in close proximity to the North Anatolian fault subject to significant seismic risk. Along with the performance of the system in its current state, the effects of retrofitting measures were investigated in the scope of this study.
1 August 2017 in Journal of Performance of Constructed Facilities
Seismic performance assessment of existing buildings requires the existing material’s properties to be determined as this has a significant influence on the seismic risk. As one of the most common construction type in Turkey, masonry buildings are assessed generally based on the recommended material properties specified in relevant codes as opposed to testing of samples taken from the existing buildings. However, due to different material types and workmanship quality, the specified properties might be quite different from the existing values. For these reasons, a comprehensive study has been undertaken to investigate the influence of mechanical properties of existing masonry buildings on their seismic performance. The study has two parts. First, the mechanical properties of materials commonly used in the Turkish masonry construction were determined by extracting wallets from existing structures and conducting laboratory experiments. The second part of the study was devoted to seismic performance assessment of selected buildings using material properties determined based on field tests and values specified in the codes. Within the context of determining existing mechanical properties, compression, diagonal tension, and shear tests were conducted on the specimens taken from existing buildings. Stress-strain responses for compression and diagonal tension tests were measured. When compared with the allowable strength values recommended by the current Turkish design code, the test results indicated significant differences from code recommended values. Thus, building assessment results were found to be greatly influenced by the material strength estimations. Based on the evaluation of material test results, lower-bound material properties are proposed for use in assessment of masonry buildings.
Tuğla duvarlar sağlam ve uzun ömürlü olmalarına rağmen farklı sebeplerle yıkıma maruz kalırlar. Bu çalışma Ankara Çiğdem Mahallesinde 1990’larda inşa edilmiş tuğla duvar dolgulu betonarme bir kooperatif binasının yıkım sürecini sunmaktadır. Yıkım sonrası atık olarak sahada biriken yatay delikli tuğla duvar parçaları incelenmiş ve yeniden kullanıma uygun olabilecekleri gözlenmiştir. Tuğlalar, sıva ve harç numuneleri laboratuvarda basınç testine, duvar parçaları da başlangıç kayma dayanımı testine tabi tutulmuştur. Elde edilen mukavemet değerleri ve ölçülen diğer fiziksel özellikler ilgili standartlardaki değerlerden yüksek olduğu için kullanılmalarının uygun olduğu sonucuna varılmış ve uygun bir yeniden kullanım metodu sunulmuştur. Son olarak, bu metot temel alınarak yıkımda oluşan genel duvar atıklarının kurtarılması için nasıl düzenlemeler yapılabileceği tartışılmıştır.
Moskova Rusya’da inşa edilen Kashirskaya alışveriş merkezinde, mimari gereksinimlerle, cam korkuluklar öngörülmüştür. İmalatçı tasarımında gereken birtakım değişiklikler sonucu en çok kullanılan ve gerçek ölçülerdeki büyük panellerin yapısal güvenliğinin deneylerle doğrulanması istenmiştir. Bu amaçla cam korkulukların ve bağlantı elemanlarının 3 boyutlu sonlu elemanlar modeli oluşturularak ilgili yönetmeliklere göre taşıma gücü ve deplasman hesapları yapılıp sonuçlar ODTU Yapı Mekaniği Laboratuvarı`nda tam ölçekli cam korkuluklar üzerinde gerçekleştirilen deneylerle doğrulanmıştır.