Brian Keith Foutch

Prof. Dr. Brian Keith Foutch

University of the Incarnate Word
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
JSJames M. Stringham
James M. Stringham
PGPaul V. Garcia
Paul V. Garcia
PSPeter A. Smith
Peter A. Smith
LMLeon N. McLin
Leon N. McLin
Brian Keith FoutchBrian Keith Foutch
Brian Keith Foutch
Purpose. One theory of macular pigment's (MP) presence in the fovea is to improve visual performance in glare. This study sought to determine the effect of MP level on three aspects of visual performance in glare: photostress recovery, disability glare, and visual discomfort. Methods. Twenty-six subjects participated in the study. Spatial profiles of MP optical density were assessed with heterochromatic flicker photometry. Glare was delivered via high-bright-white LEDs. For the disability glare and photostress recovery portions of the experiment, the visual task consisted of correct identification of a 1° Gabor patch's orientation. Visual discomfort during the glare presentation was assessed with a visual discomfort rating scale. Pupil diameter was monitored with an infrared (IR) camera. Results. MP level correlated significantly with all the outcome measures. Higher MP optical densities (MPODs) resulted in faster photostress recovery times (average P < 0.003), lower disability glare contrast thresholds (average P < 0.004), and lower visual discomfort (P = 0.002). Smaller pupil diameter during glare presentation significantly correlated with higher visual discomfort ratings (P = 0.037). Conclusions. MP correlates with three aspects of visual performance in glare. Unlike previous studies of MP and glare, the present study used free-viewing conditions, in which effects of iris pigmentation and pupil size could be accounted for. The effects described, therefore, can be extended more confidently to real-world, practical visual performance benefits. Greater iris constriction resulted (paradoxically) in greater visual discomfort. This finding may be attributable to the neurobiologic mechanism that mediates the pain elicited by light.

1 April 2015 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
JSJames Stringham
James Stringham
PGPaul V. Garcia
Paul V. Garcia
PSPeter A. Smith
Peter A. Smith
PHPaul L. Hiers
Paul L. Hiers
LMLeon N. McLin
Leon N. McLin
Brian Keith FoutchBrian Keith Foutch
Brian Keith Foutch
Purpose. By reducing rod intrusion and improving efficiency of neural signaling throughout the visual system, macular pigment (MP) could improve many aspects of visual performance in low-light level conditions. We examined this possibility for spatial resolution, dark adaptation kinetics, and color detection. Methods. Twenty-seven subjects participated in the study. Spatial profiles of MP optical density (MPOD) were determined using heterochromatic flicker photometry. Mesopic- and scotopic-adaptation level experiments were conducted in Maxwellian view. Results. Subjects with higher MP optical density (MPOD) required significantly lower contrast to detect the mesopic-level resolution targets; this effect became stronger with increasing spatial frequency. Dark adaptation recovery times were significantly faster as a function of MPOD (by nearly two minutes for the lowest mesopic-level task [high vs. low MPOD]; p < 0.001). Absolute scotopic thresholds were also significantly associated with MPOD (p < 0.001). MPOD was inversely associated with detection of yellow (p < 0.001), and, paradoxically, approached a significant positive correlation with the detection of blue (p = 0.06). Conclusions. MP appears to enhance visual function in low light conditions. Based on the results of this study, it can be said that MP extends the range of foveal vision into lower light. Additionally, MP appears to enhance dark adaptation kinetics, which suggests that increased MPOD leads to more efficient photopigment regeneration. The findings of the color detection portion of the study are suggestive of an active compensatory mechanism that offsets absorption by MP in order to maintain normal color perception.

18 October 2021 in Vision
Verified
Journal Article
Open access
PDF file
Lourdes Lourdes Alarcon FortepianiLourdes Lourdes Alarcon Fortepiani
Lourdes Lourdes Alarcon Fortepiani
Brian Keith FoutchBrian Keith Foutch
Brian Keith Foutch
MWMolly R. Wilson
Molly R. Wilson
The primary goal of this study was to investigate the effects of sex, oral contraceptive (OC) use, and menstrual cycle phase on common ocular parameters assessed during ophthalmic evaluations, namely intraocular pressure (IOP), central corneal thickness (CCT), and foveal thickness (FT), in young healthy adults. We measured IOP, CCT, and FT in 60 participants (16 men, 16 contraceptive users, and 28 cycling women) over two sessions that characterized the menstrual cycle phase in women. For men in our study, two sessions were separated by two weeks. For women, the two sessions were scheduled during the follicular and luteal phases of the menstrual cycle. There was a trend towards higher IOP in men, and the difference was significant for white, non-Hispanic subjects and for white subjects considered separately. There was also a trend for thicker corneas in women, but men had significantly thicker foveae. CCT and FT were not different between men and OC-users, hinting at a moderating hormonal effect of oral contraceptive use. We found that IOP, CCT, and FT were equivalent between the follicular and luteal phases, which may be owing to the timing of our sessions. However, our findings strongly suggest that clinicians should consider contraceptive use during routine ophthalmic evaluations, as it could inform glaucomatous risk in women.

1 May 2014 in JAAPA
Verified
Journal Article
Closed access
DVDerrick F. Varner
Derrick F. Varner
Brian Keith FoutchBrian Keith Foutch
Brian Keith Foutch
This study investigated the prevalence of depression and burnout symptoms among family medicine providers on active duty in the US Air Force. Results demonstrated that 84% of those surveyed scored positive for degrees of depression symptoms; only sex differences were significant.

1 January 2021 in Journal of Optometry
Verified
Journal Article
Open access
MWMolly R. Wilson
Molly R. Wilson
KSKyle A. Sandberg
Kyle A. Sandberg
Brian Keith FoutchBrian Keith Foutch
Brian Keith Foutch
There is robust evidence that higher macular pigment concentrations help reduce both veiling and discomfort glare in patients with or without ocular disease. We investigated whether there was also a relationship between macular pigment optical density (MPOD) and patient surveys about glare or ocular discomfort. We measured MPOD psychophysically in 23 healthy subjects and administered the National Eye Institute Visual Functioning Questionnaire (VFQ-25). Responses for each survey question were sorted from low (no limitation) to high (very severe limitation). The median response for each question was determined, and independent t-tests were performed on the mean MPOD values for survey responses above and below the median. We also performed a non-parametric correlation analysis between MPOD and survey responses. While the median response was “no limitation” for most (22 of 25) survey questions, responses were slightly higher for two questions concerning ocular discomfort and one question related to driving at night. MPOD levels were significantly higher in subjects that reported no discomfort in or around their eyes than in those that reported mild discomfort. There was also a trend toward higher MPOD levels in subjects who reported that pain in or around their eyes never limited their activity as well as in subjects who reported no difficulty driving at night. These preliminary findings are consistent with the well-established discomfort and glare hypotheses for MPOD. The current findings on subjective ocular discomfort in the absence of glare deserve further study.

11 April 2011 in Journal of Modern Optics
Verified
Journal Article
Closed access
Brian Keith FoutchBrian Keith Foutch
Brian Keith Foutch
JSJames M. Stringham
James M. Stringham
Vasudevan LakshminarayananVasudevan Lakshminarayanan
Vasudevan Lakshminarayanan
There are three variables involved in modeling measurement errors – type, severity, and selectivity. Whereas clinicians typically utilize a graphical technique to grade color deficiencies based on D-15 panel tests, Vingrys and King-Smith developed a quantitative scoring technique for panel color tests, which models all three factors by utilizing an overall moment of inertia for color difference vectors (CDVs) calculated in 1976 CIELUV space. We propose a least squares analysis via linear regression of the errors (ΔU, ΔV) according to the following equation: ΔV = mΔU, where m = slope of best-fit line determined by linear regression. Error type is determined by the angular proximity of the best-fit line to known confusion axes representing protan, deutan, tritan or unspecified color defects. The severity is the sum of the CDV lengths of all errors made, and the selectivity is determined by the adjusted variance of the least squares fit. We determined normative threshold values for type, severity and selectivity by inspecting 142 cap arrangements with tentative diagnoses. We then analyzed 49 standard D-15 cap arrangements of subjects with definitive diagnoses to determine the sensitivity and specificity of our method to defect types. The results were then compared with those of Vingrys and King-Smith. Our linear regression technique provides an improved assessment of error arrangements that represent subtle unspecified color defects. However, our model appears too sensitive to atypical repositioning errors made when the majority of errors lie along known confusions. Used in conjunction with previous quantitative methods, linear regression by least squares proves a useful tool in the classification of errors of D-15 color panel tests.